Comparative scoring of micronucleated reticulocytes in rat peripheral blood by flow cytometry and microscopy

被引:74
|
作者
Torous, DK [1 ]
Hall, NE [1 ]
Murante, FG [1 ]
Gleason, SE [1 ]
Tometsko, CR [1 ]
Dertinger, SD [1 ]
机构
[1] Litron Labs, Rochester, NY 14620 USA
关键词
micronuclei; genotoxicity; flow cytometry; rats; CD71; antigen;
D O I
10.1093/toxsci/kfg143
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
A flow cytometric technique for scoring the incidence of micronucleated reticulocytes in rat peripheral blood was compared to a standard microscopy-based procedure. For these studies, groups of five male Sprague-Dawley rats were treated with vehicle or a broad range of chemical genotoxicants: 6-thioguanine, N-methyl-N'-nitro-N-nitrosoguanidine, vincristine, methylaziridine, acetaldehyde, methyl methanesulfonate, benzene, monocrotaline, and azathioprine. Animals were treated once a day for up to 2 days, and peripheral blood was collected between 24 and 48 In after the final administration. These samples were processed for flow cytometric scoring and microscopy-based analysis using supravital acridine orange staining, and the percentage of reticulocytes and micronucleated reticulocytes was determined for each sample. The resulting data demonstrate good agreement between these scoring methodologies, although careful execution of the flow cytometric method was found to enhance the micronucleus assay by reducing both scoring time and scoring error. These data add further support to the premise that the peripheral blood compartment of rats can be used effectively to detect genotoxicant-induced micronuclei.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [21] Flow cytometric assessment of micronucleated rat blood cells in toxicity studies
    Roman, D
    Elhajouji, A
    Pralet, D
    Kovalchuk, Z
    Suter, W
    Germann, PG
    CYTOMETRY, 2002, : 123 - 123
  • [22] A FLOW CYTOMETRIC METHOD FOR THE ENUMERATION OF RETICULOCYTES IN PERIPHERAL-BLOOD
    DARDANO, JR
    JOHNSON, PC
    LEACH, C
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1986, 57 (05): : 513 - 513
  • [23] USE OF RHODAMINE-123 FLOW CYTOMETRIC QUANTIFICATION OF RAT AND HUMAN PERIPHERAL-BLOOD RETICULOCYTES
    PRUDHOMME, J
    COTTON, S
    DOUMEYROU, F
    GRUNWALD, D
    FRELAT, G
    BIOLOGY OF THE CELL, 1986, 58 (03) : A29 - A29
  • [24] Malaria-infected erythrocytes serve as biological standards to ensure reliable and consistent scoring of micronucleated erythrocytes by flow cytometry
    Dertinger, SD
    Torous, DK
    Hall, NE
    Tometsko, CR
    Gasiewicz, TA
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2000, 464 (02) : 195 - 200
  • [25] USE OF FLOW CYTOMETRY IN INVESTIGATION OF PERIPHERAL BLOOD LYMPHOCYTOSIS
    Ogilvie, C.
    Doig, A.
    Mckay, P.
    Leach, M.
    ANNALS OF ONCOLOGY, 2011, 22 : 242 - 242
  • [26] Use Of Flow Cytometry To Identify Myelodysplasia In Peripheral Blood
    Kern, Wolfgang
    Schabath, Richard
    Alpermann, Tamara
    Haferlach, Claudia
    Schnittger, Susanne
    Haferlach, Torsten
    BLOOD, 2013, 122 (21)
  • [27] Detection of myeloma cells in the peripheral blood by flow cytometry
    Witzig, TE
    Kimlinger, TK
    Ahmann, GJ
    Katzmann, JA
    Greipp, PR
    CYTOMETRY, 1996, 26 (02): : 113 - 120
  • [28] IDENTIFICATION OF DYSPLASIA IN PERIPHERAL BLOOD USING FLOW CYTOMETRY
    Schabath, R.
    Alperman, T.
    Haferlach, C.
    Schnittger, S.
    Haferlach, T.
    Kern, W.
    HAEMATOLOGICA, 2014, 99 : 92 - 92
  • [29] FLOW-CYTOMETRIC ENUMERATION OF MICRONUCLEATED POLYCHROMATIC ERYTHROCYTES IN MOUSE PERIPHERAL-BLOOD
    GRAWE, J
    ZETTERBERG, G
    AMNEUS, H
    CYTOMETRY, 1992, 13 (07): : 750 - 758
  • [30] Early detection of cytogenetic damage from radiation or chemical agents by flow-cytometric analysis of micronucleated CD71-positive reticulocytes in human peripheral blood
    Chen, Y
    Dertinger, SD
    Pandya, K
    Torous, DK
    Brewer, KJ
    Smudzin, T
    Miller, RK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S366 - S366