Derivatization and fragmentation pattern analysis of natural and synthetic steroids, as their trimethylsilyl (oxime) ether derivatives by gas chromatography mass spectrometry: Analysis of dissolved steroids in wastewater samples

被引:25
|
作者
Andrasi, N. [1 ]
Helenkar, A. [1 ]
Zaray, Gy [1 ]
Vasanits, A. [1 ]
Molnar-Perl, I. [1 ]
机构
[1] Eotvos Lorand Univ, Dept Analyt Chem, Inst Chem, H-1518 Budapest 112, Hungary
关键词
Steroids; Gas chromatography-mass spectrometry; Oximation; Trimethylsilylation; Fragmentation patterns; Aquatic environmental pollutant; SOLID-PHASE EXTRACTION; ENDOCRINE DISRUPTING CHEMICALS; ANABOLIC-STEROIDS; HUMAN SERUM; ACIDIC PHARMACEUTICALS; ESTROGENS ESTRONE; FECAL STEROLS; KIDNEY FAT; QUANTIFICATION; HORMONES;
D O I
10.1016/j.chroma.2011.01.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the extension of our multiresidue analysis (MA) procedure with 18 natural and synthetic steroids; permitting the identification and quantification, in total of 81 pollutants from one solution, by a single injection, as their trimethylsilyl (TMS)-oxime ether/ester derivatives, by gas chromatography-mass spectrometry (GC-MS), within 31 min. As a novelty to the field, basic researches, such as fragmentation pattern analysis and derivatization optimization studies were performed for androsterone, transdehydroandrosterone, transandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxy-progesterone-acetate, stigmasterol and beta-sitosterol. Results confirmed that (i) the TMS oxime-ether derivatives of the keto steroids provide from 1.40 times (gestodene) up to 4.25 times (norethisterone) higher responses compared to their TMS-ether ones, and (ii) the distribution of syn/anti oximes is characteristic to the ketosteroid species examined. Based on our optimized mass fragmentation, solid phase extraction (SPE) and derivatization studies separations have been performed in the total ion current (TIC) mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Responses, obtained with derivatized standards proved to be linear (hydroxysteroids), or have been calculated from calibration curves (ketosteroids) in the range of 1.88-750 ng/L levels. Limit of quantitation (LOQ) values varied between 1.88 ng/L and 37.5 ng/L concentrations. The most important practical messages of this work are the high androsterone (0.744-4.28 mu g/L), transandrosterone (0.138-4.00 mu g/L). coprostanol (2.11-302 mu g/L), cholesterol (0.308-41 mu g/L), stigmasterol (1.21-8.40 mu g/L)and beta-sitosterol (1.12-11.0 mu g/L) contents of influent wastewaters. beta-Estradiol (100 ng/L) and estriol (54 ng/L) were found in one influent sample, only. Reproducibilities, characterized with the relative standard deviation percentages (RSD%) of measurements, varied between 1.73 RSD% (beta-estradiol) and 5.4 RSD% (stigmasterol), with an average of 4.82 RSD%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1878 / 1890
页数:13
相关论文
共 48 条
  • [1] The role of the acquisition methods in the analysis of natural and synthetic steroids and cholic acids by gas chromatography-mass spectrometry
    Andrasi, N.
    Helenkar, A.
    Vasanits-Zsigrai, A.
    Zaray, Gy.
    Molnar-Perl, I.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (45) : 8264 - 8272
  • [2] Gas chromatography-mass spectrometry of the trimethylsilyl (oxime) ether/ester derivatives of cholic acids: Their presence in the aquatic environment
    Sebok, A.
    Sezerc, K.
    Vasanits-Zsigrai, A.
    Helenkar, A.
    Zaray, Gy.
    Molnar-Perl, I.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1211 (1-2) : 104 - 112
  • [3] Enhanced Analysis of Steroids by Gas Chromatography/Mass Spectrometry using Microwave-Accelerated Derivatization
    Bowden, John A.
    Colosi, Dominic M.
    Stutts, Whitney L.
    Mora-Montero, Diana C.
    Garrett, Timothy J.
    Yost, Richard A.
    ANALYTICAL CHEMISTRY, 2009, 81 (16) : 6725 - 6734
  • [4] Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine
    Cha, Eunju
    Jeong, Eun Sook
    Cha, Sangwon
    Lee, Jaeick
    ANALYTICA CHIMICA ACTA, 2017, 964 : 123 - 133
  • [5] Determination of steroids in the dissolved and in the suspended phases of wastewater and Danube River samples by gas chromatography, tandem mass spectrometry
    Andrasi, Nora
    Molnar, Borbala
    Dobos, Bernadett
    Vasanits-Zsigrai, Aniko
    Zaray, Gyula
    Molnar-Perl, Ibolya
    TALANTA, 2013, 115 : 367 - 373
  • [6] Multiresidue analysis of pollutants as their trimethylsilyl derivatives, by gas chromatography-mass spectrometry
    Sebok, A.
    Vasanits-Zsigrai, A.
    Helenkar, A.
    Zaray, Gy.
    Molnar-Perl, I.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) : 2288 - 2301
  • [7] Liquid chromatography tandem mass spectrometry applied to the analysis of natural and synthetic steroids in environmental waters
    Laganà, A
    Fago, G
    Marino, A
    Santarelli, D
    ANALYTICAL LETTERS, 2001, 34 (06) : 913 - 926
  • [8] Gas chromatography electrospray ionization mass spectrometry analysis of trimethylsilyl derivatives
    Hsu, Ren-Yu
    Liao, Jhan-Hong
    Tien, Hsin-Wen
    Her, Guor-Rong
    JOURNAL OF MASS SPECTROMETRY, 2016, 51 (10): : 883 - 888
  • [9] Characteristic fragmentation patterns of the trimethylsilyl and trimethylsilyl-oxime derivatives of various saccharides as obtained by gas chromatography coupled to ion-trap mass spectrometry
    Fuzfai, Zs.
    Boldizsar, I.
    Molnar-Perl, I.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) : 183 - 189
  • [10] Characteristic fragmentation patterns of trimethylsilyl and trimethylsilyl-oxime derivatives of plant disaccharides as obtained by gas chromatography coupled to ion-trap mass spectrometry
    Boldizsar, I.
    Fuezfai, Zs.
    Molnar-Perl, I.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (43) : 7864 - 7868