On-line solid-phase chelation for the determination of six metals in sea-water by inductively coupled plasma mass spectrometry

被引:21
作者
Sanchez Trujillo, I. [1 ]
Vereda Alonso, E. [1 ]
Siles Cordero, M. T. [1 ]
Cano Pavon, J. M. [1 ]
Garcia de Torres, A. [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; TRACE-METALS; FLOW-INJECTION; MULTIELEMENTAL DETERMINATION; ENVIRONMENTAL-SAMPLES; AMBERLITE XAD-4; NATURAL-WATERS; SILICA-GEL; ICP-MS; PRECONCENTRATION;
D O I
10.1039/b923156k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated low pressure flow analysis method with on-line column pre-concentration/inductively coupled plasma mass spectrometry (ICP-MS) was developed for the simultaneous determination of cobalt, chromium, cadmium, manganese, zinc and nickel in aqueous environmental samples. The system is based on cationic retention of the analytes onto a mini-column filled with silica gel functionalised with 1-(di-2-pyridyl)methylene thiocarbonohydrazide placed in the injection valve of a simple flow manifold. The effects of chemicals and flow variables were investigated. The optimized operating conditions, selected as a compromise between sensitivity and analytical frequency were: sample pH 8.6, sample flow rate of 1.4 mL min(-1), eluent flow rate of 1.3 mL min(-1), and eluent (HNO3) concentration of 2% (m/m). The relative standard deviation (n = 5), enrichment factor and linear working range were 0.3-4.0%, 2.3-32.9 and 0.02-60 mu g L-1, respectively. Detection limits (3 min sample loading time) were between 0.006 and 0.530 mu g L-1. The accuracy of the proposed method was checked with two certified reference materials (CRMs) of sea water SLEW 3 and NASS-5 and with two natural waters SLRS-4 and TMDA-54.4. Values obtained were in accordance with those reported for the certified materials. Recovery was found to be in the range of 93-110% for a suit of water samples with variable matrices (seawater and river water) collected in Malaga, Spain.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 40 条
[31]   Determination of 42 trace elements in seawater by inductively coupled plasma mass spectrometry after APDC chelate co-precipitation combined with iron [J].
Sun, Yali ;
Sun, Min .
ANALYTICAL LETTERS, 2007, 40 (12) :2391-2404
[32]   The application of ICP-SMS, GF-AAS and HG-AFS to the analysis of water and sediment samples from a temperate stratified estuary [J].
Townsend, AT ;
O'Sullivan, J ;
Featherstone, AM ;
Butler, ECV ;
Mackey, DJ .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (01) :113-120
[33]   Performance optimization of a commercially available iminodiacetate resin for the determination of Mn, Ni, Cu, Cd and Pb by on-line preconcentration inductively coupled plasma-mass spectrometry [J].
Warnken, KW ;
Tang, DG ;
Gill, GA ;
Santschi, PH .
ANALYTICA CHIMICA ACTA, 2000, 423 (02) :265-276
[34]   Improved immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber and application of the material to the determination of trace metals in seawater by inductively coupled plasma mass spectrometry [J].
Wen, B ;
Shan, X .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (05) :948-954
[35]   Preconcentration of trace elements in sea water with 8-hydroxyquinoline immobilized polyacrylonitrile hollow fiber membrane for determination by inductively coupled plasma-mass spectrometry [J].
Wen, B ;
Shan, XQ ;
Xu, SG .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 77 (02) :95-109
[36]   Determination of transition and rare earth elements in seawater by flow injection inductively coupled plasma time-of-flight mass spectrometry [J].
Willie, SN ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (09) :1707-1716
[37]  
YANG KL, 1999, J ANAL ATOM SPECTROM, V111, P139
[38]   Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using a manometer-sized alumina packed micro-column [J].
Yin, J ;
Jiang, ZC ;
Chang, G ;
Hu, B .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :333-339
[39]   Preconcentration and determination of trace metals in seawater using a thiol cotton fiber minicolumn coupled with inductively coupled plasma mass spectrometry [J].
Zhang, SZ ;
Lu, AX ;
Han, F ;
Shan, XQ .
ANALYTICAL SCIENCES, 2005, 21 (06) :651-654
[40]   Chelating sorbents based on silica gel and their application in atomic spectrometry [J].
Zougagh, M ;
Pavón, JMC ;
de Torres, AG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (06) :1103-1113