Comparison of Baseline, Bone-Subtracted, and Enhanced Chest Radiographs for Detection of Pneumothorax

被引:5
作者
Homayounieh, Fatemeh [1 ,2 ]
Digumarthy, Subba R. [1 ,2 ]
Febbo, Jennifer A. [1 ,2 ]
Garrana, Sherief [1 ,2 ]
Nitiwarangkul, Chayanin [3 ]
Singh, Ramandeep [1 ,2 ]
Khera, Ruhani Doda [1 ,2 ]
Gilman, Matthew [1 ,2 ]
Kalra, Mannudeep K. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, 75 Blossom Court,Room 248, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA USA
[3] Ramathibodi Hosp, Dept Diagnost & Therapeut Radiol, Bangkok, Thailand
来源
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES | 2021年 / 72卷 / 03期
关键词
pneumothorax; CXR; unprocessed; bone-subtracted; enhanced; NODULES;
D O I
10.1177/0846537120908852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess and compare detectability of pneumothorax on unprocessed baseline, single-energy, bone-subtracted, and enhanced frontal chest radiographs (chest X-ray, CXR). Method and Materials: Our retrospective institutional review board-approved study included 202 patients (mean age 53 +/- 24 years; 132 men, 70 women) who underwent frontal CXR and had trace, moderate, large, or tension pneumothorax. All patients (except those with tension pneumothorax) had concurrent chest computed tomography (CT). Two radiologists reviewed the CXR and chest CT for pneumothorax on baseline CXR (ground truth). All baseline CXR were processed to generate bone-subtracted and enhanced images (ClearRead X-ray). Four radiologists (R1-R4) assessed the baseline, bone-subtracted, and enhanced images and recorded the presence of pneumothorax (side, size, and confidence for detection) for each image type. Area under the curve (AUC) was calculated with receiver operating characteristic analyses to determine the accuracy of pneumothorax detection. Results: Bone-subtracted images (AUC: 0.89-0.97) had the lowest accuracy for detection of pneumothorax compared to the baseline (AUC: 0.94-0.97) and enhanced (AUC: 0.96-0.99) radiographs (P < .01). Most false-positive and false-negative pneumothoraces were detected on the bone-subtracted images and the least numbers on the enhanced radiographs. Highest detection rates and confidence were noted for the enhanced images (empiric AUC for R1-R4 0.96-0.99). Conclusion: Enhanced CXRs are superior to bone-subtracted and unprocessed radiographs for detection of pneumothorax.
引用
收藏
页码:519 / 524
页数:6
相关论文
共 10 条
[1]   Management of spontaneous pneumothorax - An American College of Chest Physicians Delphi Consensus Statement [J].
Baumann, MH ;
Strange, C ;
Heffner, JE ;
Light, R ;
Kirby, TJ ;
Klein, J ;
Luketich, JD ;
Panacek, EA ;
Sahn, SA .
CHEST, 2001, 119 (02) :590-602
[2]   Enhancement of chest radiographs obtained in the intensive care unit through bone suppression and consistent processing [J].
Chen, Sheng ;
Zhong, Sikai ;
Yao, Liping ;
Shang, Yanfeng ;
Suzuki, Kenji .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06) :2283-2301
[3]   Lung Nodules: Improved Detection with Software That Suppresses the Rib and Clavicle on Chest Radiographs [J].
Freedman, Matthew Thomas ;
Lo, Shih-Chung Benedict ;
Seibel, John C. ;
Bromley, Christina M. .
RADIOLOGY, 2011, 260 (01) :265-273
[4]   Enhanced pneumothorax visualization in ICU patients using portable chest radiography [J].
Ley-Zaporozhan, Julia ;
Shoushtari, Hassan ;
Menezes, Ravi ;
Zelovitzky, Leon ;
Odedra, Devang ;
Jimenez-Juan, Laura ;
Brunet, Karyn ;
Karimzad, Yasser ;
Paul, Narinder S. .
PLOS ONE, 2018, 13 (12)
[5]   Improved detection of focal pneumonia by chest radiography with bone suppression imaging [J].
Li, Feng ;
Engelmann, Roger ;
Pesce, Lorenzo ;
Armato, Samuel G., III ;
MacMahon, Heber .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2729-2735
[6]  
Omar Hesham R, 2010, J Trauma Manag Outcomes, V4, P12, DOI 10.1186/1752-2897-4-12
[7]   Computer-aided detection in chest radiography based on artificial intelligence: a survey [J].
Qin, Chunli ;
Yao, Demin ;
Shi, Yonghong ;
Song, Zhijian .
BIOMEDICAL ENGINEERING ONLINE, 2018, 17
[8]   Bone suppressed images improve radiologists' detection performance for pulmonary nodules in chest radiographs [J].
Schalekamp, Steven ;
van Ginneken, Bram ;
Meiss, Louis ;
Peters-Bax, Liesbeth ;
Quekel, Lorentz G. B. A. ;
Snoeren, Miranda M. ;
Tiehuis, Audrey M. ;
Wittenberg, Rianne ;
Karssemeijer, Nico ;
Schaefer-Prokop, Cornelia M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) :2399-2405
[9]   Deep learning in chest radiography: Detection of findings and presence of change [J].
Singh, Ramandeep ;
Kalra, Mannudeep K. ;
Nitiwarangkul, Chayanin ;
Patti, John A. ;
Homayounieh, Fatemeh ;
Padole, Atul ;
Rao, Pooja ;
Putha, Preetham ;
Muse, Victorine V. ;
Sharma, Amita ;
Digumarthy, Subba R. .
PLOS ONE, 2018, 13 (10)
[10]   Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneumothorax: Impact of Reader Expertise and Medical Specialty [J].
Urbaneja, Ayla ;
Dodin, Gauthier ;
Hossu, Gabriela ;
Bakour, Omar ;
Kechidi, Rachid ;
Teixeira, Pedro Gondim ;
Blum, Alain .