Validation of the COTENP Code: A Steady-State Thermal-Hydraulic Analysis Code for Nuclear Reactors with Plate Type Fuel Assemblies

被引:5
作者
Castellanos-Gonzalez, Duvan A. [1 ]
Losada Moreira, Joao Manoel [1 ]
Maiorino, Jose Rubens [1 ]
Carajilescov, Pedro [1 ]
机构
[1] Univ Fed ABC, Ctr Engn Modelagem & Ciencias Sociais Aplicadas, Av Estados 5001, BR-09210508 Santo Andre, SP, Brazil
关键词
SUBCHANNEL ANALYSIS; FLOW; BENCHMARK; ONSET;
D O I
10.1155/2018/9874196
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This article presents the validation of the Code for Thermal-hydraulic Evaluation of Nuclear Reactors with Plate Type Fuels (COTENP), a subchannel code which performs steady-state thermal-hydraulic analysis of nuclear reactors with plate type fuel assemblies operating with the coolant at low pressure levels. The code is suitable for design analysis of research, test, and multipurpose reactors. To solve the conservation equations for mass, momentum, and energy, we adopt the subchannel and control volume methods based on fuel assembly geometric data and thermal-hydraulic conditions. We consider the chain or cascade method in two steps to facilitate the analysis of whole core. In the first step, we divide the core into channels with dimensions equivalent to that of the fuel assembly and identify the assembly with largest enthalpy rise as the hot assembly. In the second step, we divide the hot fuel assembly into subchannels with size equivalent to one actual coolant channel and similarly identify the hot subchannel. The code utilizes the homogenous equilibrium model for two-phase flow treatment and the balanced drop pressure approach for the flow rate determination. The code results include detailed information such as core pressure drop, mass flow rate distribution, coolant, cladding and centerline fuel temperatures, coolant quality, local heat flux, and results regarding onset of nucleate boiling and departure of nucleate boiling. To validate the COTENP code, we considered experimental data from the Brazilian IEA-R1 research reactor and calculated data from the Chinese CARR multipurpose reactor. The mean relative discrepancies for the coolant distribution were below 5%, for the coolant velocity were 1.5%, and for the pressure drop were below 10.7%. The latter discrepancy can be partially justified due to lack of information to adequately model the IEA-R1 experiment and CARR reactor. The results show that the COTENP code is sufficiently accurate to perform steady-state thermal-hydraulic design analyses for reactors with plate type fuel assemblies.
引用
收藏
页数:17
相关论文
共 36 条
[1]   Onset of Nucleate Boiling for subcooled flow through a one-side heated narrow rectangular channel [J].
Al-Yahia, Omar S. ;
Jo, Daeseong .
ANNALS OF NUCLEAR ENERGY, 2017, 109 :30-40
[2]  
Chao J., 1992, NESC9978 NUCL EN AG
[3]  
Chapra S., 2006, Metodos Numericos para Ingenieros, VFifth
[4]  
Cuervo G., 2007, THESIS
[5]  
Duderstadt J.J., 1991, Nuclear Reactor Analysis
[6]  
El-Wakil M.M., 1971, Nuclear Heat Transport
[7]  
Gong D., 2015, SCI TECHNOLOGY NUCL, V2015, P13, DOI 10. 1155/2015/198654
[8]   International benchmark study of advanced thermal hydraulic safety analysis codes against measurements on IEA-R1 research reactor [J].
Hainoun, A. ;
Doval, A. ;
Umbehaun, P. ;
Chatzidakis, S. ;
Ghazi, N. ;
Park, S. ;
Mladin, M. ;
Shokr, A. .
NUCLEAR ENGINEERING AND DESIGN, 2014, 280 :233-250
[9]   Safety analysis of the IAEA reference research reactor during loss of flow accident using the code MERSAT [J].
Hainoun, A. ;
Ghazi, N. ;
Abdul-Moaiz, B. Mansour .
NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (05) :1132-1138
[10]   RELAP5/3.2 assessment against low pressure onset of flow instability in parallel heated channels [J].
Hamidouche, Tewfik ;
Bousbia-salah, Anis .
ANNALS OF NUCLEAR ENERGY, 2006, 33 (06) :510-520