Detecting penicillin G in milk with impedimetric label-free immunosensor

被引:79
|
作者
Thavarungkul, Panote [1 ,2 ]
Dawan, Supapom [2 ,3 ]
Kanatharana, Proespichaya [2 ,3 ]
Asawatreratanakul, Punnee [2 ,4 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Biophys Res Unit Biosensors & Biocurrents, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
关键词
impedimetric; immunosensor; penicillin G; benzylpenicillin; label-free; flow injection;
D O I
10.1016/j.bios.2007.08.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free impedimetric flow injection immunosensor for the direct detection of penicillin G has been developed. Anti-penicillin G was immobilized on a gold working electrode modified with a self-assembled monolayer of thioctic acid. Real time monitoring of impedance was carried out at the optimum frequency of 160 Hz. Under optimum operating conditions the system provided a wide linear range between 1.0 x 10(-13) and 1.0 x 10(-8) M with a very low detection limit of 3.0 x 10(-15) M, much lower than the MRL of penicillin G in milk (1.2 x 10(-8) M). The immobilized anti-penicillin G on self-assembled thioctic acid monolayer gold electrode was very stable and provided good reproducible signal after regeneration up to 45 times with a relative standard deviation (R.S.D.) lower than 4%. Good recoveries and precisions were obtained when spiked raw milk samples were analyzed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 50 条
  • [31] Development of an enrofloxacin immunosensor based on label-free electrochemical impedance spectroscopy
    Wu, Ching-Chou
    Lin, Chia-Hung
    Wang, Way-Shyan
    TALANTA, 2009, 79 (01) : 62 - 67
  • [32] Label-free voltammetric immunosensor using a nanoporous membrane based platform
    de la Escosura-Muniz, Alfredo
    Merkoci, Arben
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (06) : 859 - 863
  • [33] A new strategy to develop the disposable label-free immunosensor with electrochemiluminescent probing
    Lin, Jiang
    Ya, Yang
    Tu Yifeng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 747 : 136 - 142
  • [34] Label-free detection of bisphenol A using a potentiometric immunosensor
    Piao, Ming-Hua
    Noh, Hui-Bog
    Rahman, Md Aminur
    Won, Mi-Sook
    Shim, Yoon-Bo
    ELECTROANALYSIS, 2008, 20 (01) : 30 - 37
  • [35] Label-free electrochemical immunosensor for sensitive detection of kanamycin
    Zhao, Yanfang
    Wei, Qin
    Xu, Caixia
    Li, He
    Wu, Dan
    Cai, Yanyan
    Mao, Kexia
    Cui, Zhentao
    Du, Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) : 618 - 625
  • [36] Functionalized CVD monolayer graphene for label-free impedimetric biosensing
    Eissa, Shimaa
    Jimenez, Gaston Contreras
    Mahvash, Farzaneh
    Guermoune, Abdeladim
    Tlili, Chaker
    Szkopek, Thomas
    Zourob, Mohammed
    Siaj, Mohamed
    NANO RESEARCH, 2015, 8 (05) : 1698 - 1709
  • [37] Detection of Ochratoxin A by Label-Free Liquid Crystal Immunosensor
    Yang Sheng-Yuan
    Tan Hui
    Liu Yan-Mei
    Wu Zhao-Yang
    Shen Guo-Li
    Yu Ru-Qin
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2011, 32 (05): : 1065 - 1069
  • [38] The effect of gold nanostructure morphology on label-free electrochemical immunosensor design
    Brasiunas, Benediktas
    Popov, Anton
    Kraujelyte, Gabija
    Ramanaviciene, Almira
    BIOELECTROCHEMISTRY, 2024, 156
  • [39] Label-free photoelectrochemical immunosensor for sensitive detection of Ochratoxin A
    Yang, Jiaojiao
    Gao, Picheng
    Liu, Yixin
    Li, Rongxia
    Ma, Hongmin
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 13 - 18
  • [40] Label-free amperometic immunosensor for detection of brucella antibody
    Zuo, Y. (zyueming88@aliyun.com), 1600, Chinese Society of Agricultural Machinery (45): : 243 - 249