Calibration and Limits of Camera-Based Fluorescence Correlation Spectroscopy: A Supported Lipid Bilayer Study

被引:54
|
作者
Bag, Nirmalya [1 ,2 ,3 ]
Sankaran, Jagadish [1 ,2 ,3 ,4 ,5 ]
Paul, Alexandra [1 ,2 ,3 ,6 ]
Kraut, Rachel S. [5 ]
Wohland, Thorsten [1 ,2 ,3 ,4 ]
机构
[1] Natl Univ Singapore, Dept Biol Sci, Singapore 117546, Singapore
[2] Natl Univ Singapore, Dept Chem, Singapore 117546, Singapore
[3] Natl Univ Singapore, NUS Ctr Bioimaging Sci, Singapore 117546, Singapore
[4] Natl Univ Singapore, Singapore MIT Alliance, Singapore 117576, Singapore
[5] Nanyang Technol Univ, Sch Biol Sci, Singapore 637551, Singapore
[6] Univ Saarland, Dept Biophys Chem, D-66123 Saarbrucken, Germany
关键词
fluorescence spectroscopy; membrane; multiplexing; point spread function; total internal reflection; INTERNAL-REFLECTION FLUORESCENCE; IMAGE CORRELATION SPECTROSCOPY; CROSS-CORRELATION SPECTROSCOPY; EXHIBITING MODEL MEMBRANES; SINGLE-PARTICLE TRACKING; COUPLED-DEVICE CAMERA; CORRELATION MICROSCOPY; DIFFUSION LAWS; DYNAMICS; CHOLESTEROL;
D O I
10.1002/cphc.201200032
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Camera-based fluorescence correlation spectroscopy (FCS) approaches allow the measurement of thousands of contiguous points yielding excellent statistics and details of sample structure. Imaging total internal reflection FCS (ITIR-FCS) provides these measurements on lipid membranes. Herein, we determine the influence of the point spread function (PSF) of the optical system, the laser power used, and the time resolution of the camera on the accuracy of diffusion coefficient and concentration measurements. We demonstrate that the PSF can be accurately determined by ITIR-FCS and that the laser power and time resolution can be varied over a wide range with limited influence on the measurement of the diffusion coefficient whereas the concentration measurements are sensitive to changes in the measurement parameters. One advantage of ITIR-FCS is that the measurement of the PSF has to be performed only once for a given optical setup, in contrast to confocal FCS in which calibrations have to be performed at least once per measurement day. Using optimized experimental conditions we provide diffusion coefficients for over ten different lipid membranes consisting of one, two and three constituents, measured in over 200000 individual correlation functions. Using software binning and thus the inherent advantage of ITIR-FCS of providing multiple observation areas in a single measurement we test the FCS diffusion law and show how they can be complemented by the local information provided by the difference in cross-correlation functions (?CCF). With the determination of the PSF by ITIR-FCS and the optimization of measurement conditions ITIR-FCS becomes a calibration-free method. This allows us to provide measurements of absolute diffusion coefficients for bilayers with different compositions, which were stable over many different bilayer preparations over a time of at least one year, using a single PSF calibration.
引用
收藏
页码:2784 / 2794
页数:11
相关论文
共 50 条
  • [41] Determination of the fluorescence labels location in lipid bilayer based on fluorescence quenching
    Pentak, D.
    Zawada, Z.
    Szkudlarek, A.
    Ploch, A.
    Maciazek-Jurczyk, M.
    JOURNAL OF MOLECULAR LIQUIDS, 2018, 256 : 84 - 89
  • [42] Microcavity-Supported Lipid Bilayers; Evaluation of Drug-Lipid Membrane Interactions by Electrochemical Impedance and Fluorescence Correlation Spectroscopy
    Ramadurai, Sivaramakrishnan
    Sarangi, Nirod Kumar
    Maher, Sean
    MacConnell, Nicola
    Bond, Alan M.
    McDaid, Dennis
    Flynn, Damien
    Keyes, Tia E.
    LANGMUIR, 2019, 35 (24) : 8095 - 8109
  • [43] Fluorescence study on aggregated lysozyme and lipid bilayer interactions
    Trusova, Valeriya M.
    Gorbenko, Galyna P.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2012, 113 : 51 - 55
  • [44] Polymer Dynamics, Fluorescence Correlation Spectroscopy, and the Limits of Optical Resolution
    Enderlein, Joerg
    PHYSICAL REVIEW LETTERS, 2012, 108 (10)
  • [45] In vivo ultrasound-switchable fluorescence imaging using a camera-based system
    Yu, Shuai
    Yao, Tingfeng
    Liu, Yang
    Yuan, Baohong
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (03): : 1517 - 1538
  • [46] A Robust Camera-Based Method for Optical Distortion Calibration of Head-Mounted Displays
    Lee, Sangyoon
    Hua, Hong
    JOURNAL OF DISPLAY TECHNOLOGY, 2015, 11 (10): : 845 - 853
  • [47] Camera-based Color Calibration Method for Multiple Flat-panel Display System
    Jung, June-Young
    Park, Seung
    Yoo, Cheol-Hwan
    Shin, Yong-Goo
    Ko, Sung-Jea
    2015 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2015, : 90 - 91
  • [48] Design and Calibration of a Novel Camera-Based Bio-Inspired Polarization Navigation Sensor
    Fan, Chen
    Hu, Xiaoping
    Lian, Junxiang
    Zhang, Lilian
    He, Xiaofeng
    IEEE SENSORS JOURNAL, 2016, 16 (10) : 3640 - 3648
  • [49] Local dynamics in topographic imaging of lipid domains in supported bilayers: Atomic force microscopy and fluorescence correlation spectroscopy
    Burns, AR
    Frankel, DJ
    Buranda, T
    BIOPHYSICAL JOURNAL, 2005, 88 (01) : 208A - 208A
  • [50] TIR-Raman spectroscopy as a technique for studying supported lipid bilayer formation
    Churchwell, John
    Bain, Colin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245