Dosimetric comparison of RapidPlan and manually optimised volumetric modulated arc therapy plans in prostate cancer

被引:2
作者
Chua, Loyce M. H. [1 ,2 ]
Pang, Eric P. P. [1 ]
Master, Zubin [1 ]
Sultana, Rehena [3 ]
Tuan, Jeffrey K. L. [1 ,3 ]
Bragg, Christopher M. [2 ]
机构
[1] Natl Canc Ctr Singapore, Div Radiat Oncol, 11 Hosp Crescent, Singapore 169610, Singapore
[2] Sheffield Hallam Univ, Fac Hlth & Wellbeing, Sheffield, S Yorkshire, England
[3] Duke NUS Med Sch, Singapore, Singapore
关键词
dosimetry; prostate VMAT; radiotherapy treatment planning; RapidPlan; KNOWLEDGE-BASED IMRT; QUALITY; LUNG; VALIDATION; PLANNERS; DELIVERY; CENTERS; RISK; HEAD;
D O I
10.1017/S1460396920000345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate whether RapidPlan (RP) could generate clinically acceptable prostate volumetric modulated arc therapy (VMAT) plans. Methods: The in-house RP model was used to generate VMAT plans for 50 previously treated prostate cancer patients, with no additional optimisation being performed. The VMAT plans that were generated using the RP model were compared with the patients' previous, manually optimised clinical plans (MP), none of which had been used for the development of the in-house RP prostate model. Differences between RP and MP in planning target volume (PTV) doses, organs at risk (OAR) sparing, monitor units (MU) and planning time required to produce treatment plans were analysed. Assessment of PTV doses was based on the conformation number (CN), homogeneity index (HI), D-2%, D-99% and the mean dose of the PTV. The OAR doses evaluated were the rectal V-50 Gy, V-65 Gy, V-70 Gy and the mean dose, the bladder V-65 Gy, V-70 Gy and the mean dose, and the mean dose to both femurs. Results: D-99% and mean dose of the PTV were lower for RP than for MP (p = 0.006 and p = 0.040, respectively).V-50 Gy, V-65 Gy and the mean dose to rectum were lower in RP than in MP (p < 0.001). V-65 Gy, V-70 Gy and the mean dose to bladder were lower in RP than in MP (p < 0.001). RP had enhanced the sparing of both femurs (p < 0.001) and significantly reduced the planning time to less than 5% of the time taken with MP. MU in RP was significantly higher than MP by an average of 52.5 MU (p < 0.001) and 46 out of the 50 RP plans were approved by the radiation oncologist. Conclusion: This study has demonstrated that VMAT plans generated using an in-house RP prostate model in a single optimisation for prostate patients were clinically acceptable with comparable or better plan quality compared to MP. RP can add value and improve treatment planning efficiency in a high-throughput radiotherapy department through reduced plan optimisation time while maintaining consistency in the plan quality.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 37 条
  • [1] Predicting dose-volume histograms for organs-at-risk in IMRT planning
    Appenzoller, Lindsey M.
    Michalski, Jeff M.
    Thorstad, Wade L.
    Mutic, Sasa
    Moore, Kevin L.
    [J]. MEDICAL PHYSICS, 2012, 39 (12) : 7446 - 7461
  • [2] Knowledge-based treatment planning: An inter-technique and inter-system feasibility study for prostate cancer
    Cagni, Elisabetta
    Botti, Andrea
    Micera, Renato
    Galeandro, Maria
    Sghedoni, Roberto
    Orlandi, Matteo
    Iotti, Cinzia
    Cozzi, Luca
    Iori, Mauro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 38 - 45
  • [3] Knowledge-based IMRT treatment planning for prostate cancer
    Chanyavanich, Vorakarn
    Das, Shiva K.
    Lee, William R.
    Lo, Joseph Y.
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2515 - 2522
  • [4] Can all centers plan intensity-modulated radiotherapy (IMRT) effectively? An external audit of dosimetric comparisons between three-dimensional conformal radiotherapy and IMRT for adjuvant chemoradiation for gastric cancer
    Chung, Hans T.
    Lee, Brian
    Park, Eileen
    Lu, Jiade J.
    Xia, Ping
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1167 - 1174
  • [5] Craft DL., 2012, INT J RADIAT ONCOL, V82, pE83, DOI 10.1016/j.ijrobp.2010.12.007
  • [6] Intensity-modulated radiation therapy dose prescription, recording, and delivery: Patterns of variability among institutions and treatment planning systems
    Das, Indra J.
    Cheng, Chee-Wai
    Chopra, Kashmiri L.
    Mitra, Raj K.
    Srivastava, Shiv P.
    Glatstein, Eli
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2008, 100 (05): : 300 - 307
  • [7] A broad scope knowledge based model for optimization of VMAT in esophageal cancer: validation and assessment of plan quality among different treatment centers
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Laksar, Sarbani
    Tozzi, Angelo
    Scorsetti, Marta
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [8] On the pre-clinical validation of a commercial model-based optimisation engine: Application to volumetric modulated arc therapy for patients with lung or prostate cancer
    Fogliata, Antonella
    Belosi, Francesca
    Clivio, Alessandro
    Navarria, Piera
    Nicolini, Giorgia
    Scorsetti, Marta
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 385 - 391
  • [9] Assessment of a model based optimization engine for volumetric modulated arc therapy for patients with advanced hepatocellular cancer
    Fogliata, Antonella
    Wang, Po-Ming
    Belosi, Francesca
    Clivio, Alessandro
    Nicolini, Giorgia
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2014, 9 : 236
  • [10] A Knowledge-Based Approach to Improving and Homogenizing Intensity Modulated Radiation Therapy Planning Quality Among Treatment Centers: An Example Application to Prostate Cancer Planning
    Good, David
    Lo, Joseph
    Lee, W. Robert
    Wu, Q. Jackie
    Yin, Fang-Fang
    Das, Shiva K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (01): : 176 - 181