Application of TOPSIS method in evaluating the effects of supply vane angle of a task/ambient air conditioning system on energy utilization and thermal comfort

被引:97
作者
Mao Ning [1 ]
Song Mengjie [2 ,3 ]
Deng Shiming [4 ]
机构
[1] China Univ Petr East China, Coll Pipeline & Civil Engn, Qingdao, Shandong, Peoples R China
[2] Guangdong Univ Technol, Sch Mat & Energy, Guangdong Prov Key Lab Funct Soft Condensed Matte, Guangzhou, Guangdong, Peoples R China
[3] Hong Kong Univ Sci & Technol, Dept Mech & Aerosp Engn, Hong Kong, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Task/ambient air conditioning system; Energy utilization coefficient; Thermal comfort; TOPSIS method; CFD; COMPUTATIONAL FLUID-DYNAMICS; INDOOR ENVIRONMENT; ORDER PREFERENCE; BUILDING DESIGN; HUMAN-BODY; PERFORMANCE; CFD; VENTILATION; OPTIMIZATION; SIMILARITY;
D O I
10.1016/j.apenergy.2016.08.011
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In subtropical area, air conditioning (A/C) is widely used to provide a suitable thermal indoor environment. During operation, many parameters or configurations may influence the performance of the A/C system. Among them, the supply vane angle is an important factor, which can influence the energy saving and thermal comfort level in the occupied zone, according to previously related studies. However, it was revealed that it was difficult to get a balance between these two aspects. Therefore, based on the previous study, this further study was conducted aiming to determine the suitable angle to achieve the best performance. Hence, the technique for order preferences by similarity to an ideal solution (TOPSIS) method was used to calculate the combined performance considering energy saving and thermal comfort. Finally, the best supply vane angle of 30 inverted perpendicular, with the energy utilization coefficient (EUC) and draft risk (DR) at the values of 1.28 and 8.89, was obtained, at which the A/C system achieved a medium energy saving performance and a lower draft risk. It's indicated that using TOPSIS method can help tackle with conflicting effects for A/C systems in buildings. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:536 / 545
页数:10
相关论文
共 42 条
  • [21] Seasonal variations in residential and commercial sector electricity consumption in Hong Kong
    Lam, Joseph C.
    Tang, H. L.
    Li, Danny H. W.
    [J]. ENERGY, 2008, 33 (03) : 513 - 523
  • [22] Evaluating and ranking the energy performance of office building using technique for order preference by similarity to ideal solution
    Lee, Wen-Shing
    Lin, Lung-Chieh
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (16) : 3521 - 3525
  • [23] CFD study of the thermal environment in an air-conditioned train station building
    Li, Qiong
    Yoshino, Hiroshi
    Mochida, Akashi
    Lei, Bo
    Meng, Qinglin
    Zhao, Lihua
    Lun, Yufat
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1452 - 1465
  • [24] Computational fluid dynamics (CFD) modelling of air flow field, mean age of air and CO2 distributions inside a bedroom with different heights of conditioned air supply outlet
    Mao Ning
    Song Mengjie
    Chan Mingyin
    Pan Dongmei
    Deng Shiming
    [J]. APPLIED ENERGY, 2016, 164 : 906 - 915
  • [25] Thermal, ventilation and energy saving performance evaluations of a ductless bed-based task/ambient air conditioning (TAC) system
    Mao Ning
    Pan Dongmei
    Deng Shiming
    Chan Mingyin
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 297 - 305
  • [26] Experimental and numerical studies on the performance evaluation of a bed-based task/ambient air conditioning (TAC) system
    Ning, Mao
    Dongmei, Pan
    Mingyin, Chan
    Shiming, Deng
    [J]. APPLIED ENERGY, 2014, 136 : 956 - 967
  • [27] Performance evaluation of a novel bed-based task/ambient conditioning (TAC) system
    Pan Dongmei
    Chan Mingyin
    Xia Liang
    Xu Xiangguo
    Deng Shiming
    [J]. ENERGY AND BUILDINGS, 2012, 44 : 54 - 62
  • [28] Evaluation of an improved air distribution system for aircraft cabin
    Pang, Liping
    Xu, Jie
    Fang, Lei
    Gong, Mengmeng
    Zhang, Hua
    Zhang, Yu
    [J]. BUILDING AND ENVIRONMENT, 2013, 59 : 145 - 152
  • [29] Modeling and optimization of R-717 and R-134a ice thermal energy storage air conditioning systems using NSGA-II and MOPSO algorithms
    Randar, Mohammad Hoseini
    Heidari, Mohammad
    Ataei, Abtin
    Choi, Jun-Ki
    [J]. APPLIED THERMAL ENGINEERING, 2016, 96 : 217 - 227
  • [30] Selection and performance assessment of Phase Change Materials for heating, ventilation and air-conditioning applications
    Rastogi, Monisha
    Chauhan, Aditya
    Vaish, Rahul
    Kishan, Anil
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 260 - 269