The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review

被引:95
作者
Ameloot, Koen [1 ,2 ]
Palmers, Pieter-Jan [1 ,2 ]
Malbrain, Manu L. N. G. [3 ,4 ]
机构
[1] Univ Hosp Leuven, Dept Cardiol, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Intens Care, Leuven, Belgium
[3] ZNA Stuivenberg, Ziekenhuis Netwerk Antwerpen, Dept Intens Care, B-2060 Antwerp, Belgium
[4] ZNA Stuivenberg, Ziekenhuis Netwerk Antwerpen, Dept High Care Burn Unit, B-2060 Antwerp, Belgium
关键词
blood pressure; cardiac output; finger cuff; hemodynamic monitoring; noninvasive; thermodilution; CONTINUOUS ARTERIAL-PRESSURE; CRITICALLY-ILL PATIENTS; BLOOD-PRESSURE; FLUID RESPONSIVENESS; NEXFIN; THERMODILUTION; VALIDATION; DEVICE; INDEX; FLOW;
D O I
10.1097/MCC.0000000000000198
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review The present review aims to summarize literature on the accuracy of the finger cuff method to measure cardiac output (CO) and blood pressure, its ability to track hemodynamic changes, and to predict fluid responsiveness. Recent findings Finger cuff is an easy-to-use hemodynamic monitoring technique. Different devices are currently available, which provide continuous arterial blood pressure (Finapress), whereas only ClearSight (previously known as Nexfin; BMEYE) provides an estimate of CO. In most studies, the criteria for clinical interchangeability (for CO) were not met, when compared with the currently used invasive monitoring systems such as uncalibrated CO via a radial artery line, and calibrated CO either via a pulmonary artery catheter or a femoral artery catheter connected to the PiCCO (Pulsion Medical Systems) or VolumeView (Edwards Lifesciences) devices. In particular, ClearSight obtained CO seems to be less accurate in patients with a low CO. However, in most patients, ClearSight is able to track hemodynamic changes induced by a fluid challenge or passive leg raising test. We will discuss in this review the relevant literature with regard to validation of the finger cuff technique for both arterial blood pressure and CO. Summary The finger cuff method provides a reasonable estimate of CO and blood pressure, which does not meet the criteria for clinical interchangeability with the currently used invasive devices.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 34 条
[1]  
Ameloot K, 2014, MINERVA ANESTESIOL, V80, P1294
[2]   Nexfin Noninvasive Continuous Hemodynamic Monitoring: Validation against Continuous Pulse Contour and Intermittent Transpulmonary Thermodilution Derived Cardiac Output in Critically Ill Patients [J].
Ameloot, Koen ;
Van De Vijver, Katrijn ;
Broch, Ole ;
Van Regenmortel, Niels ;
De Laet, Inneke ;
Schoonheydt, Karen ;
Dits, Hilde ;
Bein, Berthold ;
Malbrain, Andmanu L. N. G. .
SCIENTIFIC WORLD JOURNAL, 2013,
[3]  
ANSI/AAMI, 2002, AM NAT STAND MAN EL
[4]   Complications related to less-invasive haemodynamic monitoring [J].
Belda, F. J. ;
Aguilar, G. ;
Teboul, J. L. ;
Pestana, D. ;
Redondo, F. J. ;
Malbrain, M. ;
Luis, J. C. ;
Ramasco, F. ;
Umgelter, A. ;
Wendon, J. ;
Kirov, M. ;
Fernandez-Mondejar, E. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (04) :482-486
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease [J].
Bogert, L. W. J. ;
Wesseling, K. H. ;
Schraa, O. ;
Van Lieshout, E. J. ;
de Mol, B. A. J. M. ;
van Goudoever, J. ;
Westerhof, B. E. ;
van Lieshout, J. J. .
ANAESTHESIA, 2010, 65 (11) :1119-1125
[7]  
Broch O, 2013, MINERVA ANESTESIOL, V79, P248
[8]   A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery [J].
Broch, O. ;
Renner, J. ;
Gruenewald, M. ;
Meybohm, P. ;
Schoettler, J. ;
Caliebe, A. ;
Steinfath, M. ;
Malbrain, M. ;
Bein, B. .
ANAESTHESIA, 2012, 67 (04) :377-383
[9]   Noninvasive Continuous Cardiac Output by the Nexfin Before and After Preload-Modifying Maneuvers: A Comparison with Intermittent Thermodilution Cardiac Output [J].
Bubenek-Turconi, Serban Ion ;
Craciun, Mihaela ;
Miclea, Ion ;
Perel, Azriel .
ANESTHESIA AND ANALGESIA, 2013, 117 (02) :366-372
[10]   Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler [J].
Chen, Guo ;
Meng, Lingzhong ;
Alexander, Brenton ;
Nam Phuong Tran ;
Kain, Zeev N. ;
Cannesson, Maxime .
JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (04) :275-283