A new step in high-frequency EPR of defects in semiconductors

被引:2
作者
Blok, H
Disselhorst, JAJM
Orlinskii, SB
Schmidt, J
Baranov, PG
机构
[1] Leiden Univ, Dept Mol Phys, Huygens Lab, NL-2300 RA Leiden, Netherlands
[2] RAS, AF Ioffe Phys Tech Inst, St Petersburg 194021, Russia
关键词
EPR; ESE; high field; high-frequency; mm-wave;
D O I
10.1016/j.physb.2003.09.100
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
An electron paramagnetic resonance (EPR) spectrometer is described which allows for continuous-wave and pulsed EPR experiments at 275 GHz (wavelength 1.1 mm). The related magnetic field of 9.9 T for g similar to 2 is supplied by a superconducting solenoid. The microwave bridge employs quasi-optical as well as conventional waveguide components. A cylindrical, single-mode cavity provides a high filling factor and a high sensitivity for EPR detection. Even with the available microwave power of 1 mW incident at the cavity a high microwave magnetic field B, is obtained of about 0.1 mT which permits pi/2-pulses as short as 100 ns. The performance of the spectrometer is illustrated with the help of spectra taken with several samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1147 / 1150
页数:4
相关论文
共 9 条
  • [1] Budil DE, 1989, ADV EPR APPL BIOL BI
  • [2] Far-infrared electron-paramagnetic-resonance spectrometer utilizing a quasioptical reflection bridge
    Earle, KA
    Tipikin, DS
    Freed, JH
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (07) : 2502 - 2513
  • [3] EARLE KA, 1996, ADV MAGNETIC OPTICAL, V19
  • [4] New technologies in electron spin resonance
    Freed, JH
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 2000, 51 (51) : 655 - 689
  • [5] A high-field/high-frequency heterodyne induction-mode electron paramagnetic resonance spectrometer operating at 360 GHz
    Fuchs, MR
    Prisner, TF
    Mobius, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09) : 3681 - 3683
  • [6] GRINBERG OY, 2003, VERY HIGH FREQUENCY, V22
  • [7] Ultrawide band multifrequency high-field EMR technique: A methodology for increasing spectroscopic information
    Hassan, AK
    Pardi, LA
    Krzystek, J
    Sienkiewicz, A
    Goy, P
    Rohrer, M
    Brunel, LC
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (02) : 300 - 312
  • [8] High-Field/High-Frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    Rohrer, M
    Brügmann, O
    Kinzer, B
    Prisner, TF
    [J]. APPLIED MAGNETIC RESONANCE, 2001, 21 (3-4) : 257 - 274
  • [9] Quasi-optical cw mm-wave electron spin resonance spectrometer
    Smith, GM
    Lesurf, JCG
    Mitchell, RH
    Riedi, PC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) : 3924 - 3937