Cementless total hip arthroplasty: a review

被引:9
作者
Diehl, Peter [1 ]
Haenle, Maximilian [1 ]
Bergsehmidt, Philipp [1 ]
Gollwitzer, Hans [2 ]
Schauwecker, Johannes
Bader, Rainer
Mittelmeier, Wolfram [1 ]
机构
[1] Univ Rostock, Orthopad Klin & Poliklin, Rostock, Germany
[2] Tech Univ Munich, Klin Orthopad & Unfallchirurg, Munich, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2010年 / 55卷 / 05期
关键词
cementless; material; total hip replacement; wear; SURFACE REPLACEMENT ARTHROPLASTY; JOINT RESURFACE ARTHROPLASTY; TOTAL KNEE ARTHROPLASTY; PRESS-FIT CUP; FOLLOW-UP; ACETABULAR COMPONENT; FEMORAL COMPONENT; FIXATION PRINCIPLES; BONE-CEMENT; PART;
D O I
10.1515/BMT.2010.037
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of total hip replacement (THR) is the restoration of a painless functioning hip joint with the main focus on the biomechanical properties. Advances in surgical techniques and biomaterial properties currently allow predictable surgical results in most patients. Despite the overwhelming success of this surgical procedure, the debate continues surrounding the optimal choice of implants and fixation. Femoral and acetabular implants with varying geometries and fixation methods are currently available. Problems inherent with acrylic bone cement, however, have encouraged surgeons to use alternative surfaces to allow biologic fixation. Optimal primary and secondary fixation of cementless hip stems is a precondition for long-term stability. Important criteria to achieve primary stability are good rotational and axial stability by press-fit fixation. The objective of the cementless secondary fixation is the biological integration of the implant by bony ingrowth. Nevertheless, current investigations show excellent results of cementless fixation even in older patients with reduced osseous quality. The main advantages of cementless fixation include biological integration, reduced duration of surgery, no tissue damage by cement polymerization and reduction of intraoperative embolisms. In comparison to cemented THR both, cementless sockets and stems provide good long-term results.
引用
收藏
页码:251 / 264
页数:14
相关论文
共 95 条
[51]  
Morscher E, 1993, Acta Orthop Belg, V59 Suppl 1, P260
[52]  
MORSCHER E, 1989, CLIN ORTHOP RELAT R, P12
[53]   Clinical and radiographic results of cementless AML total hip arthroplasty in young patients [J].
Nercessian, OA ;
Wu, WH ;
Sarkissian, H .
JOURNAL OF ARTHROPLASTY, 2001, 16 (03) :312-316
[54]   On the secondary stability of coated cementless hip replacement: parameters that affected interface strength [J].
Orlik, J ;
Zhurov, A ;
Middleton, J .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) :825-831
[55]   Two-incision THA had modest outcomes and some substantial complications [J].
Pagnano, MW ;
Leone, J ;
Lewallen, DG ;
Hanssen, AD .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :86-90
[56]   Cementless total hip arthroplasty in patients older than 80 years of age [J].
Pieringer, H ;
Labek, G ;
Auersperg, V ;
Böhler, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05) :641-645
[57]  
Pipino F., 2000, The Italian Journal of Ortophaedics and Traumatology, V1, P31
[58]   Primary rotatory stability of robot-assisted and manually implanted hip endoprosthesis stems [J].
Prymka M. ;
Vogiatzis M. ;
Hassenpflug J. .
Der Unfallchirurg, 2004, 107 (4) :285-293
[59]  
RACEY SN, 2004, EUR CELL MAT S1, V7, P81
[60]   Fabrication methods of porous metals for use in orthopaedic applications [J].
Ryan, G ;
Pandit, A ;
Apatsidis, DP .
BIOMATERIALS, 2006, 27 (13) :2651-2670