Coronary calcium scores on dual-source photon-counting computed tomography: an adapted Agatston methodology aimed at radiation dose reduction

被引:21
作者
van der Werf, Niels R. [1 ]
Greuter, Marcel J. W. [2 ,3 ]
Booij, Ronald [1 ]
van der Lugt, Aad [1 ]
Budde, Ricardo P. J. [1 ]
van Straten, Marcel [1 ]
机构
[1] Erasmus MC, Dept Radiol & Nucl Med, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
[3] Univ Twente, Dept Robot & Mechatron, Enschede, Netherlands
关键词
X-ray computed tomography; Calcium; Coronary vessels; Imaging phantoms; Radiation dosage; ARTERY CALCIUM; HEART-RATE; REPRODUCIBILITY; QUANTIFICATION; CALCIFICATION; PERFORMANCE; DISEASE; VESSEL; SIZE;
D O I
10.1007/s00330-022-08642-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to determine mono-energetic (monoE) level-specific photon-counting CT (PCCT) Agatston thresholds, to yield monoE level independent Agatston scores validated with a dynamic cardiac phantom. Also, we examined the potential of dose reduction for PCCT coronary artery calcium (CAC) studies, when reconstructed at low monoE levels. Methods Theoretical CAC monoE thresholds were calculated with data from the National Institute of Standards and Technology (NIST) database. Artificial CAC with three densities were moved in an anthropomorphic thorax phantom at 0 and 60-75 bpm, and scanned at full and 50% dose on a first-generation dual-source PCCT. For all densities, Agatston scores and maximum CT numbers were determined. Agatston scores were compared with the reference at full dose and 70 keV monoE level; deviations (95% confidence interval) < 10% were deemed to be clinically not-relevant. Results Averaged over all monoE levels, measured CT numbers deviated from theoretical CT numbers by 6%, 13%, and - 4% for low-, medium-, and high-density CAC, respectively. At 50% reduced dose and 60-75 bpm, Agatston score deviations were non-relevant for 60 to 100 keV and 60 to 120 keV for medium- and high-density CAC, respectively. Conclusion MonoE level-specific Agatston score thresholds resulted in similar scores as in standard reconstructions at 70 keV. PCCT allows for a potential dose reduction of 50% for CAC scoring using low monoE reconstructions for medium- and high-density CAC.
引用
收藏
页码:5201 / 5209
页数:9
相关论文
共 29 条
[21]   Spectral photon-counting CT in cardiovascular imaging [J].
Sandfort, Veit ;
Persson, Mats ;
Pourmorteza, Amir ;
Noel, Peter B. ;
Fleischmann, Dominik ;
Willemink, Martin J. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) :218-225
[22]   Coronary artery calcium scoring:: Influence of reconstruction interval and reconstruction increment using 64-MDCT [J].
Schlosser, Thomas ;
Hunold, Peter ;
Voigtlaender, Thomas ;
Schmermund, Axel ;
Barkhausen, Joerg .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) :1063-1068
[23]   A phantom study of the effect of heart rate, coronary artery displacement and vessel trajectory on coronary artery calcium score: Potential for risk misclassification [J].
Tigges, Stefan ;
Arepalli, Chesnal D. ;
Tridandapani, Srini ;
Oshinski, John ;
Kurz, Calvin R. ;
Richer, Edward J. ;
Chen, Zhengjia ;
Stillman, Arthur E. ;
Raggi, Paolo .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (04) :260-267
[24]   Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study [J].
van der Werf, N. R. ;
Willemink, M. J. ;
Willems, T. P. ;
Vliegenthart, R. ;
Greuter, M. J. W. ;
Leiner, T. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (06) :959-966
[25]   Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study [J].
van der Werf, Niels R. ;
Booij, Ronald ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Leiner, Tim ;
de Groen, Joel J. ;
Bos, Daniel ;
Budde, Ricardo P. J. ;
Willemink, Martin J. ;
Greuter, Marcel J. W. .
EUROPEAN RADIOLOGY, 2021, 31 (12) :9211-9220
[26]   Fully automated quantification method (FQM) of coronary calcium in an anthropomorphic phantom [J].
van Praagh, Gijs D. ;
van der Werf, Niels R. ;
Wang, Jia ;
van Ommen, Fasco ;
Poelhekken, Keris ;
Slart, Riemer H. J. A. ;
Fleischmann, Dominik ;
Greuter, Marcel J. W. ;
Leiner, Tim ;
Willemink, Martin J. .
MEDICAL PHYSICS, 2021, 48 (07) :3730-3740
[27]   The impact of dose reduction on the quantification of coronary artery calcifications and risk categorization: A systematic review [J].
Vonder, Marleen ;
van der Werf, Niels R. ;
Leiner, Tim ;
Greuter, Marcel J. W. ;
Fleischmann, Dominik ;
Vliegenthart, Rozemarijn ;
Oudkerk, Matthijs ;
Willemink, Martin J. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (05) :352-363
[28]   Photon-counting CT: Technical Principles and Clinical Prospects [J].
Willemink, Martin J. ;
Persson, Mats ;
Pourmorteza, Amir ;
Pelc, Norbert. ;
Fleischmann, Dominik .
RADIOLOGY, 2018, 289 (02) :293-312
[29]   Coronary calcium scores are systematically underestimated at a large chest size: A multivendor phantom study [J].
Willemink, Martin J. ;
Abramiuc, Bronislaw ;
den Harder, Annemarie M. ;
van der Werf, Niels R. ;
de Jong, Pim A. ;
Budde, Ricardo P. J. ;
Wildberger, Joachim E. ;
Vliegenthart, Rozemarijn ;
Willems, Tineke P. ;
Greuter, Marcel J. W. ;
Leiner, Tim .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) :415-421