Application of artificial neural network for predicting performance of solid desiccant cooling systems - A review

被引:75
作者
Jani, D. B. [1 ]
Mishra, Manish [2 ]
Sahoo, P. K. [2 ]
机构
[1] GTU, Dept Gujarat Technol Univ, Ahmadabad, Gujarat, India
[2] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttar Pradesh, India
关键词
ANN; Desiccant cooling; Dehumidifier; COP; Regeneration; AIR-CONDITIONING SYSTEM; SOLAR-ASSISTED DESICCANT; VAPOR-COMPRESSION; REFRIGERATION SYSTEM; NUMERICAL-ANALYSIS; ENERGY-SYSTEMS; HEAT; TEMPERATURE; HOT; DEHUMIDIFIER;
D O I
10.1016/j.rser.2017.05.169
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In present study, an attempt has been made to review the applications of artificial neural network (ANN) for predicting the performance of solid desiccant cooling systems. Different types of neural networks are applied to model the solid desiccant cooling systems. With use of experimental data, an ANN model was developed which is based on different algorithms. Available experimental data were divided into two categories for training and testing of the ANN model. Later on, trained ANN model was tested for predicting the performance of system based on various input and output parameters such as air stream flow rates, temperatures and humidity ratios, pressure drop, dehumidifier effectiveness, cooling capacity, regeneration temperature, power input, coefficient of performance etc. So, present review proposes the use of ANN based model to simulate the relationship between inlet and outlet parameters of the system. The ANN predictions for these parameters usually agreed with the experimental values with higher correlation co-efficient. The previous studies show that ANNs can be used with a higher precision in guessing the performance of solid desiccant cooling systems. This review is useful for making opportunities to further research of ANNs and its feasibility which is becoming common in the coming days.
引用
收藏
页码:352 / 366
页数:15
相关论文
共 118 条
[1]   Numerical modeling of ventilated wall cavities with spray evaporative cooling system [J].
Alaidroos, Alaa ;
Krarti, Moncef .
ENERGY AND BUILDINGS, 2016, 130 :350-365
[2]   Experimental investigation to optimise a desiccant HVAC system coupled to a small size cogenerator [J].
Angrisani, Giovanni ;
Minichiello, Francesco ;
Roselli, Carlo ;
Sasso, Maurizio .
APPLIED THERMAL ENGINEERING, 2011, 31 (04) :506-512
[3]  
[Anonymous], 1982, THESIS
[4]  
[Anonymous], APPL THERM ENG
[5]  
[Anonymous], P 11 INT C FLUID DYN
[6]  
[Anonymous], AM J ENERGY ENG
[7]  
[Anonymous], 2015, INT J HYBRID INF TEC, DOI DOI 10.14257/IJHIT.2015.8.9.23
[8]  
[Anonymous], 1988, ASHRAE T
[9]  
[Anonymous], SCI TECHNOL BUILT EN
[10]  
[Anonymous], 2016, SUSTAINABILITY-BASEL