Review of present method of glucose from human blood and body fluids assessment

被引:42
作者
Fiedorova, Klara [1 ]
Augustynek, Martin [1 ]
Kubicek, Jan [1 ]
Kudrna, Petr [2 ]
Bibbo, Daniele [3 ]
机构
[1] VSB Tech Univ Ostrava, Fac Elect Engn & Comp Sci, Dept Cybernet & Biomed Engn, 17 Listopadu 2172-15, Ostrava 70800, Poruba, Czech Republic
[2] Czech Tech Univ, Fac Biomed Engn, Dept Biomed Technol, Nam Sitna 3105, Kladno 27201, Czech Republic
[3] Univ Roma Tre, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
关键词
Glycemic control; Glucose monitoring; Continuous glucose monitoring (CGM); Glucose selfmonitoring (SMBG); Non-invasive measurement glucose; ARTIFICIAL ENDOCRINE PANCREAS; SURFACE-PLASMON RESONANCE; INSULIN DELIVERY-SYSTEM; LIQUID-CHROMATOGRAPHY; GLYCEMIC CONTROL; DIABETES MANAGEMENT; MONITORING-SYSTEM; OXIDASE; SENSOR; CARE;
D O I
10.1016/j.bios.2022.114348
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
the work has been aimed to create an overview of available and used methods and ways to determine the concentration of glucose in body fluids, especially from a technical point of view. It also provides an overview of the clinical features of these methods. The survey found that today's market offers a large number of options and approaches to the issue. There are accurate reference laboratory methods, self-monitoring methods for measuring glucose levels using glucometers, or continuous methods for daily monitoring of blood glucose trends and for insulin pump control. However, it must not be forgotten that the development of full closure of feedback is still not complete today. Individual methods cannot always be compared with each other, precisely because of the focus and the use of these methods. Choosing the right method of blood glucose levels in the body measuring can help patients to manage their diabetes mellitus. The methods listed in the overview are divided in terms of measurement continuity and further according to the invasiveness of the method. Finally, the issues of accuracy in the detection of glycaemia variability and the possibility of further development of these methods are discussed, as it is clear from the survey that the development is focused mainly on continuous methods improving that get to the forefront and also on developing a biosensor that is purely non-invasive and continuous.
引用
收藏
页数:24
相关论文
共 297 条
  • [1] Abd Salam N. A. B., 2016, J TELECOMMUNICATION, V8, P59
  • [2] Acciaroli G., 2020, GLUCOSE MONITORING D, P173
  • [3] COTS-Based Architectural Framework for Reliable Real-Time Control Applications in Manufacturing
    Adam, George K.
    Petrellis, Nikos
    Garani, Georgia
    Stylianos, Tilemachos
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [4] Correlation between capillary and venous blood glucose levels in diabetic patients
    Adnan, Muhammad
    Imam, Fakhar
    Shabbir, Iffat
    Ali, Zahra
    Rahat, Tayyaba
    [J]. ASIAN BIOMEDICINE, 2015, 9 (01) : 55 - 59
  • [5] A Personal Glucose Meter for Label-Free and Washing-Free Biomolecular Detection
    Ahn, Jun Ki
    Kim, Hyo Yong
    Park, Ki Soo
    Park, Hyun Gyu
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (19) : 11340 - 11343
  • [6] Akande T., 2018, J ADV MED MED RES, P1
  • [7] CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS
    ALBISSER, AM
    LEIBEL, BS
    EWART, TG
    DAVIDOVAC, Z
    BOTZ, CK
    ZINGG, W
    SCHIPPER, H
    GANDER, R
    [J]. DIABETES, 1974, 23 (05) : 397 - 404
  • [8] Ali I.A, 2020, J DIABETES, V1, P5
  • [9] Glycemic Targets: Standards of Medical Care in Diabetes-2020
    不详
    [J]. DIABETES CARE, 2020, 43 : S66 - S76
  • [10] Biocompatibility of implants: lymphocyte/macrophage interactions
    Anderson, James M.
    McNally, Amy K.
    [J]. SEMINARS IN IMMUNOPATHOLOGY, 2011, 33 (03) : 221 - 233