Detecting penicillin G in milk with impedimetric label-free immunosensor

被引:79
|
作者
Thavarungkul, Panote [1 ,2 ]
Dawan, Supapom [2 ,3 ]
Kanatharana, Proespichaya [2 ,3 ]
Asawatreratanakul, Punnee [2 ,4 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Biophys Res Unit Biosensors & Biocurrents, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
关键词
impedimetric; immunosensor; penicillin G; benzylpenicillin; label-free; flow injection;
D O I
10.1016/j.bios.2007.08.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free impedimetric flow injection immunosensor for the direct detection of penicillin G has been developed. Anti-penicillin G was immobilized on a gold working electrode modified with a self-assembled monolayer of thioctic acid. Real time monitoring of impedance was carried out at the optimum frequency of 160 Hz. Under optimum operating conditions the system provided a wide linear range between 1.0 x 10(-13) and 1.0 x 10(-8) M with a very low detection limit of 3.0 x 10(-15) M, much lower than the MRL of penicillin G in milk (1.2 x 10(-8) M). The immobilized anti-penicillin G on self-assembled thioctic acid monolayer gold electrode was very stable and provided good reproducible signal after regeneration up to 45 times with a relative standard deviation (R.S.D.) lower than 4%. Good recoveries and precisions were obtained when spiked raw milk samples were analyzed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 50 条
  • [11] Colorectal Cancer Label-Free Impedimetric Immunosensor for Blood-Based Biomarker CCSP-2
    Paul, Ruma
    Morales-Lozada, Yermary
    Colon, Brian J. Sanchez
    Hernandez, Andrea R.
    Roy, Sourav
    Cabrera, Carlos R.
    ACS MEASUREMENT SCIENCE AU, 2025, 5 (01): : 87 - 95
  • [12] Label-Free Impedimetric Immunosensor for Nerve Growth Factor Protein Constructed Using an Automated Dispensing System
    Holford, Timothy R. J.
    Holmes, Joanne L.
    Collyer, Stuart D.
    Davis, Frank
    Higson, Seamus P. J.
    ELECTROANALYSIS, 2013, 25 (07) : 1675 - 1682
  • [13] Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A
    Malvano, Francesca
    Albanese, Donatella
    Crescitelli, Alessio
    Pilloton, Roberto
    Esposito, Emanuela
    BIOSENSORS-BASEL, 2016, 6 (03):
  • [14] A Label-Free Porous Alumina Interferometric Immunosensor
    Alvarez, Sara D.
    Li, Chang-Peng
    Chiang, Casey E.
    Schuller, Ivan K.
    Sailor, Michael J.
    ACS NANO, 2009, 3 (10) : 3301 - 3307
  • [15] Label-Free Amperometric Immunosensor for the Detection of Carbofuran Pesticide
    Sun, Xia
    Wang, Xiangyou
    Du, Shuyuan
    Zhao, Wenping
    Li, Qingqing
    Han, Xiangbo
    SENSOR LETTERS, 2011, 9 (03) : 958 - 963
  • [16] Milk Allergen Detection: Sensitive Label-Free Voltammetric Immunosensor Based on Electropolymerization
    Kilic, Tugba
    Philipp, Paul Jean
    Giavedoni, Paola
    Carrara, Sandro
    BIONANOSCIENCE, 2020, 10 (02) : 512 - 522
  • [17] Ultra trace analysis of small molecule by label-free impedimetric immunosensor using multilayer modified electrode
    Chullasat, Kochaporn
    Kanatharana, Proespichaya
    Limbut, Warakorn
    Numnuam, Apon
    Thavarungkul, Panote
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) : 4571 - 4578
  • [18] Label-free impedimetric immunosensor for detection of the textile azo dye Disperse Red 1 in treated water
    Rocha, Carolina G.
    Ferreira, Antonio A. P.
    Yamanaka, Hideko
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 52 - 59
  • [19] Milk Allergen Detection: Sensitive Label-Free Voltammetric Immunosensor Based on Electropolymerization
    Tugba Kilic
    Paul Jean Philipp
    Paola Giavedoni
    Sandro Carrara
    BioNanoScience, 2020, 10 : 512 - 522
  • [20] Impedimetric immunosensor for the specific label free detection of ciprofloxacin antibiotic
    Ionescu, Rodica E.
    Jaffrezic-Renault, Nicole
    Bouffier, Laurent
    Gondran, Chantal
    Cosnier, Serge
    Pinacho, Daniel G.
    Marco, M. -Pilar
    Sanchez-Baeza, Francisco J.
    Healy, Thomas
    Martelet, Claude