Performance of Multilayer Monochromators for Hard X-Ray Imaging with Coherent Synchrotron Radiation

被引:10
作者
Dietsch, R. [1 ]
Rack, A. [4 ]
Weitkamp, T. [4 ]
Riotte, M. [5 ]
Rack, T. [5 ]
Holz, T. [1 ]
Kraemer, M. [1 ]
Weissbach, D. [1 ]
Morawe, Ch. [4 ]
Siewert, F. [2 ]
Meduna, M. [3 ]
Cloetens, P. [4 ]
Ziegler, E. [4 ]
机构
[1] AXO DRESDEN GmbH, Winterbergstr 28, D-01277 Dresden, Germany
[2] Helmholtz Zentrum Berlin, Berlin, Germany
[3] Masaryk Univ, Brno, Czech Republic
[4] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[5] Karlsruhe Inst Technol, D-76021 Karlsruhe, Germany
来源
10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY | 2011年 / 1365卷
关键词
X-ray imaging; x-ray optics; multilayer mirrors; synchrotron radiation; coherence; x-ray monochromators; x-ray phase contrast; TOMOGRAPHY; BEAMLINE; MICROTOMOGRAPHY; RADIOGRAPHY; BESSY;
D O I
10.1063/1.3625308
中图分类号
TH742 [显微镜];
学科分类号
摘要
We present a study in which multilayers of different periodicity (from 2.5 to 5.5 nm), composition (W/Si, Mo/Si, Pd/B4C, Ru/B4C), and numbers of layers have been compared. Particularly, we chose mirrors with similar intrinsic quality (roughness and reflectivity) to study their performance (flatness and coherence of the outgoing beam) as monochromators in synchrotron radiography. The results indicate that material composition is the dominating factor for the performance. This is important to consider for future developments in synchrotron-based hard x-ray imaging methods. In these techniques, multilayer monochromators are popular because of their good tradeoff between spectral bandwidth and photon flux density of the outgoing beam, but sufficient homogeneity and preservation of the coherent properties of the reflected beam are major concerns. The experimental results we collected may help scientists and engineers specify multilayer monochromators and can contribute to better exploitation of the advantages of multilayer monochromators in microtomography and other full-field imaging techniques.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 28 条
[1]  
Banhart J., 2008, ADV TOMOGRAPHIC METH
[2]  
BROOKS R A, 1976, Medical Physics (Woodbury), V3, P237, DOI 10.1118/1.594240
[3]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[4]   Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays [J].
Cloetens, P ;
Ludwig, W ;
Baruchel, J ;
Van Dyck, D ;
Van Landuyt, J ;
Guigay, JP ;
Schlenker, M .
APPLIED PHYSICS LETTERS, 1999, 75 (19) :2912-2914
[5]   Fractional Talbot imaging of phase gratings with hard x rays [J].
Cloetens, P ;
Guigay, JP ;
DeMartino, C ;
Baruchel, J ;
Schlenker, M .
OPTICS LETTERS, 1997, 22 (14) :1059-1061
[6]   Large area PLD of nanometer-multilayers [J].
Dietsch, R ;
Holz, T ;
Weissbach, D ;
Scholz, R .
APPLIED SURFACE SCIENCE, 2002, 197 :169-174
[7]   OBSERVATIONAL STRATEGIES FOR 3-DIMENSIONAL SYNCHROTRON MICROTOMOGRAPHY [J].
FLANNERY, BP ;
ROBERGE, WG .
JOURNAL OF APPLIED PHYSICS, 1987, 62 (12) :4668-4674
[8]   In situ investigation of the discharge of alkaline Zn-MnO2 batteries with synchrotron x-ray and neutron tomographies [J].
Manke, I. ;
Banhart, J. ;
Haibel, A. ;
Rack, A. ;
Zabler, S. ;
Kardjilov, N. ;
Hilger, A. ;
Melzer, A. ;
Riesemeier, H. .
APPLIED PHYSICS LETTERS, 2007, 90 (21)
[9]   The new ESRF multilayer deposition facility [J].
Morawe, Ch. ;
Borel, Ch. ;
Peffen, J-Ch. .
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705
[10]   Thickness control of large area x-ray multilayers [J].
Morawe, Ch. ;
Peffen, J-Ch. .
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IV, 2009, 7448