Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam

被引:18
作者
Min, C. H.
Kim, J. W.
Youn, M. Y.
Kim, C. H. [1 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Natl Canc Ctr, Gyeonggi 411769, South Korea
[3] Seoul Natl Univ, Natl Ctr Inter Univ Res Facil, Seoul 151742, South Korea
基金
欧洲研究理事会;
关键词
proton therapy; dosimetry; proton range; prompt gammas; Monte Carlo;
D O I
10.1016/j.nima.2007.05.235
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(T1) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was tested with a 38 MeV proton beam at the Korea cancer center hospital (KCCH). The experiment was also simulated, using a Monte Carlo particle transport simulation code, MCNPX. Our result is very encouraging, showing that there is a clear correlation between the distribution of the prompt gammas and the location of the distal dose edge for the 38 MeV proton beam. According to our result, we believe that the location of the distal dose edge can be determined within 1-2 mm from the distribution of the prompt gammas. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:562 / 565
页数:4
相关论文
共 10 条
[1]  
[Anonymous], 2003, 39 MEET PART
[2]   Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization [J].
Carlsson, AK ;
Andreo, P ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) :1033-1053
[3]  
CHADWICK MB, 1999, LAUR991222 LOS ALM N
[4]   A proton dose calculation algorithm for conformal therapy simulations based on Moliere's theory of lateral deflections [J].
Deasy, JO .
MEDICAL PHYSICS, 1998, 25 (04) :476-483
[5]  
JOHN S, 2004, LAUR040569 LOS AL NA
[6]  
Kanematsu N., 1998, JPN J MED PHYS, V18, P88
[7]   A filtering approach based on Gaussian-powerlaw convolutions for local PET verification of proton radiotherapy [J].
Parodi, Katia ;
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08) :1991-2009
[8]   DIFFERENTIAL-PENCIL-BEAM DOSE CALCULATIONS FOR CHARGED-PARTICLES [J].
PETTI, PL .
MEDICAL PHYSICS, 1992, 19 (01) :137-149
[9]   Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation [J].
Schaffner, B ;
Pedroni, E ;
Lomax, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :27-41
[10]  
SEO K, 2005, P 30 C SPRING KOR SO, P100