Extramedullary fixation of 569 unstable intertrochanteric fractures -: A randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems

被引:50
作者
Lunsjö, K [1 ]
Ceder, L
Thorngren, KG
Skytting, B
Tidermark, J
Berntson, PO
Allvin, I
Norberg, S
Hjalmars, K
Larsson, S
Knebel, R
Hauggaard, A
Stigsson, L
机构
[1] Helsingborh Hosp, Dept Orthopaed, SE-25187 Helsingborg, Sweden
[2] Univ Lund Hosp, SE-22185 Lund, Sweden
[3] South Hosp, SE-18883 Stockholm, Sweden
[4] Falun Hosp, SE-79182 Falun, Sweden
[5] Orebro Reg Hosp, SE-70185 Orebro, Sweden
[6] Sundsvall Hosp, SE-85186 Sundsvall, Sweden
[7] Ostersund Hosp, SE-83133 Ostersund, Sweden
[8] Univ Uppsala Hosp, SE-75185 Uppsala, Sweden
[9] Malmo Univ Hosp, SE-20502 Malmo, Sweden
[10] Helsingborh Hosp, Dept Radiol, SE-25187 Helsingborg, Sweden
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2001年 / 72卷 / 02期
关键词
D O I
10.1080/000164701317323372
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the efficacy of the Medoff sliding plate (MSP) with 3 other screw-plate systems for fixation of unstable intertrochanteric fractures in a randomized multicenter trial of 569 elderly patients, The MSP has biaxial dynamic capacity along both the neck and the shaft of the femur unlike the other systems, which lack dynamic capacity along the shaft. 268 fractures were operated on with the MSP, and 301 with the dynamic hip screw (DHS), with or without a trochanteric stabilizing plate (DHS/TSP) or with the dynamic condylar screw (DCS), The MSP had recently been shown to the surgeons,The patients in the groups were similar as regards age, domestic situation, preinjury walking ability and type of fracture. We followed the patients clinically and radiographically for at least 1 year. There was no significant difference in walking ability at follow-up or rate of return to home. Fixation failure occurred in 18/268 fractures operated on with the MSP, in 8/238 with the DHS, in 3/49 with the DHS/TSP and in 1/14 with the DCS, The difference in the rate of fixation failure was not statistically significant when the MSP group was compared to the 3 other groups. In 14 of the 18 fixation failures in the MSP group, the biaxial dynamic capacity of the MSP had not been used due to technical errors by surgeons, unfamiliar with the new method, No selection bias was found regarding fracture types in the 2 subgroups of patients with correct or inadequate biaxial dynamization, Extramedullary fixation of unstable intertrochanteric fractures with these implants showed a low failure rate. When using the MSP, biaxial dynamization must be correctly performed.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 19 条
[1]  
BANNISTER GC, 1990, CLIN ORTHOP RELAT R, P242
[2]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[3]   RAB-plate vs Richards CHS plate for unstable trochanteric hip fractures - A randomized study of 233 patients with 1-year follow-up [J].
Buciuto, R ;
Uhlin, B ;
Hammerby, S ;
Hammer, R .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (01) :25-28
[4]  
Ceder L, 1996, ORTHOP T, V20, P162
[5]   UNSTABLE INTERTROCHANTERIC FRACTURE OF THE FEMUR - A PROSPECTIVE RANDOMIZED STUDY COMPARING ANATOMICAL REDUCTION AND MEDIAL DISPLACEMENT OSTEOTOMY [J].
DESJARDINS, AL ;
ROY, A ;
PAIEMENT, G ;
NEWMAN, N ;
PEDLOW, F ;
DESLOGES, D ;
TURCOTTE, RE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :445-447
[6]   TROCHANTERIC FEMORAL FRACTURES TREATED WITH MCLAUGHLIN OSTEOSYNTHESIS [J].
JENSEN, JS ;
MICHAELSEN, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1975, 46 (05) :795-803
[7]   STABLE TROCHANTERIC FRACTURES - A COMPARATIVE-ANALYSIS OF 4 METHODS OF INTERNAL-FIXATION [J].
JENSEN, JS ;
TONDEVOLD, E ;
SONNEHOLM, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (05) :811-816
[8]   FRACTURES OF THE PROXIMAL PART OF THE FEMUR [J].
KYLE, RF ;
CABANELA, ME ;
RUSSELL, TA ;
SWIONTKOWSKI, MF ;
WINQUIST, RA ;
ZUCKERMAN, JD ;
SCHMIDT, AH ;
KOVAL, KJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (06) :924-950
[9]   GAMMA-NAILS AND DYNAMIC HIP SCREWS FOR PERITROCHANTERIC FRACTURES - A RANDOMIZED PROSPECTIVE-STUDY IN ELDERLY PATIENTS [J].
LEUNG, KS ;
SO, WS ;
SHEN, WY ;
HUI, PW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :345-351
[10]   Two-way compression along the shaft and the neck of the femur with the Medoff sliding plate - One-year follow-up of 108 intertrochanteric fractures [J].
Lunsjo, K ;
Ceder, L ;
Stigsson, L ;
Hauggaard, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :387-390