Removal of Intrathecal Catheters Used in Drug Delivery Systems

被引:9
作者
Frizon, Leonardo A. [1 ]
Sabharwal, Navin C. [2 ]
Maiti, Tanmoy [1 ]
Golubovsky, Joshua [2 ]
May, Francis [2 ]
Shao, Jianning [2 ]
Machado, Andre G. [1 ]
Nagel, Sean J. [1 ]
机构
[1] Cleveland Clin, Neurol Inst, Ctr Neurol Restorat, Cleveland, OH 44106 USA
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH 44106 USA
来源
NEUROMODULATION | 2018年 / 21卷 / 07期
关键词
Catheter; complication; IDDS; intrathecal drug delivery systems; intrathecal pump; removal; BACLOFEN THERAPY; COMPLICATIONS; PAIN; MANAGEMENT; CANCER; ORIGIN;
D O I
10.1111/ner.12799
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
IntroductionImplanted intrathecal drug delivery systems (IDDS) are increasingly used in the treatment of spasticity and in patients with refractory pain. Literature discussing complications associated with intrathecal pump placement is widely available. However, reports of complications following the removal of chronically placed catheters are scarce. We reviewed our series of patients who had surgery to remove the intrathecal catheter. MethodsRetrospective review was performed for all patients who underwent surgery to remove a catheter linked to an IDDS between 2010 and 2016. Patients older than 18 years were included in final analysis. Demographic (including age at removal, sex, BMI, and comorbidities) and etiologic characteristics (indications of IDDS implant and explant, interval between implant and explant, and concomitant surgery) were analyzed. Simple logistic regression was performed to seek any potential predictor of complications. ResultsFifty-nine patients underwent removal of their intrathecal catheter after variable periods (mean interval of 189 months). On eight occasions, patients developed complications after catheter removal (mean interval between implant and explant was 76 months for these cases). Retained catheter was the cause of complications in half of these occasions. Persistent cerebrospinal fluid leak was the next most common complication, with requirement of an external ventricular drain and lumbar drain to facilitate wound healing on two separate occasions. ConclusionRemoval of an intrathecal catheter from IDDS systems may cause complications that in some cases require additional surgery.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 17 条
[1]   Long-term intrathecal baclofen therapy for severe spasticity of cerebral origin [J].
Albright, AL ;
Gilmartin, R ;
Swift, D ;
Krach, LE ;
Ivanhoe, CB ;
McLaughlin, JF .
JOURNAL OF NEUROSURGERY, 2003, 98 (02) :291-295
[2]   The Polyanalgesic Consensus Conference (PACC): Recommendations for Intrathecal Drug Delivery: Guidance for Improving Safety and Mitigating Risks [J].
Deer, Timothy R. ;
Pope, Jason E. ;
Hayek, Salim M. ;
Lamer, Tim J. ;
Veizi, Ilir Elias ;
Erdek, Michael ;
Wallace, Mark S. ;
Grider, Jay S. ;
Levy, Robert M. ;
Prager, Joshua ;
Rosen, Steven M. ;
Saulino, Michael ;
Yaksh, Tony L. ;
De Andres, Jose A. ;
Abejon Gonzalez, David ;
Vesper, Jan ;
Schu, Stefan ;
Simpson, Brian ;
Mekhail, Nagy .
NEUROMODULATION, 2017, 20 (02) :155-176
[3]   A prospective study of catheter-related complications of intrathecal drug delivery systems [J].
Follett, KA ;
Naumann, CP .
JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 2000, 19 (03) :209-215
[4]  
Hayek SM, 2011, PAIN PHYSICIAN, V14, P219
[5]  
Kurnutala Lakshmi N, 2015, Anesth Pain Med, V5, pe29786, DOI 10.5812/aapm.29786
[6]   Early outcomes after intrathecal baclofen therapy in ambulatory patients with multiple sclerosis [J].
Lee, Bryan S. ;
Jones, Jaes ;
Lang, Min ;
Achey, Rebecca ;
Dai, Lu ;
Lobel, Darlene A. ;
Nagel, Sean J. ;
Machado, Andre G. ;
Bethoux, Francois .
JOURNAL OF NEUROSURGERY, 2018, 129 (04) :1056-1062
[7]   Intracranial hemorrhage after removal of deep brain stimulation electrodes [J].
Liu, James K. C. ;
Soliman, Hesham ;
Machado, Andre ;
Deogaonkar, Milind ;
Rezai, Ali R. .
JOURNAL OF NEUROSURGERY, 2012, 116 (03) :525-528
[8]   Rate of Complications Following Spinal Cord Stimulation Paddle Electrode Removal [J].
Maldonado-Naranjo, Andres L. ;
Frizon, Leonardo A. ;
Sabharwal, Navin C. ;
Xiao, Roy ;
Hogue, Olivia ;
Lobel, Darlene A. ;
Machado, Andre G. ;
Nagel, Sean J. .
NEUROMODULATION, 2018, 21 (05) :513-519
[9]   Intracranial Migration of a Fractured Intrathecal Catheter From a Baclofen Pump System: Case Report and Analysis of Possible Causes [J].
Maugans, Todd A. .
NEUROSURGERY, 2010, 66 (02) :319-322
[10]   Comparison between an Ascenda and a silicone catheter in intrathecal baclofen therapy in pediatric patients: analysis of complications [J].
Motta, Francesco ;
Antonello, Clara Eleonora .
JOURNAL OF NEUROSURGERY-PEDIATRICS, 2016, 18 (04) :493-498