Box-Behnken response surface modeling assisted enantiomeric resolution of some racemic β-blockers using HPTLC and β-cyclodextrin as chiral mobile phase additive: Application to check the enantiomeric purity of betaxolol

被引:5
作者
El-Kimary, Eman I. [1 ]
Ragab, Marwa A. A. [1 ]
机构
[1] Alexandria Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Alexandria 21521, Egypt
关键词
Box-Behnken design; enantiomeric purity; enantiomeric resolution; mobile phase additive; validated HPTLC; beta-blockers; beta-cyclodextrin; EXPERIMENTAL-DESIGN; TLC RESOLUTION; OPTIMIZATION; SEPARATION; ASSAY;
D O I
10.1002/chir.23012
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Stereospecific separation method of (+/-) betaxolol, (+/-) carvedilol, and (+/-) sotalol using High Performance Thin Layer Chromatography (HPTLC) and -cyclodextrin as chiral selector has been developed and validated. The Box-Behnken surface response design was selected for optimizing the operating variables based on 15 trials design. The optimized method involves separation on Fluka HPTLC silica gel plates 60F(254) (20x10cm) using acetonitrile-methanol-acetic acid-water (3.4:3.6:0.18:1v/v) as a mobile phase containing 0.57mM -cyclodextrin. Densitometric measurements were made at 220nm for betaxolol and sotalol or at 245nm for carvedilol. Maximum separation of the enantiomers of the three drugs was obtained by optimizing concentration of chiral selector, the mobile phase composition including acetonitrile amount in the organic part of the mobile phase and the volume of acetic acid added. The proposed method enables estimation of (-) and (+) enantiomers of betaxolol in drug substance and in various pharmaceuticals. The detection limit of betaxolol was 0.15 and 0.13g band(-1) for (-) and (+) enantiomers, respectively. The detection limits were found to be 0.2 and 0.3g band(-1) for carvedilol and sotalol, respectively, as racemate. In addition, the proposed method was applied in checking the enantiomeric purity of (-) BET in the presence of (+) BET at 1% level where the inactive (+) enantiomer was quantified with good accuracy and precision at 1% level in the active (-) enantiomer.
引用
收藏
页码:1195 / 1205
页数:11
相关论文
共 22 条
[1]  
[Anonymous], 2005, Validation of analytical procedures: Text and methodology Q2 (R1)
[2]   Direct enantiomeric resolution of (±)-atenolol, (±)-metoprolol, and (±)-propranolol by impregnated TLC using L-aspartic acid as chiral selector [J].
Bhushan, R ;
Arora, M .
BIOMEDICAL CHROMATOGRAPHY, 2003, 17 (04) :226-230
[3]   Enantioseparation of some β-adrenergic blocking agents using impregnated thin-layer chromatography [J].
Bhushan, R ;
Thiongo, GT .
JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2) :330-334
[4]   Direct TLC resolution of atenolol and propranolol into their enantiomers using three different chiral selectors as impregnating reagents [J].
Bhushan, Ravi ;
Tanwar, Shivani .
BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (09) :1028-1034
[5]   Direct resolution of six beta blockers into their enantiomers on silica plates impregnated with L-Asp and L-Glu [J].
Bhushan, Ravi ;
Agarwal, Charu .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2008, 21 (02) :129-134
[6]   Ligand-exchange TLC resolution of some racemic β-adrenergic blocking agents [J].
Bhushan, Ravi ;
Gupta, Deepak .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2006, 19 (109) :241-245
[7]   Experimental design and multiple response optimization. Using the desirability function in analytical methods development [J].
Candioti, Luciana Vera ;
De Zan, Maria M. ;
Camara, Maria S. ;
Goicoechea, Hector C. .
TALANTA, 2014, 124 :123-138
[8]   Novel Validated HPTLC Method for the Analysis of Two Binary Mixtures Containing Tamsulosin Hydrochloride with Antimuscarinic Agents [J].
El-Kimary, Eman I. ;
Khamis, Essam F. ;
Belal, Saeid F. ;
Moneim, Mona M. Abdel .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2018, 56 (01) :81-91
[9]   HPTLC and Spectrophotometric Estimation of Febuxostat and Diclofenac Potassium in Their Combined Tablets [J].
El-Yazbi, Fawzi A. ;
Amin, Omayma A. ;
El-Kimary, Eman I. ;
Khamis, Essam F. ;
Younis, Sameh E. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (07) :1146-1152
[10]   Box-Behnken design: An alternative for the optimization of analytical methods [J].
Ferreira, S. L. C. ;
Bruns, R. E. ;
Ferreira, H. S. ;
Matos, G. D. ;
David, J. M. ;
Brandao, G. C. ;
da Silva, E. G. P. ;
Portugal, L. A. ;
dos Reis, P. S. ;
Souza, A. S. ;
dos Santos, W. N. L. .
ANALYTICA CHIMICA ACTA, 2007, 597 (02) :179-186