Non-invasive cardiac output monitoring device "ICON" in trauma patients: a feasibility study

被引:6
作者
Kuster, Matthias [1 ]
Haltmeier, Tobias [1 ]
Exadaktylos, Aristomenis [2 ]
Schnueriger, Beat [1 ]
机构
[1] Bern Univ Hosp, Dept Visceral & Transplant Surg, Div Acute Care Surg, CH-3010 Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Dept Emergency Med, Bern, Switzerland
关键词
Initial care; Emergency department; Non-invasive hemodynamic monitoring; Cardiac output; Trauma; ELECTRICAL VELOCIMETRY; BLUNT; CHILDREN;
D O I
10.1007/s00068-018-0984-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Assessment of hemodynamics is crucial for the evaluation of major trauma patients. Cardiac output (CO) monitoring provides additional information and may improve volume resuscitation. The goal of this prospective pilot study was to evaluate the feasibility of a new non-invasive CO monitoring (NICOM) device in the emergency department (ED). Methods: Single-center prospective observational pilot study including 20 trauma patients admitted to a level 1 trauma center. CO was continuously monitored for 60 min after ED admission using the new NICOM device ICON (R). This device measures changes of the thoracic bioimpedance to calculate CO. Conventional vital signs were recorded simultaneously. Feasibility, safety, reliability, user-friendliness, and impact of the device on standard ED procedures were assessed. Results: Thirteen (65%) patients were male, median age was 57.5 (IQR 25), and median ISS was 10.5 (IQR 14.8). Median CO over time was 9.8 l/min (IQR 4.6). No adverse effects were recorded. The device proved to be user-friendly with no negative impact on routine ED care. In four patients, detachment of electrodes was observed, and in four patients, the CO recording was temporary discontinued. Short-term changes of the CO were observed 44 times after the placement of electrodes and during patient transfers. Conclusions: Non-invasive CO monitoring proved to be feasible and safe for the initial hemodynamic evaluation of trauma patients. Problems with the NICOM device were detachment of electrodes and temporary signal loss. Due to the small sample size and relatively low injury burden of the patients included in this study, further prospective investigation is warranted.
引用
收藏
页码:1069 / 1076
页数:8
相关论文
共 25 条
[1]  
Bernstein DP, 2003, U.S. Patent, Patent No. [6511438, 6,511,438]
[2]   RELATIONSHIP BETWEEN SUPRANORMAL CIRCULATORY VALUES, TIME DELAYS, AND OUTCOME IN SEVERELY TRAUMATIZED PATIENTS [J].
BISHOP, MH ;
SHOEMAKER, WC ;
APPEL, PL ;
WO, CJ ;
ZWICK, C ;
KRAM, HB ;
MEADE, P ;
KENNEDY, F ;
FLEMING, AW .
CRITICAL CARE MEDICINE, 1993, 21 (01) :56-63
[3]   Noninvasive cardiac index monitoring in gunshot wound victims [J].
Bishop, MH ;
Shoemaker, WC ;
Shuleshko, J ;
Wo, CCJ .
ACADEMIC EMERGENCY MEDICINE, 1996, 3 (07) :682-688
[4]   Is noninvasive hemodynamic monitoring appropriate for the elderly critically injured patient? [J].
Brown, CVR ;
Shoemaker, WC ;
Wo, CCJ ;
Chan, L ;
Demetriades, D .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (01) :102-107
[5]  
Chamos C, 2013, PERIOPER MED-LONDON, V2, DOI 10.1186/2047-0525-2-19
[6]   Noninvasive Monitoring of the Autonomic Nervous System and Hemodynamics of Patients With Blunt and Penetrating Trauma [J].
Colombo, Joseph ;
Shoemaker, Withain C. ;
Belzberg, Howard ;
Hatzakis, George ;
Fathizadeh, Payman ;
Demetriades, Demetrios .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 65 (06) :1364-1373
[7]   Noninvasive Cardiac Output Determination: Broadening the Applicability of Hemodynamic Monitoring [J].
Compton, Friederike ;
Schaefer, Juergen-Heiner .
SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 13 (01) :44-55
[8]   Emergency department noninvasive (NICOM) cardiac outputs are associated with trauma activation, patient injury severity and host conditions and mortality [J].
Dunham, C. Michael ;
Chirichella, Thomas J. ;
Gruber, Brian S. ;
Ferrari, Jonathan P. ;
Martin, Joseph A. ;
Luchs, Brenda A. ;
Hileman, Barbara M. ;
Merrell, Renee .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (02) :479-485
[9]   Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: A feasibility study [J].
Flinck, Marianne ;
Graden, Asa ;
Milde, Helen ;
Flinck, Agneta ;
Hellstrom, Mikael ;
Bjork, Jonas ;
Nyman, Ulf .
ACTA RADIOLOGICA, 2010, 51 (08) :895-902
[10]   Impact of hemorrhage on trauma outcome: An overview of epidemiology, clinical presentations, and therapeutic considerations [J].
Kauvar, David S. ;
Lefering, Rolf ;
Wade, Charles E. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06) :S3-S9