Application of a Proposed Algorithm to Cesarean Deliveries for Nonreassuring Fetal Heart Rate Tracing

被引:1
作者
Berger, Dana Senderoff [1 ]
Crosland, Adam [1 ]
Newman, Rachel [1 ]
Bosse, Bradley [1 ]
Makhoul, Joshua [1 ]
Chan, Kenneth [2 ]
Seet, Emily L. [2 ]
机构
[1] Univ Calif Irvine, Dept Obstet & Gynecol, Orange, CA 92668 USA
[2] Long Beach Mem Miller Childrens & Womens Hosp, Dept Obstet & Gynecol, Long Beach, CA USA
关键词
nonreassuring fetal heart rate tracing; Category II fetal heart rate tracing; cesarean delivery; intrapartum fetal heart rate; acidosis; fetal distress;
D O I
10.1055/s-0041-1739412
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives The aim of the study is to evaluate how current management of Category II fetal heart rate tracings compares with that suggested by a published algorithm and whether these differences lead to disparate neonatal outcomes. Study Design This is a retrospective observational study from the resident service at an academic-community tertiary care center from 2013 to 2018. We reviewed archived fetal heart rate tracings from patients with cesarean delivery performed for nonreassuring fetal heart rate tracing and interpreted tracings against the algorithm. We assigned tracings to one of three categories: Group A-consistent; Group B-inconsistent too early (algorithm permits the patient to labor longer); Group C-inconsistent too late (algorithm suggests performing the cesarean delivery sooner). Maternal demographics, features of labor, and neonatal outcomes were compared. Results Of the 110 cases, 27 (24.5%) had a cesarean delivery performed in group A, 49 (44.5%) in group B, and 34 (30.9%) in group C. Baseline characteristics were similar. Of the 49 in group B, 46 (93.9%) violated the algorithm at the same branchpoint. In group C, cesarean deliveries would have been performed on average 244 minutes earlier had the algorithm been used. Neonatal outcomes were not significantly different among the groups, including 5-minute Apgar <7, pH <7.1, and NICU admit. Conclusion Our retrospective application of the algorithm showed that 44.5% of patients who have cesarean delivery for nonreassuring fetal heart rate tracing may be able to labor longer and that violation at a common decision point on the algorithm (moderate variability or accelerations, but a lack of recurrent decelerations) is responsible for nearly all such cesarean deliveries. More studies are needed to evaluate if cesarean delivery rates for nonreassuring fetal heart rate tracing can be reduced without impacting neonatal outcomes using the algorithm.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 12 条
  • [1] [Anonymous], 2014, Obstet Gynecol, V123, P693, DOI 10.1097/01.AOG.0000444441.04111.1d
  • [2] [Anonymous], 1987, Int J Gynecol Obstet
  • [3] Indications Contributing to the Increasing Cesarean Delivery Rate
    Barber, Emma L.
    Lundsberg, Lisbet S.
    Belanger, Kathleen
    Pettker, Christian M.
    Funai, Edmund F.
    Illuzzi, Jessica L.
    [J]. OBSTETRICS AND GYNECOLOGY, 2011, 118 (01) : 29 - 38
  • [4] Birth Prevalence of Cerebral Palsy: A Population-Based Study
    Braun, Kim Van Naarden
    Doernberg, Nancy
    Schieve, Laura
    Christensen, Deborah
    Goodman, Alyson
    Yeargin-Allsopp, Marshalyn
    [J]. PEDIATRICS, 2016, 137 (01)
  • [5] A prospective cohort study of fetal heart rate monitoring: deceleration area is predictive of fetal acidemia
    Cahill, Alison G.
    Tuuli, Methodius G.
    Stout, Molly J.
    Lopez, Julia D.
    Macones, George A.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (05) : 523.e1 - 523.e12
  • [6] Cahill AG, 2009, OBSTET GYNECOL, V114, P124, DOI [10.1097/AOG.0b013e3181a99def, 10.1097/AOG.0b013e3181aef106]
  • [7] The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia
    Clark, Steven L.
    Hamilton, Emily F.
    Garite, Thomas J.
    Timmins, Audra
    Warrick, Philip A.
    Smith, Samuel
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (02) : 163.e1 - 163.e6
  • [8] Intrapartum management of category II fetal heart rate tracings: towards standardization of care
    Clark, Steven L.
    Nageotte, Michael P.
    Garite, Thomas J.
    Freeman, Roger K.
    Miller, David A.
    Simpson, Kathleen R.
    Belfort, Michael A.
    Dildy, Gary A.
    Parer, Julian T.
    Berkowitz, Richard L.
    D'Alton, Mary
    Rouse, Dwight J.
    Gilstrap, Larry C.
    Vintzileos, Anthony M.
    van Dorsten, J. Peter
    Boehm, Frank H.
    Miller, Lisa A.
    Hankins, Gary D. V.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 209 (02) : 89 - 97
  • [9] The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring - Update on definitions, interpretation, and research guidelines
    Macones, George A.
    Hankins, Gary D. V.
    Spong, Catherine Y.
    Hauth, John
    Moore, Thomas
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 112 (03) : 661 - 666
  • [10] Parer JT, 1997, AM J OBSTET GYNECOL, V177, P1385