Assessment of endoleak significance after endovascular repair of abdominal aortic aneurysms: A lumped parameter model

被引:10
作者
Wolters, B. J. B. M. [1 ]
Emmer, M. [1 ]
Rutten, M. C. M. [1 ]
Schurink, G. W. H. [2 ]
van de Vosse, F. N. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] Univ Hosp Maastricht, Dept Surg, Maastricht, Netherlands
关键词
abdominal aortic aneurysm; endoleak; intrasac pressure; experimental setup; computational model;
D O I
10.1016/j.medengphy.2006.11.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The outcome of endovascular repair of abdominal aortic aneurysms (AAAs) is greatly compromised by the possible occurrence of endoleak. Previously, the causes and effects of endoleak on a patient-specific basis have mainly been investigated in experimental studies. In order to both reconcile and physically substantiate the various experimental findings, a lumped parameter model of an incompletely excluded AAA was developed. After experimental validation, the model was applied to study the effects on the intrasac pressure of the degree of endoleak, the degree of stent-graft compliance, and the resistance of a possible outflow tract formed by a branching vessel. It is concluded that the presence of endoleak leads to elevated intrasac pressure, the mean of which is mainly governed by the outflow tract resistance, while the pulse pressure is governed by both the endoleak resistance and the stent-graft compliance. Based on the agreement of the current results with previous findings. it is further concluded that the lumped parameter modelling method provides a useful numerical tool for validating experimental endoleak studies. (C) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1106 / 1118
页数:13
相关论文
共 38 条
[11]   Endotension is influenced by wall compliance in a latex aneurysm model [J].
Gawenda, M ;
Knez, P ;
Winter, S ;
Jaschke, G ;
Wassmer, G ;
Schmitz-Rixen, T ;
Brunkwall, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (01) :45-50
[12]   Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair - An in vitro study [J].
Gawenda, M ;
Jaschke, G ;
Winter, S ;
Wassmer, G ;
Brunkwall, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (05) :501-505
[13]  
Idelchik I., 1994, Handbook of Hydraulic Resistance, V3rd
[14]  
McArdle W., 1996, Exercise Physiology: Energy, Nutrition, and Human Performance, V4th
[15]   Significance of endotension, endoleak, and aneurysm pulsatility after endovascular repair [J].
Mehta, M ;
Veith, FJ ;
Ohki, T ;
Lipsitz, EC ;
Cayne, NS ;
Darling, RC .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) :842-846
[16]   All sealed endoleaks are not the same:: A treatment strategy based on an ex-vivo analysis [J].
Mehta, M ;
Ohki, T ;
Veith, FJ ;
Lipsitz, EC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 21 (06) :541-544
[17]  
Milner Ross, 2004, Vascular, V12, P99, DOI 10.2310/6670.2004.20755
[18]  
Milnor WR., 1989, HEMODYNAMICS
[19]   A canine model to study the significance and hemodynamics of type II endoleaks [J].
Mousa, A ;
Dayal, R ;
Bernheim, J ;
Henderson, P ;
Hollenbeck, S ;
Trocciola, S ;
Prince, M ;
Gordon, R ;
Badimon, J ;
Fuster, V ;
Marin, ML ;
Kent, KC ;
Faries, PL .
JOURNAL OF SURGICAL RESEARCH, 2005, 123 (02) :275-283
[20]   Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions [J].
Olufsen, MS ;
Peskin, CS ;
Kim, WY ;
Pedersen, EM ;
Nadim, A ;
Larsen, J .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (11) :1281-1299