Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

被引:171
作者
Tipper, G
U-King-Im, JM
Price, SJ
Trivedi, RA
Cross, JJ
Higgins, NJ
Farmer, R
Wat, J
Kirollos, R
Kirkpatrick, PJ
Antoun, NM
Gillard, JH
机构
[1] Univ Dept Radiol, Addenbrookes Hosp, Cambridge CB2 2QQ, England
[2] Addenbrookes Hosp, Acad Neurosurg Unit, Cambridge CB2 2QQ, England
关键词
computed tomography (CT); angiography; subarachnoid haemorrhage; intracranial aneurysm;
D O I
10.1016/j.crad.2004.09.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe. (c) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:565 / 572
页数:8
相关论文
共 19 条
  • [1] Computed tomographic angiography versus digital subtraction angiography for the diagnosis and early treatment of ruptured intracranial aneurysms
    Anderson, GB
    Steinke, DE
    Petruk, KC
    Ashforth, R
    Findlay, JM
    [J]. NEUROSURGERY, 1999, 45 (06) : 1315 - 1320
  • [2] Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis
    Chappell, ET
    Moure, FC
    Good, MC
    [J]. NEUROSURGERY, 2003, 52 (03) : 624 - 630
  • [3] Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team
    Hoh, BL
    Cheung, AC
    Rabinov, JD
    Pryor, JC
    Carter, BS
    Ogilvy, CS
    [J]. NEUROSURGERY, 2004, 54 (06) : 1329 - 1340
  • [4] Multi-detector CT angiography of the intra-cranial circulation: normal anatomy and pathology with angiographic correlation
    Jayaraman, MV
    Mayo-Smith, WW
    [J]. CLINICAL RADIOLOGY, 2004, 59 (08) : 690 - 698
  • [5] Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA
    Jayaraman, MV
    Mayo-Smith, WW
    Tung, GA
    Haas, RA
    Rogg, JM
    Mehta, NR
    Doberstein, CE
    [J]. RADIOLOGY, 2004, 230 (02) : 510 - 518
  • [6] Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed tomographic angiography
    Kangasniemi, M
    Mäkelä, T
    Koskinen, S
    Porras, M
    Poussa, K
    Hernesniemi, J
    [J]. NEUROSURGERY, 2004, 54 (02) : 336 - 340
  • [7] Intracranial aneurysms: Detection with three-dimensional CT angiography with volume rendering - Comparison with conventional angiographic and surgical findings
    Korogi, Y
    Takahashi, M
    Katada, K
    Ogura, Y
    Hasuo, K
    Ochi, M
    Utsunomiya, H
    Abe, T
    Imakita, S
    [J]. RADIOLOGY, 1999, 211 (02) : 497 - 506
  • [8] Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms
    Missler, U
    Hundt, C
    Wiesmann, M
    Mayer, T
    Brückmann, H
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (04) : 564 - 568
  • [9] Computerized tomography angiography in patients with subarachnoid hemorrhage: from aneurysm detection to treatment without conventional angiography
    Velthuis, BK
    van Leeuwen, MS
    Witkamp, TD
    Ramos, LMP
    van der Sprenkel, JMB
    Rinkel, GJE
    [J]. JOURNAL OF NEUROSURGERY, 1999, 91 (05) : 761 - 767
  • [10] Surgical anatomy of the cerebral arteries in patients with subarachnoid hemorrhage: comparison of computerized tomography angiography and digital subtraction angiography
    Velthuis, BK
    van Leeuwen, MS
    Witkamp, TD
    Ramos, LMP
    van der Sprenkel, JWB
    Rinkel, GJE
    [J]. JOURNAL OF NEUROSURGERY, 2001, 95 (02) : 206 - 212