Rapid multiplanar abdominal survey using MRI with the steady-state free-precession technique

被引:7
作者
Dutka, Michael V. [1 ]
Bergin, Diane [1 ,2 ]
O'Kane, Patrick L. [1 ,2 ]
Frangos, Andrea J. [1 ]
Parker, Laurence [1 ]
Mitchell, Donald G. [1 ,2 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, MRI Div, Philadelphia, PA 19107 USA
关键词
steady-state free-precession (SSFP); MRI; abdomen; survey; rapid;
D O I
10.1002/jmri.21213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively evaluate the sensitivity, specificity, and positive and negative predictive values of steady-state free-precession (SSFP) survey MRI of the abdomen. Materials and Methods: A total of 375 consecutive outpatients underwent abdominal MRI at 1.5T. Excluding diffuse metastatic disease, 110 patients had at least one other clinically important finding. The SSFP survey included contiguous 5-mm-thick axial, sagittal, and coronal slices (total 90 slices) obtained during a total of 90 seconds of free breathing. Studies were reviewed by two experienced MRI readers independently, randomized, blinded, and at different sittings. The chi-squared test was used to compare SSFP to full MRI for showing clinically important findings. In a subset of 30 patients, confidence intervals (CI) were calculated to compare the accuracy of SSFP and full MRI as predictors of biopsy result. Results: SSFP detected 87.3% of clinically important findings and 93.3% of malignancies reported on the full MRI, with a 1.5% false-positive rate. Significant association was shown between SSFP and full MRI for clinically important findings (P < 0.0001). Compared to biopsy, accuracy of SSFP was high (85% +/- 12.7%), though not as high as full MRI (93.3% +/- 8.8%). Conclusion: SSFP provides a rapid survey of the abdomen, with good sensitivity and few false positives.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 30 条
[1]   Bedside teaching in the emergency department [J].
Aldeen, Amer Z. ;
Gisondi, Michael A. .
ACADEMIC EMERGENCY MEDICINE, 2006, 13 (08) :860-866
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]  
Black C, 2006, HEALTH TECHNOL ASSES, V10, pIII
[4]  
Brown David F M, 2002, Eur J Emerg Med, V9, P330
[5]   Steady-state preparation for spoiled gradient echo imaging [J].
Busse, RF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :653-661
[6]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[7]   Pulmonary embolism: Radiation dose with multi-detector row CT and digital angiography for diagnosis [J].
Coche, Emmanuel ;
Vynckier, Stefaan ;
Octave-Prignot, Michelle .
RADIOLOGY, 2006, 240 (03) :690-697
[8]   Radiology clinical synopsis: a simple solution for obtaining an adequate clinical history for the accurate reporting of imaging studies on patients in intensive care units [J].
Cohen, MD ;
Alam, K .
PEDIATRIC RADIOLOGY, 2005, 35 (09) :918-922
[9]   Screening applications for MRI in the detection of upper abdominal disease: comparative study of non-contrast-enhanced single-shot MRI and contrast-enhanced helical CT [J].
De Jaegere, T ;
Van Hoe, L ;
Van Steenbergen, W ;
Van Cutsem, E ;
Bosmans, H ;
Heindryckx, E ;
Loubeyre, P ;
Marchal, G .
EUROPEAN RADIOLOGY, 1999, 9 (05) :853-861
[10]  
Di Cesare Ernesto, 2003, Radiol Med, V105, P445