Modelling and calibration of parallel mechanisms using linear optical sensors and a coordinate measuring machine

被引:17
作者
Majarena, A. C. [1 ]
Santolaria, J. [1 ]
Samper, D. [1 ]
Aguilar, J. J. [1 ]
机构
[1] Univ Zaragoza, Dept Design & Mfg Engn, Zaragoza 50018, Spain
关键词
modelling; external sensor calibration; parallel mechanism; linear optical sensor; coordinate measuring machine; KINEMATIC CALIBRATION; POSE MEASUREMENT; MANIPULATOR; ROBOT; MOTION; RANGE;
D O I
10.1088/0957-0233/22/10/105101
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a new procedure for the modelling and calibration of a parallel mechanism by using linear optical sensors and a coordinate measuring machine. Three standard spheres, fixed to the moving platform, were measured by means of a coordinate measuring machine. Additionally, a control algorithm was developed to store sensor readings in each analysed position. These readings and the kinematic model allow us to obtain the calculated sphere coordinates. The use of high-accuracy linear optical sensors allows us to correct actuator backlash, thereby increasing the mechanism accuracy. The developed method defines an objective function that compares the measured and calculated coordinates of the three-sphere centres in order to obtain the identified model parameters that minimize this difference. This procedure combines both inverse and forward kinematics, and solves the nonlinear system loop of the kinematic model inside a second loop that optimizes the geometric parameters of the model. Numerical optimization techniques based on Levenberg-Marquardt algorithm are used to solve both optimization loops. Results show that the platform position and orientation errors are improved by more than one order of magnitude.
引用
收藏
页数:12
相关论文
共 44 条
[1]   Experimental kinematic calibration of parallel manipulators using a relative position error measurement system [J].
Abtahi, Mansour ;
Pendar, Hodjat ;
Alasty, Aria ;
Vossoughi, Gholamreza .
ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2010, 26 (06) :799-804
[2]  
Agheli M.M., 2009, International Journal of Mechanical Systems Science and Engineering, V1, P149
[3]   Kinematic calibration and pose measurement of a medical parallel manipulator by optical position sensors [J].
Bai, SP ;
Teo, MY .
JOURNAL OF ROBOTIC SYSTEMS, 2003, 20 (04) :201-209
[4]   A novel six degrees-of-freedom parallel robot for MEMS fabrication [J].
Bamberger, Hagay ;
Shoham, Moshe .
IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (02) :189-195
[5]  
Besnard S, 1999, ICRA '99: IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, PROCEEDINGS, P1758, DOI 10.1109/ROBOT.1999.770363
[6]  
Bonev IA, 1999, P IEEE ASME INT C AD, P526
[7]   Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm [J].
Chiang, Mao-Hsiung ;
Lin, Hao-Ting ;
Hou, Chien-Lun .
SENSORS, 2011, 11 (02) :2257-2281
[8]  
Cong DC, 2006, WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, P8514
[9]   Spatial resolution-based kinematic design of a parallel positioning platform [J].
Cristina Majarena, Ana ;
Santolaria, Jorge ;
Samper, David ;
Aguilar Martin, Juan Jose .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2011, 53 (9-12) :1149-1165
[10]   Interval methods for certification of the kinematic calibration of parallel robots [J].
Daney, D ;
Papegay, Y ;
Neumaier, A .
2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, :1913-1918