Electrorotation chip consisting of three-dimensional interdigitated array electrodes

被引:17
作者
Ino, Kosuke [1 ]
Ishida, Atsuko [1 ]
Inoue, Kumi Y. [1 ]
Suzuki, Masato [1 ]
Koide, Masahiro [1 ,2 ,3 ]
Yasukawa, Tomoyuki [4 ]
Shikua, Hitoshi [1 ]
Matsue, Tomokazu [1 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Aoba Ku, Sendai, Miyagi 9808579, Japan
[2] Natl Inst Environm Studies, Div Environm Chem, Tsukuba, Ibaraki 3058506, Japan
[3] Natl Inst Environm Studies, Res Ctr Environm Risk, Tsukuba, Ibaraki 3058506, Japan
[4] Univ Hyogo, Grad Sch Mat Sci, Ako, Hyogo 6781297, Japan
基金
日本学术振兴会;
关键词
Electrorotation; IDA electrode; Lab-on-a-chip device; Particle manipulation; MEMS; POSITIVE DIELECTROPHORESIS; COLLOIDAL PARTICLES; YEAST-CELLS; MICROELECTRODES;
D O I
10.1016/j.snb.2010.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an electrorotation (ER) chip that has a sandwich structure in which interdigitated array (IDA) electrodes are arranged face-to-face. These IDA electrodes on the top and bottom of the chip were orthogonally arranged to form over 2000 square regions having rotating electric fields between the IDA electrodes. Since rotating electric fields can be generated by arranging the electrical connections to produce a pi/2 phase difference between adjacent electrodes, a large number of measurement areas for ER were incorporated within a single ER chip. The ER properties of glass microrods at the individual measurement areas were investigated using this ER chip. The present ER chip was found to be a useful tool for performing high-throughput assays to analyze the dielectric properties of microparticles. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 473
页数:6
相关论文
共 20 条
[1]   Electrorotation studies of baby hamster kidney fibroblasts infected with herpes simplex virus type 1 [J].
Archer, S ;
Morgan, H ;
Rixon, FJ .
BIOPHYSICAL JOURNAL, 1999, 76 (05) :2833-2842
[2]  
ARNOLD WM, 1982, Z NATURFORSCH C, V37, P908
[3]   Alterations of the Plasma Membrane Caused by Murine Polyomavirus Proliferation: An Electrorotation Study [J].
Berardi, Valerio ;
Aiello, Cecilia ;
Bonincontro, Adalberto ;
Risuleo, Gianfranco .
JOURNAL OF MEMBRANE BIOLOGY, 2009, 229 (01) :19-25
[4]   A combined dielectrophoresis, traveling wave dielectrophoresis and electrorotation microchip for the manipulation and characterization of human malignant cells [J].
Cen, EG ;
Dalton, C ;
Li, YL ;
Adamia, S ;
Pilarski, LM ;
Kaler, KVIS .
JOURNAL OF MICROBIOLOGICAL METHODS, 2004, 58 (03) :387-401
[5]   A continuous high-throughput bioparticle sorter based on 3D traveling-wave dielectrophoresis [J].
Cheng, I-Fang ;
Froude, Victoria E. ;
Zhu, Yingxi ;
Chang, Hsueh-Chia ;
Chang, Hsien-Chang .
LAB ON A CHIP, 2009, 9 (22) :3193-3201
[6]   Membrane dielectric responses of bufalin-induced apoptosis in HL-60 cells detected by an electrorotation chip [J].
Huang, Chengjun ;
Chen, Ailiang ;
Guo, Min ;
Yu, Jun .
BIOTECHNOLOGY LETTERS, 2007, 29 (09) :1307-1313
[7]   ELECTRODE DESIGN FOR NEGATIVE DIELECTROPHORESIS [J].
HUANG, Y ;
PETHIG, R .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) :1142-1146
[8]   Mapping the electrorotational torque in planar microelectrodes [J].
Hughes, MP ;
Archer, S ;
Morgan, H .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (13) :1548-1552
[9]   AC electrokinetics: applications for nanotechnology [J].
Hughes, MP .
NANOTECHNOLOGY, 2000, 11 (02) :124-132
[10]   Detection of hormone active chemicals using genetically engineered yeast cells and microfluidic devices with interdigitated array electrodes [J].
Ino, Kosuke ;
Kitagawa, Yusuke ;
Watanabe, Tsuyoshi ;
Shiku, Hitoshi ;
Koide, Masahiro ;
Itayama, Tomoaki ;
Yasukawa, Tomoyuki ;
Matsue, Tomokazu .
ELECTROPHORESIS, 2009, 30 (19) :3406-3412