Micro sequential injection: environmental monitoring of nitrogen and phosphate in water using a "Lab-on-Valve" system furnished with a microcolumn

被引:46
作者
Wu, CH [1 ]
Ruzicka, J [1 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
D O I
10.1039/b104305f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A "Lab-on-Valve" manifold operated in the micro sequential injection (mu SI) mode was adopted to accommodate EPA-approved methods for spectrophotometric determinations of nitrate, nitrite and orthophosphate in the ppb (N or P) concentration range. A computer programmable mu SI protocol, utilizing stopped-flow within a copperized Cd-foil filled microcolumn was developed for nitrate reduction to nitrite with subsequent colorimetric measurement, yielding concentration ranges for nitrate of 100.0-4000.0 ppb (N) and for nitrite of 30.0-4000.0 ppb (N) and linear calibration responses of r(2) = 0.9999 for nitrate and 0.9995 for nitrite. Using a stopped-flow reaction rate measurement, phosphate was determined in the range 1.0-30.0 ppb (P) with a calibration response of r(2) = 0.9997. The technical improvement of this methodology, apart from micro miniaturization, is the use of the stopped-flow technique, that resulted in improved detection limits and allowed reagent consumption to be reduced 1500-fold compared with conventional procedure while the amount of metallic cadmium was reduced 20-fold compared with the EPA-approved continuous-flow assay.
引用
收藏
页码:1947 / 1952
页数:6
相关论文
共 13 条
  • [2] Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite
    Cerdà, A
    Oms, MT
    Forteza, R
    Cerdà, V
    [J]. ANALYTICA CHIMICA ACTA, 1998, 371 (01) : 63 - 71
  • [3] FLOW-INJECTION VOLTAMMETRIC DETERMINATION OF PHOSPHATE - DIRECT INJECTION OF PHOSPHATE INTO MOLYBDATE REAGENT
    FOGG, AG
    BSEBSU, NK
    [J]. ANALYST, 1982, 107 (1274) : 566 - 570
  • [4] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS
    GINE, MF
    BERGAMIN, H
    ZAGATTO, EAG
    REIS, BF
    [J]. ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 191 - 197
  • [5] Marczenko Z., 1986, SEPARATION SPECTROPH
  • [6] ERROR SOURCES IN SIMULTANEOUS NITRATE NITRITE DETERMINATIONS USING COPPERISED CADMIUM AS NITRATE-REDUCING AGENT
    NOVIC, M
    TEZAK, S
    PIHLAR, B
    HUDNIK, V
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (10-11): : 653 - 655
  • [7] SEQUENTIAL INJECTION-ANALYSIS OF NITRITES AND NITRATES
    OMS, MT
    CERDA, A
    CERDA, V
    [J]. ANALYTICA CHIMICA ACTA, 1995, 315 (03) : 321 - 330
  • [8] PAVON JLP, 1990, ANAL CHEM, V62, P2405
  • [9] Ruzicka J, 2000, MESA MG, P1
  • [10] Lab-on-valve: universal microflow analyzer based on sequential and bead injection
    Ruzicka, J
    [J]. ANALYST, 2000, 125 (06) : 1053 - 1060