EXPERIMENTAL VERIFICATION OF GAMMA-EFFICIENCY CALCULATIONS FOR SCINTILLATION DETECTORS IN ANGLE 4 SOFTWARE

被引:35
作者
Thabet, Abouzeid A. [1 ]
Dlabac, Aleksandar D. [2 ]
Jovanovic, Slobodan I. [2 ,3 ]
Badawi, Mohamed S. [4 ]
Mihaljevic, Nikola N. [2 ,5 ]
El-Khatib, Ahmed M. [4 ]
Gouda, Mona M. [4 ]
Abbas, Mahmoud I. [4 ]
机构
[1] Pharos Univ, Fac Allied Med Sci, Dept Med Equipment Technol, Alexandria, Egypt
[2] Univ Montenegro, Ctr Nucl Competence & Knowledge Management, Podgorica, Montenegro
[3] Univ Montenegro, Fac Math & Nat Sci, Dept Phys, Podgorica, Montenegro
[4] Univ Alexandria, Fac Sci, Dept Phys, Alexandria, Egypt
[5] Univ Montenegro, Maritime Fac, Dept Math, Kotor, Montenegro
关键词
gamma spectrometry; scintillation detector; efficiency calculation; ANGLE software; experimental verification; ENERGY PEAK EFFICIENCY; GERMANIUM DETECTOR; RAY DETECTORS; CALIBRATION; ALGORITHM; MATRIX; CODE; GE;
D O I
10.2298/NTRP1501035T
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
ANGLE software for semiconductor detector efficiency calculations - long existing and widely accepted tool in quantitative gamma spectrometry - has been recently extended to scintillation Nail detectors. The extension features in the latest edition (ANGLE 4) and it is briefly outlined. Discretization of reference efficiency curve, meaning possibility of using ANGLE 4 for particular gamma energies without constructing the complete reference efficiency curve, is particularly emphasized. This yields both in enhanced practicality and higher accuracy, while reducing the potential for systematic errors. The present work is primarily focussed on experimental verification of ANGLE 4 for Nail detectors. Two detectors (2 x 2 and 3 x 3 inches) were employed in the experiment. Commercially calibrated gamma sources (in the forms of quasi point and cylinder) and homemade solutions (diluted from calibrated ones) were measured at various distances from the detector(s), ranging 0 cm to 50 cm. Energy range observed was 59 keV to 1408 keV. Versatility of counting conditions, in terms of detectors and sources used, gamma energies observed, source detector separations, etc., was aimed at creating as large experimental evidence as possible for verification purposes. Experimentally obtained efficiencies are compared with those calculated by ANGLE 4. Very good agreement is obtained - well within the experimental uncertainties - thus proving the reliability of the software.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 39 条
[1]   Reliability of two calculation codes for efficiency calibrations of HPGe detectors [J].
Abbas, K ;
Simonelli, F ;
D'Alberti, F ;
Forte, M ;
Stroosnijder, MF .
APPLIED RADIATION AND ISOTOPES, 2002, 56 (05) :703-709
[2]   Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method [J].
Abbas, Mahmoud I. ;
Badawi, M. S. ;
Ruskov, I. N. ;
El-Khatib, A. M. ;
Grozdanov, D. N. ;
Thabet, A. A. ;
Kopatch, Yu. N. ;
Gouda, M. M. ;
Skoy, V. R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 :110-114
[3]  
[Anonymous], ANGLE SOFTWARE
[4]   A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio [J].
Badawi, M. S. ;
Ruskov, I. ;
Gouda, M. M. ;
El-Khatib, A. M. ;
Alotiby, M. F. ;
Mohamed, M. M. ;
Thabet, A. A. ;
Abbas, M. I. .
JOURNAL OF INSTRUMENTATION, 2014, 9
[5]   New numerical simulation approach to calibrate the NaI(Tl) detectors array using non-axial extended spherical sources [J].
Badawi, M. S. ;
El-Khatib, A. M. ;
Krar, M. E. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[6]   An approach to evaluate the efficiency of γ-ray detectors to determine the radioactivity in environmental samples [J].
Badawi, Mohamed. S. ;
El-Khatib, Ahmed M. ;
Diab, Samah. M. ;
Nafee, Sherif. S. ;
El-Mallah, Ekram. A. .
CHINESE PHYSICS C, 2014, 38 (06)
[7]   A NEW MATHEMATICAL MODEL FOR DETERMINING FULL-ENERGY PEAK EFFICIENCY OF AN ARRAY OF TWO GAMMA DETECTORS COUNTING RECTANGULAR PARALLELEPIPED SOURCES [J].
Badawi, Mohamed S. ;
Krar, Mohamed E. ;
El-Khatib, Ahmed M. ;
Jovanovic, Slobodan I. ;
Dlabac, Aleksandar D. ;
Mihaljevic, Nikola N. .
NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04) :370-380
[8]   An empirical formula to calculate the full energy peak efficiency of scintillation detectors [J].
Badawi, Mohamed S. ;
Abd-Elzaher, Mohamed ;
Thabet, Abouzeid A. ;
El-khatib, Ahmed M. .
APPLIED RADIATION AND ISOTOPES, 2013, 74 :46-49
[9]   New algorithm for studying the effect of self attenuation factor on the efficiency of γ-rays detectors [J].
Badawi, Mohamed S. ;
Gouda, Mona M. ;
Nafee, Sherif S. ;
El-Khatib, Ahmed M. ;
El-Mallah, Ekram A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 696 :164-170
[10]   New analytical approach to calibrate the co-axial HPGe detectors including correction for source matrix self-attenuation [J].
Badawi, Mohamed S. ;
Gouda, Mona M. ;
Nafee, Sherif S. ;
El-Khatib, Ahmed M. ;
El-Mallah, Ekram A. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (12) :2661-2668