Detecting penicillin G in milk with impedimetric label-free immunosensor

被引:79
作者
Thavarungkul, Panote [1 ,2 ]
Dawan, Supapom [2 ,3 ]
Kanatharana, Proespichaya [2 ,3 ]
Asawatreratanakul, Punnee [2 ,4 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Biophys Res Unit Biosensors & Biocurrents, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
关键词
impedimetric; immunosensor; penicillin G; benzylpenicillin; label-free; flow injection;
D O I
10.1016/j.bios.2007.08.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free impedimetric flow injection immunosensor for the direct detection of penicillin G has been developed. Anti-penicillin G was immobilized on a gold working electrode modified with a self-assembled monolayer of thioctic acid. Real time monitoring of impedance was carried out at the optimum frequency of 160 Hz. Under optimum operating conditions the system provided a wide linear range between 1.0 x 10(-13) and 1.0 x 10(-8) M with a very low detection limit of 3.0 x 10(-15) M, much lower than the MRL of penicillin G in milk (1.2 x 10(-8) M). The immobilized anti-penicillin G on self-assembled thioctic acid monolayer gold electrode was very stable and provided good reproducible signal after regeneration up to 45 times with a relative standard deviation (R.S.D.) lower than 4%. Good recoveries and precisions were obtained when spiked raw milk samples were analyzed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 26 条
[1]   On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy [J].
Bart, M ;
Stigter, ECA ;
Stapert, HR ;
de Jong, GJ ;
van Bennekom, WP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :49-59
[2]   Antibiotic use in animal feed and its impact on human health [J].
Barton, MD .
NUTRITION RESEARCH REVIEWS, 2000, 13 (02) :279-299
[3]   A DNA diagnostic biosensor: development, characterisation and performance [J].
Berney, H ;
West, J ;
Haefele, E ;
Alderman, J ;
Lane, W ;
Collins, JK .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :100-108
[4]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[5]   Development of an optical biosensor assay for detection of β-lactam antibiotics in milk using the penicillin-binding protein 2x [J].
Cacciatore, G ;
Petz, M ;
Rachid, S ;
Hakenbeck, R ;
Bergwerff, AA .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :105-115
[6]  
Commission of the European Communities, 1999, OFF J L, VL60, P16
[7]   Development of an electrochemical immunosensor for direct detection of interferon-γ at the attomolar level [J].
Dijksma, M ;
Kamp, B ;
Hoogvliet, JC ;
van Bennekom, WP .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :901-907
[8]   COMPARISON OF POTENTIOMETRIC ENZYME SENSORS FOR UREA AND PENICILLIN-G - DIFFERENTIAL THICK-FILM SENSORS VERSUS CLASSICAL ELECTRODES [J].
EPPELSHEIM, C ;
AUBECK, R ;
HAMPP, N .
JOURNAL OF MEMBRANE SCIENCE, 1995, 100 (02) :131-137
[9]  
*EUR GUID, 1998, FITN PURP AN METH LA
[10]   Impedimetric biosensors [J].
Guan, JG ;
Miao, YQ ;
Zhang, QJ .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2004, 97 (04) :219-226