Performance evaluation of coherence-based adaptive imaging using clinical breast data

被引:42
作者
Wang, Shun-Li [1 ]
Chang, Chen-Han
Yang, Hsin-Chia
Chou, Yi-Hong
Li, Pai-Chi
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[2] Taipei Vet Gen Hosp, Dept Radiol, Taipei, Taiwan
[3] Natl Taiwan Univ, Grad Inst Biomed Elect & Bioinformat, Taipei, Taiwan
关键词
D O I
10.1109/TUFFC.2007.438
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Sound-velocity inhomogeneities degrade both the spatial resolution and the contrast in diagnostic ultrasound. We previously proposed an adaptive imaging approach based on the coherence of the data received in the channels of a transducer array, and we tested it on phantom data. In this study, the approach was tested on clinical breast data and compared with a correlation-based method that has been widely reported in the literature. The main limitations of the correlation-based method in ultrasonic breast imaging are the use of a near-field, phase-screen model and the integration errors due to the lack of a two-dimensional (2-D) array. In contrast, the proposed coherence-based method adaptively weights each image pixel based on the coherence of the receive-channel data. It does not make any assumption about the source of the focusing errors and has been shown to be effective using I-D arrays. This study tested its in vivo performance using clinical breast data acquired by a programmable system with a 5 MHz, 128-channel linear array. Twenty-five cases (6 fibroadenomas, 10 carcinomas, 6 cysts, and 3 abscesses) were investigated. Relative to nonweighted imaging, the average improvements in the contrast ratio and contrast-to-noise ratio for the coherence-based method were 8.57 dB and 23.2%, respectively. The corresponding improvements when using the correlation-based method were only 0.42 dB and 3.35%. In an investigated milk-of-calcium case, the improvement in the contrast was 4.47 dB and the axial and lateral dimensions of the object were reduced from 0.39 to 0.32 mm and from 0.51 to 0.43 mm, respectively. These results demonstrate the efficacy of the coherence-based method for clinical ultrasonic breast imaging using 1-D arrays.
引用
收藏
页码:1669 / 1679
页数:11
相关论文
共 24 条
[1]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767
[2]  
Gauss RC, 1999, ULTRASON, P1563, DOI 10.1109/ULTSYM.1999.849294
[3]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[4]   MEASUREMENT AND CORRECTION OF ULTRASONIC PULSE DISTORTION PRODUCED BY THE HUMAN BREAST [J].
HINKELMAN, LM ;
LIU, DL ;
WAAG, RC ;
ZHU, Q ;
STEINBERG, BD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1958-1969
[5]  
Hollman KW, 1999, ULTRASON, P1257, DOI 10.1109/ULTSYM.1999.849225
[6]   Improved estimation of phase aberration profiles [J].
Krishnan, S ;
Rigby, KW ;
ODonnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (03) :701-713
[7]   Adaptive compensation of phase and magnitude aberrations [J].
Krishnan, S ;
Li, PC ;
ODonnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (01) :44-55
[8]   Efficient parallel adaptive aberration correction [J].
Krishnan, S ;
Rigby, KW ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :691-703
[9]   Adaptive imaging using the generalized coherence factor [J].
Li, PC ;
Li, ML .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (02) :128-141
[10]   BLOCKED ELEMENT COMPENSATION IN PHASED-ARRAY IMAGING [J].
LI, PC ;
FLAX, SW ;
EBBINI, ES ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (04) :283-292