Comparison of gas chromatography-combustion-mass spectrometry and gas chromatography-flame ionization detector for the determination of fatty acid methyl esters in biodiesel without specific standards

被引:15
作者
Alonso Sobrado, Laura [1 ]
Freije-Carrelo, Laura [1 ]
Moldovan, Mariella [1 ]
Ruiz Encinar, Jorge [1 ]
Garcia Alonso, J. Ignacio [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, Julian Claveria 8, E-33006 Oviedo, Spain
关键词
GC-combustion-MS; GC-FID; Internal standard; Absolute quantification; FAMEs; Biodiesel; LACKING AUTHENTIC STANDARDS; QUANTIFICATION; BLENDS;
D O I
10.1016/j.chroma.2016.06.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
GC-FID has been effectively used as a universal quantification technique for volatile organic compounds for a long time. In most cases, the use of the ECN allows for quantification by GC-FID without external calibration using only the response of a single internal standard. In this paper we compare the performance characteristics of GC-FID with those of post-column C-13 Isotope Dilution GC-Combustion-MS for the absolute quantification of organic compounds without the need for individual standards. For this comparison we have selected the quantification of FAMEs in biodiesel. The selection of the right internal standard was critical for GC-FID even when ECN were considered. On the other hand, the nature of the internal standard was not relevant when GC-Combustion-MS was employed. The proposed method was validated with the analysis of the certified reference material SRM 2772 and comparative data was obtained on real biodiesel samples. The analysis of the SRM 2772 biodiesel provided recoveries in the range 100.6-103.5% and 96.4-103.6% for GC-combustion-MS and GC-FID, respectively. The detection limit for GC-combustion-MS was found to be 4.2 ng compound/g of injected sample. In conclusion, the quantitative performance of GC-Combustion-MS compared satisfactorily with that of GC-FID constituting a viable alternative for the quantification of organic compounds without the need for individual standards. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 21 条
[1]   Modification of a commercial gas chromatography isotope ratio mass spectrometer for on-line carbon isotope dilution: Evaluation of its analytical characteristics for the quantification of organic compounds [J].
Alonso Sobrado, Laura ;
Robledo Fernandez, Mario ;
Cueto Diaz, Sergio ;
Ruiz Encinar, Jorge ;
Garcia Alonso, J. Ignacio .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1419 :99-108
[2]  
Andersson J.T., 2014, PRACTICAL GAS CHROMA, P205
[3]  
[Anonymous], 141032003 EN
[4]  
[Anonymous], 2012, GUID STAND METH PERF
[5]  
[Anonymous], 141032011 EN
[6]  
ASTM, ASTM D6751
[7]   Gas Chromatography-Combustion-Mass Spectrometry with Postcolumn Isotope Dilution for Compound-Independent Quantification: Its Potential to Assess HS-SPME Procedures [J].
Cueto Diaz, Sergio ;
Ruiz Encinar, Jorge ;
Sanz-Medel, Alfredo ;
Garcia Alonso, J. Ignacio .
ANALYTICAL CHEMISTRY, 2010, 82 (16) :6862-6869
[8]   A Quantitative Universal Detection System for Organic Compounds in Gas Chromatography with Isotopically Enriched 13CO2 [J].
Cueto Diaz, Sergio ;
Ruiz Encinar, Jorge ;
Sanz-Medel, Alfredo ;
Garcia Alonso, J. Ignacio .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (14) :2561-2564
[9]  
Dettmer-Wilde K., 2014, Practical Gas Chromatography: A Comprehensive Reference, P271, DOI DOI 10.1007/978-3-642-54640-2_8
[10]  
EN, EN 14214