High-throughput single-cell manipulation system for a large number of target cells

被引:30
作者
Arakawa, Takahiro [1 ,2 ]
Noguchi, Masao [2 ]
Sumitomo, Keiko [3 ]
Yamaguchi, Yoshinori [3 ,4 ]
Shoji, Shuichi [2 ]
机构
[1] Tokyo Med & Dent Univ, Dept Biomed Devices & Instrumentat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[2] Waseda Univ, Shinjuku Ku, Tokyo 1698555, Japan
[3] Waseda Univ, Shinjuku Ku, Consolidated Res Inst Adv Sci & Med Care, Tokyo 1620041, Japan
[4] Osaka Univ, Grad Sch Engn, Photon Adv Res Ctr, Suita, Osaka 5650871, Japan
来源
BIOMICROFLUIDICS | 2011年 / 5卷 / 01期
基金
日本学术振兴会;
关键词
MICROFLUIDIC DEVICE; ELECTROPORATION; LYSIS; ARRAY; TRANSPORT;
D O I
10.1063/1.3567101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sequential and high-throughput single-cell manipulation system for a large volume of cells was developed and the successive manipulation for single cell involving single-cell isolation, individual labeling, and individual rupture was realized in a microhydrodynamic flow channel fabricated by using two-dimensional simple flow channels. This microfluidic system consisted of the successive single-cell handlings of single-cell isolation from a large number of cells in cell suspension, labeling each isolated single cell and the lysate extraction from each labeled single cell. This microfluidic system was composed of main channels, cell-trapping pockets, drain channels, and single-cell content collection channels which were fabricated by polydimethylsiloxane. We demonstrated two kinds of prototypes for sequential single-cell manipulations, one was equipped with 16 single-cell isolation pockets in microchannel and the other was constructed of 512 single-cell isolation pockets. In this study, we demonstrated high-throughput and high-volume single-cell isolation with 512 pocket type device. The total number of isolated single cells in each isolation pocket from the cell suspension at a time was 426 for the cell line of African green monkey kidney, COS-1, and 360 for the rat primary brown preadipocytes, BAT. All isolated cells were stained with fluorescence dye injected into the same microchannel successfully. In addition, the extraction and collection of the cell contents was demonstrated using isolated stained COS-1 cells. The cell contents extracted from each captured cell were individually collected within each collection channel by local hydrodynamic flow. The sequential trapping, labeling, and content extraction with 512 pocket type devices realized high-throughput single-cell manipulations for innovative single-cell handling, feasible staining, and accurate cell rupture. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3567101]
引用
收藏
页数:11
相关论文
共 30 条
  • [1] Three-dimensional sheath flow sorting microsystem using thermosensitive hydrogel
    Arakawa, Takahiro
    Shirasaki, Yoshitaka
    Aoki, Tokihiko
    Funatsu, Takashi
    Shoji, Shuichi
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 135 (01) : 99 - 105
  • [2] High-speed particles and biomolecules sorting microsystem using thermosensitive hydrogel
    Arakawa, Takahiro
    Shirasaki, Yoshitaka
    Izumi, Toshimitsu
    Aoki, Tokihiko
    Sugino, Hirokazu
    Funatsu, Takashi
    Shoji, Shuichi
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (12) : 3141 - 3146
  • [3] Single-cell microbiology: Tools, technologies, and applications
    Brehm-Stecher, BF
    Johnson, EA
    [J]. MICROBIOLOGY AND MOLECULAR BIOLOGY REVIEWS, 2004, 68 (03) : 538 - +
  • [4] Dynamic single cell culture array
    Di Carlo, Dino
    Wu, Liz Y.
    Lee, Luke P.
    [J]. LAB ON A CHIP, 2006, 6 (11) : 1445 - 1449
  • [5] Cells on chips
    El-Ali, Jamil
    Sorger, Peter K.
    Jensen, Klavs F.
    [J]. NATURE, 2006, 442 (7101) : 403 - 411
  • [6] Single cell manipulation, analytics, and label-free protein detection in microfluidic devices for systems nanobiology
    Hellmich, W
    Pelargus, C
    Leffhalm, K
    Ros, A
    Anselmetti, D
    [J]. ELECTROPHORESIS, 2005, 26 (19) : 3689 - 3696
  • [7] Transport, location, and quantal release monitoring of single cells on a microfluidic device
    Huang, WH
    Cheng, W
    Zhang, Z
    Pang, DW
    Wang, ZL
    Cheng, JK
    Cui, DF
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (02) : 483 - 488
  • [8] On-chip single-cell lysis for extracting intracellular material
    Ikeda, Norifumi
    Tanaka, Nobuaki
    Yanagida, Yasuko
    Hatsuzawa, Takeshi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (9B): : 6410 - 6414
  • [9] Cell handling using microstructured membranes
    Irimia, D
    Toner, M
    [J]. LAB ON A CHIP, 2006, 6 (03) : 345 - 352
  • [10] Single-cell chemical lysis in picoliter-scale closed volumes using a microfabricated device
    Irimia, D
    Tompkins, RG
    Toner, M
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (20) : 6137 - 6143