Ventilation rates in recently constructed US school classrooms

被引:61
作者
Batterman, S. [1 ]
Su, F. -C. [1 ]
Wald, A. [1 ]
Watkins, F. [1 ]
Godwin, C. [1 ]
Thun, G. [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
air change; carbon dioxide (CO2); high-performance buildings; ventilation; INDOOR AIR-QUALITY; CO2; CONCENTRATIONS; HEALTH; PERFORMANCE;
D O I
10.1111/ina.12384
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low ventilation rates (VRs) in schools have been associated with absenteeism, poorer academic performance, and teacher dissatisfaction. We measured VRs in 37 recently constructed or renovated and mechanically ventilated U.S. schools, including LEED and EnergyStar-certified buildings, using CO2 and the steady-state, build-up, decay, and transient mass balance methods. The transient mass balance method better matched conditions (specifically, changes in occupancy) and minimized biases seen in the other methods. During the school day, air change rates (ACRs) averaged 2.0 +/- 1.3 hour(-1), and only 22% of classrooms met recommended minimum ventilation rates. HVAC systems were shut off at the school day close, and ACRs dropped to 0.21 +/- 0.19 hour(-1). VRs did not differ by building type, although cost-cutting and comfort measures resulted in low VRs and potentially impaired IAQ. VRs were lower in schools that used unit ventilators or radiant heating, in smaller schools and in larger classrooms. The steady-state, build-up, and decay methods had significant limitations and biases, showing the need to confirm that these methods are appropriate. Findings highlight the need to increase VRs and to ensure that energy saving and comfort measures do not compromise ventilation and IAQ.
引用
收藏
页码:880 / 890
页数:11
相关论文
共 36 条
[1]  
American Society for Testing and Materials (ASTM), 2011, E741 ASTM
[2]  
[Anonymous], 2009, LEED 2009 SCH NEW CO
[3]  
ASHRAE, 2016, ASHRAE Standard 62.1 Ventilation for Acceptable Indoor Air Quality
[4]  
ASTM, 2012, STAND GUID US IND CA
[5]   Ventilation rates in schools and pupils' performance [J].
Bako-Biro, Zs. ;
Clements-Croome, D. J. ;
Kochhar, N. ;
Awbi, H. B. ;
Williams, M. J. .
BUILDING AND ENVIRONMENT, 2012, 48 :215-223
[6]  
BATTERMAN S, 2017, INT J ENV RES PUB HE, V14
[7]   A review of air exchange rate models for air pollution exposure assessments [J].
Breen, Michael S. ;
Schultz, Bradley D. ;
Sohn, Michael D. ;
Long, Thomas ;
Langstaff, John ;
Williams, Ronald ;
Isaacs, Kristin ;
Meng, Qing Yu ;
Stallings, Casson ;
Smith, Luther .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2014, 24 (06) :555-563
[8]   Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France [J].
Canha, N. ;
Mandin, C. ;
Ramalho, O. ;
Wyart, G. ;
Riberon, J. ;
Dassonville, C. ;
Hanninen, O. ;
Almeida, S. M. ;
Derbez, M. .
INDOOR AIR, 2016, 26 (03) :350-365
[9]   What does the scientific literature tell us about the ventilation-health relationship in public and residential buildings? [J].
Carrer, Paolo ;
Wargocki, Pawel ;
Fanetti, Annaclara ;
Bischof, Wolfgang ;
Fernandes, Eduardo De Oliveira ;
Hartmann, Thomas ;
Kephalopoulos, Stylianos ;
Palkonen, Susanna ;
Seppanen, Olli .
BUILDING AND ENVIRONMENT, 2015, 94 :273-286
[10]  
Chatzidiakou E., 2014, IS CO2 GOOD PROXY IN