Design and Shimming Method of Low Length-to-Interdiameter Ratio Halbach Magnet

被引:4
作者
Wang, Junnan [1 ]
Jiang, Xiaowen [1 ]
Hu, Zhu [1 ]
Chen, Yi [1 ]
Wu, Yuchen [1 ]
Bi, Kedong [1 ]
Ni, Zhonghua [1 ]
Yi, Hong [1 ]
Lu, Rongsheng [2 ,3 ]
机构
[1] Southeast Univ, Jiangsu Key Lab Design & Manufacture Micronano Bi, Nanjing 210096, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Design & Manufacture Micronano Bi, Sch Mech Engn, Nanjing 210096, Peoples R China
[3] Southeast Univ, Natl Key Lab Bioelect, Sch Mech Engn, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Halbach array; magnetic resonance imaging; passive shimming method; permanent magnet; RESOLUTION NMR-SPECTROSCOPY; PERMANENT-MAGNET; FIELD; OPTIMIZATION;
D O I
10.1109/TIM.2022.3199233
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The conventional Halbach permanent magnet usually has a high length-to-interdiameter ratio (LDIR) to gain a higher magnetic field homogeneity but can cause an increase in volume and weight, limiting the application in miniaturization. This article proposes a novel design and shimming method for the Halbach magnet to have not only a lower LDIR but also a better homogeneity. In this article, a multilayer magnetic ring structure was first designed through theoretical calculation and simulation optimization, which compensated for the magnetic field inhomogeneity. Then, a passive shimming method was applied which simulated the first-order and second-order terms of magnetic field inhomogeneity using small magnetic blocks whose magnetization direction was consistent with the main magnetic field. This method has high shimming efficiency and can avoid the demagnetization of the magnetic blocks caused by their magnetization directions against the direction of the main magnetic field, especially when the intensity of the magnetic field is close to or beyond the remanence of the magnetic blocks. The magnetic field intensity of the proposed magnet is 1.08T and the homogeneity reaches close to the sub-ppm. The performance of the magnet was verified in the portable magnetic resonance imaging (MRI) system combined with a set of homemade lowpower gradient coils. MRI images of phantoms and okra reached a resolution of 156 mu m [pixel size 156 mu m, matrix 128 x 128, and field-of-view (FOV) 20 x 20 mm(2)], which shows the potential for wide application of the proposed design and shimming method.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Desktop NMR and Its Applications From Materials Science To Organic Chemistry
    Bluemich, Bernhard
    Singh, Kawarpal
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (24) : 6996 - 7010
  • [2] Blumler P., 2016, MOBILE NMR AND MRI
  • [3] Active shimming method for a 21.3 MHz small-animal MRI magnet
    Chen, Shanshan
    Xia, Tian
    Miao, Zhiying
    Xu, Luoyuan
    Wang, Hongzhi
    Dai, Shuguang
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [4] On-Line Monitoring of Chemical Reactions by using Bench-Top Nuclear Magnetic Resonance Spectroscopy
    Danieli, E.
    Perlo, J.
    Duchateau, A. L. L.
    Verzijl, G. K. M.
    Litvinov, V. M.
    Bluemich, B.
    Casanova, F.
    [J]. CHEMPHYSCHEM, 2014, 15 (14) : 3060 - 3066
  • [5] Small Magnets for Portable NMR Spectrometers
    Danieli, Ernesto
    Perlo, Juan
    Bluemich, Bernhard
    Casanova, Federico
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (24) : 4133 - 4135
  • [6] Mobile sensor for high resolution NMR spectroscopy and imaging
    Danieli, Ernesto
    Mauler, Joerg
    Perlo, Juan
    Bluemich, Bernhard
    Casanova, Federico
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (01) : 80 - 87
  • [7] DESIGN OF PERMANENT MULTIPOLE MAGNETS WITH ORIENTED RARE-EARTH COBALT MATERIAL
    HALBACH, K
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (01): : 1 - 10
  • [8] HALBACH K, 1979, B AM PHYS SOC, V24, P183
  • [9] Development of a mobile magnetic resonance imaging system for outdoor tree measurements
    Kimura, Takeshi
    Geya, Yuto
    Terada, Yasuhiko
    Kose, Katsumi
    Haishi, Tomoyuki
    Gemma, Hiroshi
    Sekozawa, Yoshihiko
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (05)
  • [10] A Ferromagnetic Shimming Method for NMR/MRI Magnets Adopting Two Consecutive Optimization Techniques: Linear Programming and Evolution Strategy
    Lee, Sangjin
    Hahn, Seungyong
    Sim, Kideok
    [J]. JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2011, 24 (1-2) : 1037 - 1043