Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior

被引:380
作者
Long, CM
Suh, HH
Catalano, PJ
Koutrakis, P
机构
[1] Gradient Corp, Cambridge, MA 02142 USA
[2] Harvard Univ, Dept Environm Hlth, Sch Publ Hlth, Boston, MA 02115 USA
[3] Dana Farber Canc Inst, Dept Biostat Sci, Boston, MA 02115 USA
[4] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
关键词
D O I
10.1021/es001477d
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Because people spend approximately 85-90% of their time indoors, it is widely recognized that a significant portion of total personal exposures to ambient particles occurs in indoor environments. Although penetration efficiencies and deposition rates regulate indoor exposures to ambient particles, few data exist on the levels or variability of these infiltration parameters, in particular for time- and size-resolved data. To investigate ambient particle infiltration, a comprehensive particle characterization study was conducted in nine nonsmoking homes in the metropolitan Boston area. Continuous indoor and outdoor PM2.5 and size distribution measurements were made in each of the study homes over weeklong periods. Data for nighttime, nonsource periods were used to quantify infiltration factors for PM2.5 as well as for 17 discrete particle size intervals between 0.02 and 10 mum. Infiltration factors for PM2.5 exhibited large intra- and interhome variability, which was attributed to seasonal effects and home dynamics. As expected, minimum infiltration factors were observed for ultrafine and coarse particles. A physical-statistical model was-used. to estimate size-specific penetration efficiencies and deposition rates for these study homes. Our data show that the penetration efficiency depends on particle size, as well as home characteristics. These results provide new insight on the protective role of the building shell in reducing indoor exposures to ambient particles, especially for tighter (e.g., winterized) homes and for particles with diameters greater than 1 mum.
引用
收藏
页码:2089 / 2099
页数:11
相关论文
共 43 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[3]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[4]   INDOOR-OUTDOOR RELATIONSHIPS FOR AIRBORNE PARTICULATE MATTER OF OUTDOOR ORIGIN [J].
ALZONA, J ;
COHEN, BL ;
RUDOLPH, H ;
JOW, HN ;
FROHLIGER, JO .
ATMOSPHERIC ENVIRONMENT, 1979, 13 (01) :55-60
[5]  
[Anonymous], [No title captured]
[6]  
[Anonymous], 1996, AIR QUAL CRIT PART M
[7]   TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations [J].
Ayers, GP ;
Keywood, MD ;
Gras, JL .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (22) :3717-3721
[8]  
BYRNE MA, 1992, J AEROSOL SCI, V23, pS543
[9]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[10]   INDOOR-OUTDOOR RELATIONSHIPS OF RESPIRABLE SULFATES AND PARTICLES [J].
DOCKERY, DW ;
SPENGLER, JD .
ATMOSPHERIC ENVIRONMENT, 1981, 15 (03) :335-343