Improved imaging of hepatic metastases with delayed pulse inversion harmonic imaging using a contrast agent SHU 508A: Preliminary study

被引:25
作者
Kim, TK
Choi, BI
Hong, HS
Choi, BY
Han, JK
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Clin Res Inst, Seoul, South Korea
关键词
ultrasound; liver neoplasms; metastases; pulse inversion harmonic imaging; ultrasound contrast agents;
D O I
10.1016/S0301-5629(00)00268-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To investigate the feasibility of delayed pulse-inversion harmonic imaging (PIHI) with the SH U 508A to improve imaging of hepatic metastases, we evaluated 20 patients with known hepatic metastases. Conventional ultrasound (US) was performed before administration, and PIHI was performed 5 min after a bolus injection of 4 G of microbubble contrast agent (300 mg/mL of SH U 508A). Intense, homogeneous enhancement in the liver parenchyma was seen in all patients on delayed PTHI. In 10 patients (50%), 1 or more focal liver lesions that were not seen on unenhanced imaging were detected on delayed PIHI. When comparing 55 lesions that were seen on both techniques, delayed PIHI was superior to unenhanced imaging in terms of lesion conspicuity and lesion-to-liver contrast (p < 0.001, respectively). Delayed PIHI with SH U 508A can improve conspicuity of hepatic metastases and reveal focal liver lesions that are not detected on unenhanced imaging. (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1439 / 1444
页数:6
相关论文
共 14 条
[1]  
BAUER A, 1997, ADV ECHO IMAGING USI, P669
[2]   Stimulated acoustic emission in liver parenchyma with Levovist [J].
Blomley, M ;
Albrecht, T ;
Cosgrove, D ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, R .
LANCET, 1998, 351 (9102) :568-568
[3]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[4]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[5]  
Burns PN, 1998, RADIOLOGY, V209P, P189
[6]  
BURNS PN, 1996, RADIOLOGY, V201, P159
[7]  
BURNS PN, 1996, RADIOLOGY, V201, P158
[8]   Analysis of flash echo from contrast agent for designing optimal ultrasound diagnostic systems [J].
Kamiyama, N ;
Moriyasu, F ;
Mine, Y ;
Goto, Y .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (03) :411-420
[9]  
KIM TK, 2000, IN PRESS RADIOLOGY, V216
[10]   Gray-scale second harmonic imaging of the liver with galactose-based microbubbles [J].
Kono, Y ;
Moriyasu, F ;
Mine, Y ;
Nada, T ;
Kamiyama, N ;
Suginoshita, Y ;
Matsumura, T ;
Kobayashi, K ;
Chiba, T .