Simultaneous determination of paclobutrazol and myclobutanil enantiomers in water and soil using enantioselective reversed-phase liquid chromatography

被引:17
|
作者
Tian, Qin [1 ]
Zhou, Zhiqiang [2 ]
Lv, Chunguang [2 ]
Huang, Yi [1 ]
Ren, Liping [3 ]
机构
[1] Natl Res Ctr Geoanal, Beijing 100037, Peoples R China
[2] China Agr Univ, Dept Appl Chem, Coll Sci, Beijing 100094, Peoples R China
[3] China Agr Univ, Coll Anim Sci & Technol, Beijing 100094, Peoples R China
关键词
TANDEM MASS-SPECTROMETRY; CHIRAL STATIONARY PHASES; GAS CHROMATOGRAPHY; PESTICIDES; MICROEXTRACTION; RESOLUTION; RESIDUES; SAMPLES;
D O I
10.1039/c0ay00187b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive reversed phase-liquid chromatography (RP-LC) method for the simultaneous separation and determination of paclobutrazol and myclobutanil enantiomers in water and soil was developed. The method involved a solid phase extraction of paclobutrazol and myclobutanil enantiomers from water and soil by using C-18 Bond-Elut column. The LC system consisted of a reversed phase cellulose tris-3,5-dimethylphenyl carbamate (CDMPC) chiral stationary phase (CSP) with a mobile phase of methanol-water with UV detection. The calibration curve for each enantiomer was linear from 0.5-20 mu g mL(-1). Under suitable conditions, recoveries for all enantiomers were above 75% at two concentration levels in water and soil. Within-day and day-to-day assay precisions (RSDs. %) were below 9% for each enantiomer at concentrations of 0.5, 1.0, 5.0 mu g mL(-1). The method precisions (RSDs, %) were in the range of 3.83-11.5%. The limit of quantification (LOQ) of each enantiomer was 0.0025 mu g mL(-1) using 200.0 ml of water and 0.020 mu g g(-1) using 25.0 g of soil. The limit of detection (LOD) for each enantiomer in water was 0.0015 mu g mL(-1) and in soil 0.012 mu g g(-1) (S/N = 3). In addition, circular dichroism (CD) and UV spectra were obtained by stopped How scanning.
引用
收藏
页码:617 / 622
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of seven naphthalenediols in cosmetics by reversed-phase high performance liquid chromatography
    Chen Lijian
    Huang Jinfeng
    He Minheng
    Lin Senyu
    Guo Xindong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (06) : 630 - 634
  • [22] SIMULTANEOUS DETERMINATION OF BIURET, TRIURET, AND METHYLENEDIUREA IN UREA BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    MURRAY, TP
    AUSTIN, ER
    HOWARD, RG
    HORN, RC
    ANALYTICAL CHEMISTRY, 1982, 54 (09) : 1504 - 1507
  • [23] Simultaneous Determination of Polyacetylene Components in Cangzhu by Reversed-Phase High Performance Liquid Chromatography
    Chen Yanming
    Chou Guixin
    Wang Zhengtao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (01) : 84 - 87
  • [24] SIMULTANEOUS DETERMINATION OF PROPRANOLOL AND 4-HYDROXYPROPRANOLOL ENANTIOMERS AFTER CHIRAL DERIVATIZATION USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCHAEFER, HG
    SPAHN, H
    LOPEZ, LM
    DERENDORF, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02): : 351 - 359
  • [25] Enantioselective determination of phenthoate enantiomers in plant-origin matrices using reversed-phase high-performance liquid chromatography-tandem mass spectrometry
    Dong, Chao
    Zhou, Jie
    Zuo, Wei
    Li, Zhixia
    Li, Jing
    Jiao, Bining
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (01)
  • [26] SIMULTANEOUS CATION AND REVERSED-PHASE CHROMATOGRAPHY
    OKADA, T
    JOURNAL OF CHROMATOGRAPHY, 1992, 607 (01): : 135 - 138
  • [27] Enantioselective determination of oxprenolol in human plasma using dialysis coupled on-line to reversed-phase chiral liquid chromatography
    Ceccato, A
    Toussaint, B
    Chiap, P
    Hubert, P
    Crommen, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) : 1365 - 1374
  • [28] Simultaneous determination of ascorbic acid and caffeine in commercial soft drinks using reversed-phase ultraperformance liquid chromatography
    Turak, Fatma
    Guzel, Remziye
    Dinc, Erdal
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2017, 25 (02) : 285 - 292
  • [29] Simultaneous determination of silicon and phosphorus in soil and plants by reversed-phase ion-pair chromatography
    Hou, Shengjie
    Ding, Mingyu
    Zhu, Jiang
    TALANTA, 2008, 75 (01) : 178 - 182
  • [30] DETERMINATION OF ATRAZINE IN WATER USING TANDEM HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY AND REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    THOMAS, DH
    BECKWESTERMEYER, M
    HAGE, DS
    ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3823 - 3829