Zirconia abutments and restorations: From laboratory to clinical investigations

被引:81
作者
Ferrari, M. [1 ]
Vichi, A. [1 ]
Zarone, F. [2 ]
机构
[1] Univ Siena, Dept Med Biotechnol, I-53100 Siena, Italy
[2] Univ Naples Federico II, Naples, Italy
关键词
Zirconia; Chipping; Zirconia abutments; Zirconia restorations; Ceramics; Metal-free; Clinical trials; In vitro; Mechanical properties; FIXED PARTIAL DENTURES; ALL-CERAMIC MATERIALS; LEAST; 5; YEARS; Y-TZP; BOND STRENGTH; FLEXURAL STRENGTH; COMPLICATION RATES; OBSERVATION PERIOD; FRACTURE LOAD; RESIN CEMENT;
D O I
10.1016/j.dental.2014.11.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In last years the use of zirconia in dentistry has become very popular. Unfortunately, the clinical indications for a dental use of zirconia are not completely clear yet, neither are their limitations. The objective of this review was to evaluate the basic science knowledge on zirconia and to discuss some aspects of the clinical behavior of zirconia-based restorations. In particular, one of the goals was highlighting the possible correlation between in vitro and in vivo studies. The definition of concepts like success, survival and failure was still debated and the correlation between in vitro results and predictability of clinical behavior was investigated. Published by Elsevier Ltd on behalf of Academy of Dental Materials. All rights reserved.
引用
收藏
页码:E63 / E76
页数:14
相关论文
共 186 条
[1]  
Aboushelib MN., J Prosthet Dent
[2]   Innovations in bonding to zirconia-based materials: Part I [J].
Aboushelib, Moustafa N. ;
Matinlinna, Jukka P. ;
Salameh, Ziad ;
Ounsi, Hani .
DENTAL MATERIALS, 2008, 24 (09) :1268-1272
[3]   Influence of crystal structure on debonding failure of zirconia veneered restorations [J].
Aboushelib, Moustafa N. ;
Wang, Hang .
DENTAL MATERIALS, 2013, 29 (07) :E97-E102
[4]   Innovations in bonding to zirconia-based materials. Part II: Focusing on chemical interactions [J].
Aboushelib, Moustafa N. ;
Mirmohamadi, Hesam ;
Matinlinna, Jukka P. ;
Kukk, Edwin ;
Ounsi, Hani F. ;
Salameh, Ziad .
DENTAL MATERIALS, 2009, 25 (08) :989-993
[5]   Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro [J].
Addi, S ;
Hedayati-Khams, A ;
Poya, A ;
Sjögren, G .
JOURNAL OF DENTISTRY, 2002, 30 (01) :53-58
[6]   Cement removal from restorations luted to titanium abutments with simulated subgingival margins [J].
Agar, JR ;
Cameron, SM ;
Hughbanks, JC ;
Parker, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (01) :43-47
[7]   Clinical trials in zirconia: a systematic review [J].
Al-Amleh, B. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (08) :641-652
[8]  
[Anonymous], 2014, IADR PER DUBR
[9]  
[Anonymous], CLIN ORAL IMPLANTS R
[10]  
[Anonymous], DENT MAT