Optical biosensor consisting of glutathione-S-transferase for detection of captan

被引:29
作者
Choi, JW
Kim, YK
Song, SY
Lee, IH
Lee, WH
机构
[1] Sogang Univ, Dept Chem Engn, Seoul 100611, South Korea
[2] Hankyong Natl Univ, Dept Chem Engn, Ansung 456749, Kyonggi Do, South Korea
关键词
glutathione-S-transferase; captan; gel entrapment; optical biosensor; 1-chloro-2,4-dinitrobenzene; glutathione;
D O I
10.1016/S0956-5663(03)00124-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The optical biosensor consisting of a glutathione-S-transferase (GST)-immobilized gel film was developed to detect captan in contaminated water. The sensing scheme was based on the decrease of yellow product, s-(2,4-dinitrobenzene) gluththione, produced from substrates, 1-chloro-2,4-dinitrobenzene (CDNB) and glutathione (GSH), due to the inhibition of GST reaction by captan. Absorbance of the product as the output of enzyme reaction was detected and the light was guided through the optical fibers. The enzyme reactor of the sensor system was fabricated by the gel entrapment technique for the immobilized GST film. The immobilized GST had the maximum activity at pH 6.5. The optimal concentrations of substrates were determined with 1 mM for both of CDNB and GSH. The optimum concentration of enzyme was also determined with 100 mug/ml. The activity of immobilized enzyme was fairly sustained during 30 days. The proposed biosensor could successfully detect the captan up to 2 ppm and the response time to steady signal was about 15 min. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1461 / 1466
页数:6
相关论文
共 18 条
[1]   HEAT-STABLE LANGMUIR-BLODGETT-FILM OF GLUTATHIONE-S-TRANSFERASE [J].
ANTOLINI, F ;
PADDEU, S ;
NICOLINI, C .
LANGMUIR, 1995, 11 (07) :2719-2725
[2]   FIBEROPTIC EVANESCENT-WAVE SENSING OF ANTIGEN-ANTIBODY BINDING [J].
CAROME, EF ;
COGHLAN, GA ;
SUKENIK, CN ;
ZULL, JE .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 14 (1-3) :732-733
[3]   Optical organophosphorus biosensor consisting of acetyleholinesterase/viologen hetero Langmuir- Blodgett film [J].
Choi, JW ;
Kim, YK ;
Lee, IH ;
Min, JH ;
Lee, WH .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :937-943
[4]   Interaction of glutathione transferase P1-1 with captan and captafol [J].
DiIlio, C ;
Sacchetta, P ;
Angelucci, S ;
Bucciarelli, T ;
Pennelli, A ;
Mazzetti, AP ;
LoBello, M ;
Aceto, A .
BIOCHEMICAL PHARMACOLOGY, 1996, 52 (01) :43-48
[5]  
Hansson LO, 1999, PROTEIN SCI, V8, P2742
[6]   Direct surface analysis of pesticides on soil, leaves, grass, and stainless steel by static secondary ion mass spectrometry [J].
Ingram, JC ;
Groenewold, GS ;
Appelhans, AD ;
Delmore, JE ;
Olson, JE ;
Miller, DL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (02) :402-408
[7]   FIBEROPTIC CHEMICAL SENSORS OFFER A REALISTIC SOLUTION TO ENVIRONMENTAL MONITORING NEEDS [J].
KLAINER, SM ;
THOMAS, JR ;
FRANCIS, JC .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :81-86
[8]   Seed treatment using pre-infiltration and biocontrol agents to reduce damping-off of corn caused by species of Pythium and Fusarium [J].
Mao, W ;
Lumsden, RD ;
Lewis, JA ;
Hebbar, PK .
PLANT DISEASE, 1998, 82 (03) :294-299
[9]  
Martens DA, 1997, PESTIC SCI, V49, P344, DOI 10.1002/(SICI)1096-9063(199704)49:4&lt
[10]  
344::AID-PS538&gt