关键词
acute coronary syndromes; acute myocardial infarction; diagnosis; high sensitivity; sensitivity and specificity; troponins; ACUTE CORONARY SYNDROMES; I ASSAY; EARLY-DIAGNOSIS; VALIDATION; GUIDELINES;
D O I
10.1016/j.jacc.2011.06.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This paper sought to evaluate whether high sensitivity troponin (hs-cTnT) can immediately exclude acute myocardial infarction (AMI) at a novel 'rule out' cut-off. Background Subgroup analysis of recent evidence suggests that undetectable hs-cTnT may exclude AMI at presentation. Methods In a cohort study, we prospectively enrolled patients with chest pain, evaluating them with standard troponin T and testing for hs-cTnT (Roche Diagnostics, Basel, Switzerland) at presentation. The primary outcome was a diagnosis of AMI. We also followed up patients for adverse events within 6 months. After subsequent clinical implementation of hs-cTnT, we again evaluated whether initially undetectable hs-cTnT ruled out a subsequent rise. Results Of 703 patients in the cohort study, 130 (18.5%) had AMI, none of whom initially had undetectable hs-cTnT (sensitivity: 100.0%, 95% confidence interval [CI]: 95.1% to 100.0%, negative predictive value: 100.0%, 95% CI: 98.1% to 100.0%). This strategy would rule out AMI in 27.7% of patients, 2 (1.0%) of whom died or had AMI within 6 months (1 periprocedural AMI, 1 noncardiac death). We evaluated this approach in an additional 915 patients in clinical practice. Only 1 patient (0.6%) with initially undetectable hs-cTnT had subsequent elevation (to 17 ng/l), giving a sensitivity of 99.8% (95% CI: 99.1% to 100.0%) and a negative predictive value of 99.4% (95% CI: 96.6% to 100.0%). Conclusions Undetectable hs-cTnT at presentation has very high negative predictive value, which may be considered to rule out AMI, identifying patients at low risk of adverse events. Pending further validation, this strategy may reduce the need for serial testing and empirical treatment, enabling earlier reassurance for patients and fewer unnecessary evaluations and hospital admissions. (J Am Coll Cardiol 2011;58:1332-9) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:1333 / 1339
页数:7
相关论文
共 50 条
  • [1] Rapid Exclusion of Acute Myocardial Infarction in Patients With Undetectable Troponin Using a High-Sensitivity Assay (vol 58, pg 1332, 2011)
    Body, R.
    Carley, S.
    McDowell, G.
    Jaffe, A. S.
    France, M.
    Cruickshank, K.
    Wibberley, C.
    Nuttall, M.
    Mackway-Jones, K.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (12) : 1122 - 1122
  • [2] Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a sensitive troponin I assay
    Body, Richard
    Burrows, Gillian
    Carley, Simon
    Lewis, Philip S.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (05) : 543 - 549
  • [3] Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin
    Gimenez, Maria Rubini
    Hoeller, Rebeca
    Reichlin, Tobias
    Zellweger, Christa
    Twerenbold, Raphael
    Reiter, Miriam
    Moehring, Berit
    Wildi, Karin
    Mosimann, Tamina
    Mueller, Mira
    Meller, Bernadette
    Hochgruber, Thomas
    Ziller, Ronny
    Sou, Seoung Mann
    Murray, Karsten
    Sakarikos, Konstantin
    Ernst, Susanne
    Gea, Joaquim
    Campodarve, Isabel
    Vilaplana, Carles
    Haaf, Philip
    Steuer, Stephan
    Minners, Jan
    Osswald, Stefan
    Mueller, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3896 - 3901
  • [4] Serial high-sensitivity troponin measurements for the rapid exclusion of acute myocardial infarction in low-risk patients
    Dawson, Charlotte
    Benger, Jonathan R.
    Bayly, Graham
    EMERGENCY MEDICINE JOURNAL, 2013, 30 (07) : 593 - 594
  • [5] External validation of a rapid algorithm using high-sensitivity troponin assay results for evaluating patients with suspected acute myocardial infarction
    Cullen, Louise
    Greenslade, Jaimi H.
    Stephensen, Laura
    Ranasinghe, Isuru
    Gaikwad, Niranjan
    Bayat, Maryam Khorramshahi
    Mahmoodi, Ehsan
    Than, Martin
    Apple, Fred
    Parsonage, William
    EMERGENCY MEDICINE JOURNAL, 2024, 41 (05) : 313 - 319
  • [6] Diagnosis of Acute Myocardial Infarction in Hemodialysis Patients With High-Sensitivity Cardiac Troponin T Assay
    Huang, Hua-Lan
    Zhu, Shuai
    Wang, Wei-Qing
    Nie, Xin
    Shi, Ying-Ying
    He, Yong
    Song, Hao-Lan
    Miao, Qiang
    Fu, Ping
    Wang, Lan-Lan
    Li, Gui-Xing
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2016, 140 (01) : 75 - 80
  • [7] Release kinetics of troponin T measured with a high-sensitivity assay in patients with acute myocardial infarction
    Liebetrau, Christoph
    Nef, Holger
    Szardien, Sebastian
    Willmer, Matthias
    Rixe, Johannes
    Troidl, Christian
    Hoffmann, Jedrzej
    Rolf, Andreas
    Hamm, Christian
    Moellmann, Helge
    CIRCULATION, 2012, 125 (19) : E697 - E697
  • [8] Validation of a rapid diagnostic algorithm for diagnosis of myocardial infarction using a high-sensitivity cardiac troponin assay
    Lehmacher, J.
    Toprak, B.
    Soerensen, N. A.
    Kellen, R. Bei Der
    Hartikainen, T. S.
    Haller, P. M.
    Schock, A.
    Twerenbold, R.
    Zeller, T.
    Blankenberg, S.
    Westermann, D.
    Neumann, J. T.
    EUROPEAN HEART JOURNAL, 2022, 43 : 1355 - 1355
  • [9] Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation
    Greenslade, Jaimi
    Cho, Elizabeth
    Van Hise, Christopher
    Hawkins, Tracey
    Parsonage, William
    Ungerer, Jacobus
    Tate, Jillian
    Pretorius, Carel
    Than, Martin
    Cullen, Louise
    CLINICAL CHEMISTRY, 2018, 64 (05) : 820 - 829
  • [10] Is a Single High-Sensitivity Troponin T Assay Accurate for the Detection of Acute Myocardial Infarction?
    Kirschner, Jonathan
    Zahn, Greg
    ANNALS OF EMERGENCY MEDICINE, 2016, 68 (03) : 295 - 297