CVD diamond wafers as large-area thermoluminescence detectors for measuring the spatial distribution of dose

被引:10
作者
Marczewska, B
Bilski, P
Olko, P
Nesládek, M
Bergonzo, P
Rebisz, M
Waligórski, MPR
机构
[1] Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Univ Limburg, Inst Mat Res, Diepenbeek, Belgium
[3] CEA Saclay, SIAR, DIMRI, CEA Rech Technol,LIST, F-91191 Gif Sur Yvette, France
[4] Stanislaw Staszic Univ Min & Met, PL-30059 Krakow, Poland
[5] Ctr Oncol, Krakow, Poland
来源
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH | 2003年 / 199卷 / 01期
关键词
D O I
10.1002/pssa.200303811
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The applicability of large-area CVD diamond wafers (diameter about 5 cm, thickness about 0.1 mm), read out as thermoluminescence (TL) detectors, for assessing two-dimensional (2-D) dose distribution over their area, was investigated. To obtain 2-D TL images, a special TL reader equipped with large-area planchet and a CCD camera instead of the usual PM tube was developed. Several 2-D TL images: of an alpha source (Am-241), a Ra-226 needle source and a Ru-106 ophthalmic applicator, were measured and high-resolution digital images obtained. Our preliminary results demonstrate the potential capability of large-area CVD diamond wafers, read out as TL detectors, in 2-D dosimetry for medical applications. (C) 2003 WILEY-VCH Verlag GinbH & Co. KGaA, Weinheim.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 11 条
[1]   Miniature thermoluminescent detectors for dosimetry in radiotherapy [J].
Bilski, P ;
Waligórski, MPR ;
Budzanowski, M ;
Ochab, E ;
Olko, P .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :473-476
[2]   Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P [J].
Bilski, P .
RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) :199-206
[3]   Thermoluminescence characteristics of a new production of chemical vapour deposition diamond [J].
Furetta, C ;
Kitis, G ;
Brambilla, A ;
Jany, C ;
Bergonzo, P ;
Foulon, F .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :201-205
[4]   Fricke gel dosimetry in boron neutron capture therapy [J].
Gambarini, G ;
Birattari, C ;
Colombi, C ;
Pirola, L ;
Rosi, G .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :419-422
[5]   A diamond detector in the dosimetry of high-energy electron and photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2183-2192
[6]  
Marczewska B, 2002, PHYS STATUS SOLIDI A, V193, P470, DOI 10.1002/1521-396X(200210)193:3<470::AID-PSSA470>3.0.CO
[7]  
2-P
[8]   CVD diamonds as thermoluminescent detectors for medical applications [J].
Marczewska, B ;
Olko, P ;
Nesladek, M ;
Waligórski, MPR ;
Kerremans, Y .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :485-488
[9]   The use of radiographic firm for linear accelerator stereotactic radiosurgical dosimetry [J].
Robar, JL ;
Clark, BG .
MEDICAL PHYSICS, 1999, 26 (10) :2144-2150
[10]   Laser heating of thermoluminescent films: Dose mapping applied to beta dosimetry [J].
Setzkorn, R ;
Prevost, H ;
Gasiot, J ;
Christensen, P .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :419-422