Study on C-traveling wave fault location in neutral point non-effectively grounded system

被引:0
|
作者
Zheng, Q [1 ]
Yang, YH [1 ]
Qian, M [1 ]
Zhu, XK [1 ]
机构
[1] N China Elect Power Univ, Beijing 102206, Peoples R China
来源
2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2 | 2004年
关键词
non-effectively grounded system; C-Traveling wave fault location; wavelet; pattern recognition;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a new approach to the single-phase grounded fault location in a non-effectively grounded system. After the fault, the high-voltage impulse signal is injected at the beginning of the faulty line and the reflected traveling wave is obtained. In the context of known tine structure, the fault can be located by the analysis of the reflected traveling wave, i.e., C-traveling wave fault location. This method can not only calculate the electrical distance of the fault, but also determine the branch line that the fault lies in. Fault location with this method is irrelevant to the limits of the voltage phase in time of the fault, and can effectively overcome the impact of the grounded resistance. Experiments with physical model verify the correctness and practicability of the method.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [1] RESEARCH ON ADAPTIVE TRIPPING FOR SINGLE PHASE EARTH FAULT IN NEUTRAL POINT NON-EFFECTIVELY GROUNDED SYSTEM
    Xue, Yongduan
    Zhang, Qiufeng
    Wang, Zhenheng
    Xu, Bingyin
    Sun, Bo
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [2] Study on comprehensive line selection and continuous line selection for neutral point non-effectively grounded system
    Qi, Z
    Chen, JC
    Yang, YH
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 617 - 622
  • [3] Faulted Feeder Selection in Neutral Non-effectively Grounded Distribution System Using Single-phase Current Traveling Wave
    Shi, Shenxing
    Dong, Xinzhou
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1197 - 1203
  • [4] Rough Set Neural Network Based Fault Line Detection for Neutral Non-Effectively Grounded System
    Pang, Qingle
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 6550 - 6554
  • [5] Identification of ferromagnetic resonance fault in non-effectively grounded neutral system based on phase space reconstruction
    Guo, Cheng
    Chen, Bo
    Chen, Hui
    Yang, Lingrui
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (15): : 131 - 141
  • [6] Traveling-Wave Based Fault Location for Phase-to-Ground Fault in Non-Effectively Earthed Distribution Networks
    Wang, Yani
    Zheng, Tao
    Yang, Chang
    Yu, Li
    ENERGIES, 2020, 13 (19)
  • [7] Fault Location in Neutral Non-effectively Grounded Distribution Systems Using Phase Current and Line-to-line Voltage
    Tang, Jinrui
    Yin, Xianggen
    Wen, Minghao
    Zhang, Zhe
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (13) : 1371 - 1385
  • [8] A Single-phase Earth Fault Location Method Based on Transient Energy for Non-effectively Grounded System
    Wang X.
    Shi F.
    Zhang H.
    Xue J.
    Yun Z.
    Xie W.
    Ling P.
    Liu J.
    Dianwang Jishu/Power System Technology, 2019, 43 (03): : 818 - 825
  • [9] An improved Hausdorff distance method for locating single phase to ground fault in neutral non-effectively grounded system
    Wu, Wenhao
    Zhang, Xinhui
    Zhang, Jun
    He, Yu
    Bai, Wenyuan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (19) : 2747 - 2759
  • [10] Segment location for single-phase-to-ground fault in neutral non-effectively grounded system based on distributed electric-field measurement
    Xiao, Dongping
    He, Tao
    Xiao, Ruiyang
    Du, Xuefei
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184 (184)