High-Throughput Sequential Injection Method for Simultaneous Determination of Plutonium and Neptunium in Environmental Solids Using Macroporous Anion-Exchange Chromatography, Followed by Inductively Coupled Plasma Mass Spectrometric Detection

被引:40
作者
Qiao, Jixin [1 ]
Hou, Xiaolin [1 ]
Roos, Per [1 ]
Miro, Manuel [2 ]
机构
[1] Tech Univ Denmark, Div Radiat Res, Riso Natl Lab Sustainable Energy, DK-4000 Roskilde, Denmark
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Illes Balears, Spain
关键词
PU-ISOTOPES; ION CHROMATOGRAPHY; SAMPLES; NP-237; SEPARATION; ACTINIDES; FALLOUT; TRACER;
D O I
10.1021/ac102567b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports an automated analytical method for rapid and simultaneous determination of plutonium and neptunium in soil, sediment, and seaweed, with detection via inductively coupled plasma mass spectrometry (ICP-MS). A chromatographic column packed with a macroporous anion exchanger (AG MP-1 M) was incorporated in a sequential injection (SI) system for the efficient retrieval of plutonium, along with neptunium, from matrix elements and potential interfering nuclides. The sorption and elution behavior of plutonium and neptunium onto AG MP-1 M resin was compared with a commonly utilized AG 1-gel-type anion exchanger. Experimental results reveal that the pore structure of the anion exchanger plays a pivotal role in ensuring similar separation behavior of plutonium and neptunium along the separation protocol. It is proven that plutonium-242 ((242)Pu) performs well as a tracer for monitoring the chemical yield of neptunium when using AG MP-1 M resin, whereby the difficulties in obtaining a reliable and practicable isotopic neptunium tracer are overcome. An important asset of the SI setup is the feasibility of processing up to 100 g of solid substrates using a small-sized (ca. 2 mL) column with chemical yields of neptunium and plutonium being 79%. Analytical results of three certified/standard reference materials and two solid samples from intercomparison exercises are in good agreement with the reference values at the 0.05 significance level. The overall on-column separation can be completed within 3.5 h for 10 g of soil samples. Most importantly, the anion-exchange mini-column suffices to be reused up to 10-fold with satisfactory chemical yields (>70%), as demanded in environmental monitoring and emergency scenarios, making the proposed automated assembly well-suited for unattended and high-throughput analysis.
引用
收藏
页码:374 / 381
页数:8
相关论文
共 28 条
[1]  
[Anonymous], 1993, Statistics for Analytical Chemistry
[2]   Np-237/Pu-239 atom ratios in integrated global fallout: a reassessment of the production of Np-237 [J].
Beasley, TM ;
Kelley, JM ;
Maiti, TC ;
Bond, LA .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1998, 38 (02) :133-146
[3]  
BURNEY GA, 1974, 3060 NASNS US AT EN
[4]   Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry [J].
Chamizo, E. ;
Jimenez-Ramos, M. C. ;
Wacker, L. ;
Vioque, I. ;
Calleja, A. ;
Garcia-Leon, M. ;
Garcia-Tenorio, R. .
ANALYTICA CHIMICA ACTA, 2008, 606 (02) :239-245
[5]   242Pu as tracer for simultaneous determination of 237Np and 239,240Pu in environmental samples [J].
Chen, QJ ;
Dahlgaard, H ;
Nielsen, SP ;
Aarkrog, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (03) :451-458
[6]  
Chen QJ, 2001, J RADIOANAL NUCL CH, V249, P527
[7]   SEPARATION AND PRECONCENTRATION OF ACTINIDES BY EXTRACTION CHROMATOGRAPHY USING A SUPPORTED LIQUID ANION-EXCHANGER - APPLICATION TO THE CHARACTERIZATION OF HIGH-LEVEL NUCLEAR WASTE SOLUTIONS [J].
HORWITZ, EP ;
DIETZ, ML ;
CHIARIZIA, R ;
DIAMOND, H ;
MAXWELL, SL ;
NELSON, MR .
ANALYTICA CHIMICA ACTA, 1995, 310 (01) :63-78
[8]   Global distribution of Pu isotopes and 237Np [J].
Kelley, JM ;
Bond, LA ;
Beasley, TM .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 238 :483-500
[9]   Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution [J].
Kenna, TC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (11) :1471-1479
[10]   Simultaneous analysis of 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system [J].
Kim, CS ;
Kim, CK ;
Lee, KJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (06) :743-750