A short bevel needle with a very thin tip improves vein puncture performance of peripheral intravenous catheters: An experimental study

被引:5
作者
Tanabe, Hidenori [1 ,2 ]
Kawasaki, Manami [2 ]
Ueda, Takehiko [3 ]
Yokota, Takayuki [3 ]
Zushi, Yasunobu [2 ]
Murayama, Ryoko [1 ,4 ]
Abe-Doi, Mari [1 ]
Sanada, Hiromi [4 ,5 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Adv Nursing Technol, Tokyo, Japan
[2] Terumo Co Ltd, Res & Dev Ctr, 1500 Inokuchi, Nakai, Kanagawa 2590151, Japan
[3] Terumo Co Ltd, Kofu Factory, Showa, Yamanashi, Japan
[4] Univ Tokyo, Global Nursing Res Ctr, Grad Sch Med, Tokyo, Japan
[5] Univ Tokyo, Grad Sch Med, Dept Gerontol Nursing Wound Care Management, Tokyo, Japan
关键词
Backcut; double-wall puncture; first-attempt success rate; lancet; needle; penetration force; peripheral intravenous catheter; short bevel; small vein; INTERNAL JUGULAR-VEIN; VENOUS ACCESS; COMPLICATIONS; PLACEMENT; INSERTION; DESIGN;
D O I
10.1177/1129729820920108
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Peripheral intravenous catheter placement is frequently unsuccessful at the first attempt. One suggested risk factor is a small vein size, because of the consequences of mechanical forces generated by the needle tip. We developed short bevel needles with a very thin tip and evaluated their puncture performance in two in vitro models. Methods: Peripheral intravenous catheters with a new needle ground using the lancet method (experimental catheter (L)) or backcut method (experimental catheter (B)) were compared with a conventional peripheral intravenous catheter (Surshield Surflo (R)) in a penetration force test and a tube puncture test. Penetration forces were measured when peripheral intravenous catheters penetrated a polyethylene sheet. The tube puncture test was used to evaluate whether the peripheral intravenous catheters could puncture a polyvinyl chloride tube at two positions, at the center and at 0.5 mm from the center of the tube. Results: Mean penetration forces at the needle tip produced by experimental catheters (L) (0.05 N) and (B) (0.04 N) were significantly lower than those produced by the conventional catheter (0.09 N) (p < 0.01). At the catheter tip, mean forces produced by experimental catheter (B) and the conventional catheter were 0.16 N and 0.26 N, respectively (p < 0.05). In the tube puncture test, the frequency at which the conventional catheter punctured the center-shifted site on the tube at an angle of 20 degrees and speed of 50 mm/min was low (40%). In contrast, experimental catheters (L) and (B) were 100% successful at puncturing both the center and center-shifted sites at 20 degrees. Conclusion: Puncture performance was comparable between the lancet-ground and backcut-ground needles except for penetration forces at the catheter tip. The experimental catheters produced lower penetration forces and induced puncture without target displacement at smaller angles compared with the conventional catheter. Therefore, optimization of the needle can prevent vein deformation and movement, which may increase the first-attempt success rate.
引用
收藏
页码:969 / 976
页数:8
相关论文
共 27 条
[1]   Needle insertion into soft tissue: A survey [J].
Abolhassani, Niki ;
Patel, Rajni ;
Moallem, Mehrdad .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (04) :413-431
[2]   Sensorless Motion Planning for Medical Needle Insertion in Deformable Tissues [J].
Alterovitz, Ron ;
Goldberg, Kenneth Y. ;
Pouliot, Jean ;
Hsu, I-Chow .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (02) :217-225
[3]  
Aponte Hector, 2007, AANA J, V75, P212
[4]   The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot [J].
Balter, Max L. ;
Chen, Alvin I. ;
Maguire, Timothy J. ;
Yarmush, Martin L. .
IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (04) :1044-1053
[5]   Peripheral intravenous access in the operating room: Characteristics and predictors of difficulty [J].
Bensghir, M. ;
Chkoura, K. ;
Mounir, K. ;
Drissi, M. ;
Elwali, A. ;
Ahtil, R. ;
Meziane, M. ;
Alaoui, H. ;
Elmoqadem, A. ;
Lahlou, J. ;
Hatim, A. ;
Azendour, H. ;
Kamili, N. Drissi .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2012, 31 (7-8) :600-604
[6]   Emergency nurses' utilization of ultrasound guidance for placement of peripheral intravenous lines in difficult-access patients [J].
Brannam, L ;
Blaivas, M ;
Lyon, M ;
Flake, M .
ACADEMIC EMERGENCY MEDICINE, 2004, 11 (12) :1361-1363
[7]  
Chen AI, 2015, IEEE INT C INT ROBOT, P2633, DOI 10.1109/IROS.2015.7353736
[8]   A hand-held robotic device for peripheral intravenous catheterization [J].
Cheng, Zhuoqi ;
Davies, Brian L. ;
Caldwell, Darwin G. ;
Barresi, Giacinto ;
Xu, Qinqi ;
Mattos, Leonardo S. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (12) :1165-1177
[9]   Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access [J].
Costantino, TG ;
Parikh, AK ;
Satz, WA ;
Fojtik, JP .
ANNALS OF EMERGENCY MEDICINE, 2005, 46 (05) :456-461
[10]   Intravenous Therapy A Review of Complications and Economic Considerations of Peripheral Access [J].
Dychter, Samuel S. ;
Gold, David A. ;
Carson, Deborah ;
Haller, Michael .
JOURNAL OF INFUSION NURSING, 2012, 35 (02) :84-91