Urinary albumin excretion in healthy adults: a cross sectional study of 24-hour versus timed overnight samples and impact of GFR and other personal characteristics

被引:11
作者
Fagerstrom, Peter [1 ]
Sallsten, Gerd [1 ]
Akerstrom, Magnus [1 ]
Haraldsson, Borje [2 ]
Barregard, Lars [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Occupat & Environm Med, S-40530 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Mol & Clin Med, S-40530 Gothenburg, Sweden
关键词
Glomerular filtration rate; Urinary albumin; Timed urine samples; 24-hour samples; Overnight samples; 1ST MORNING VOIDS; CREATININE RATIO; BLOOD-PRESSURE; ALBUMIN/CREATININE RATIO; PROTEIN EXCRETION; FILTRATION-RATE; MICROALBUMINURIA; COLLECTIONS; VARIABILITY; HYPERTENSION;
D O I
10.1186/1471-2369-16-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Urinary albumin can be measured in 24 h or spot samples. The 24 h urinary albumin excretion rate is considered the gold standard, but is cumbersome to collect. Instead, often an overnight sample is collected, and adjusted for dilution. Proxies for 24 h excretion rate have been studied in diabetics, but seldom in healthy individuals. Our aims were to compare 24 h and overnight albumin excretion, to assess the impact of personal characteristics, and to examine correlations between the 24 h excretion rate and proxies such as the albumin to creatinine ratio (ACR). Methods: Separate 24 h and overnight urine samples were collected from 152 healthy kidney donors. Urinary creatinine, specific gravity, collection time, and sample volume determined. Differences between 24 h and overnight samples were examined, and the effects of age, sex, smoking, body mass, glomerular filtration rate, and urinary flow rate were assessed. Results: The 24 h albumin excretion rate and ACR were both significantly higher than their overnight counterparts. Unadjusted albumin was unsurprisingly higher in the more concentrated overnight samples, while concentrations adjusted for specific gravity were similar. In multivariate analysis, the 24 h excretion rate and proxies were positively associated with glomerular filtration rate, as was ACR in overnight samples. There were positive associations between urinary albumin and body mass. Conclusions: Proxies for the 24 h albumin excretion rate showed relatively high correlations with this gold standard, but differences due to sampling period, adjustment method, and personal characteristics were large enough to be worth considering in studies of albumin excretion in healthy individuals.
引用
收藏
页数:9
相关论文
共 50 条
[1]   Variability of urinary cadmium excretion in spot urine samples, first morning voids, and 24 h urine in a healthy non-smoking population: Implications for study design [J].
Akerstrom, Magnus ;
Barregard, Lars ;
Lundh, Thomas ;
Sallsten, Gerd .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2014, 24 (02) :171-179
[2]   Sampling of urinary cadmium: differences between 24-h urine and overnight spot urine sampling, and impact of adjustment for dilution [J].
Akerstrom, Magnus ;
Lundh, Thomas ;
Barregard, Lars ;
Sallsten, Gerd .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2012, 85 (02) :189-196
[3]   Low-grade albuminuria and incidence of cardiovascular disease events in nonhypertensive and nondiabetic individuals -: The Framingham heart study [J].
Ärnlöv, J ;
Evans, JC ;
Meigs, JB ;
Wang, TJ ;
Fox, CS ;
Levy, D ;
Benjamin, EJ ;
D'Agostino, RB ;
Vasan, RS .
CIRCULATION, 2005, 112 (07) :969-975
[4]   Detection of microalbuminuria - Receiver operating characteristic curve analysis favors albumin-to-creatinine ratio over albumin concentration [J].
Bakker, AJ .
DIABETES CARE, 1999, 22 (02) :307-313
[5]   Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources [J].
Barregard, Lars ;
Fabricius-Lagging, Elisabeth ;
Lundh, Thomas ;
Molne, Johan ;
Wallin, Maria ;
Olausson, Michael ;
Modigh, Cecilia ;
Sallsten, Gerd .
ENVIRONMENTAL RESEARCH, 2010, 110 (01) :47-54
[6]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[7]  
Carrieri M, 2001, INT ARCH OCC ENV HEA, V74, P63
[8]   Low muscular mass and overestimation of microalbuminuria by urinary albumin/creatinine ratio [J].
Cirillo, M ;
Laurenzi, M ;
Mancini, M ;
Zanchetti, A ;
De Santo, NG .
HYPERTENSION, 2006, 47 (01) :56-61
[9]   Microalbuminuria in nondiabetic adults - Relation of blood pressure, body mass index, plasma cholesterol levels, and smoking: The Gubbio Population Study [J].
Cirillo, M ;
Senigalliesi, L ;
Laurenzi, M ;
Alfieri, R ;
Stamler, J ;
Stamler, R ;
Panarelli, W ;
De Santo, NG .
ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (17) :1933-1939
[10]   1ST MORNING URINARY ALBUMIN CONCENTRATION IS A GOOD PREDICTOR OF 24-HOUR URINARY ALBUMIN EXCRETION IN CHILDREN WITH TYPE-1 (INSULIN-DEPENDENT) DIABETES [J].
COWELL, CT ;
ROGERS, S ;
SILINK, M .
DIABETOLOGIA, 1986, 29 (02) :97-99