Calibration and Limits of Camera-Based Fluorescence Correlation Spectroscopy: A Supported Lipid Bilayer Study

被引:54
|
作者
Bag, Nirmalya [1 ,2 ,3 ]
Sankaran, Jagadish [1 ,2 ,3 ,4 ,5 ]
Paul, Alexandra [1 ,2 ,3 ,6 ]
Kraut, Rachel S. [5 ]
Wohland, Thorsten [1 ,2 ,3 ,4 ]
机构
[1] Natl Univ Singapore, Dept Biol Sci, Singapore 117546, Singapore
[2] Natl Univ Singapore, Dept Chem, Singapore 117546, Singapore
[3] Natl Univ Singapore, NUS Ctr Bioimaging Sci, Singapore 117546, Singapore
[4] Natl Univ Singapore, Singapore MIT Alliance, Singapore 117576, Singapore
[5] Nanyang Technol Univ, Sch Biol Sci, Singapore 637551, Singapore
[6] Univ Saarland, Dept Biophys Chem, D-66123 Saarbrucken, Germany
关键词
fluorescence spectroscopy; membrane; multiplexing; point spread function; total internal reflection; INTERNAL-REFLECTION FLUORESCENCE; IMAGE CORRELATION SPECTROSCOPY; CROSS-CORRELATION SPECTROSCOPY; EXHIBITING MODEL MEMBRANES; SINGLE-PARTICLE TRACKING; COUPLED-DEVICE CAMERA; CORRELATION MICROSCOPY; DIFFUSION LAWS; DYNAMICS; CHOLESTEROL;
D O I
10.1002/cphc.201200032
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Camera-based fluorescence correlation spectroscopy (FCS) approaches allow the measurement of thousands of contiguous points yielding excellent statistics and details of sample structure. Imaging total internal reflection FCS (ITIR-FCS) provides these measurements on lipid membranes. Herein, we determine the influence of the point spread function (PSF) of the optical system, the laser power used, and the time resolution of the camera on the accuracy of diffusion coefficient and concentration measurements. We demonstrate that the PSF can be accurately determined by ITIR-FCS and that the laser power and time resolution can be varied over a wide range with limited influence on the measurement of the diffusion coefficient whereas the concentration measurements are sensitive to changes in the measurement parameters. One advantage of ITIR-FCS is that the measurement of the PSF has to be performed only once for a given optical setup, in contrast to confocal FCS in which calibrations have to be performed at least once per measurement day. Using optimized experimental conditions we provide diffusion coefficients for over ten different lipid membranes consisting of one, two and three constituents, measured in over 200000 individual correlation functions. Using software binning and thus the inherent advantage of ITIR-FCS of providing multiple observation areas in a single measurement we test the FCS diffusion law and show how they can be complemented by the local information provided by the difference in cross-correlation functions (?CCF). With the determination of the PSF by ITIR-FCS and the optimization of measurement conditions ITIR-FCS becomes a calibration-free method. This allows us to provide measurements of absolute diffusion coefficients for bilayers with different compositions, which were stable over many different bilayer preparations over a time of at least one year, using a single PSF calibration.
引用
收藏
页码:2784 / 2794
页数:11
相关论文
共 50 条
  • [1] Accuracy and Precision in Camera-Based Fluorescence Correlation Spectroscopy Measurements
    Sankaran, Jagadish
    Bag, Nirmalya
    Kraut, Rachel Susan
    Wohland, Thorsten
    ANALYTICAL CHEMISTRY, 2013, 85 (08) : 3948 - 3954
  • [2] Fluorescence correlation and lifetime correlation spectroscopy applied to the study of supported lipid bilayer models of the cell membrane
    Basit, Hajra
    Lopez, Sergio G.
    Keyes, Tia E.
    METHODS, 2014, 68 (02) : 286 - 299
  • [3] FLUORESCENCE CORRELATION SPECTROSCOPY OF LIPID BILAYER MEMBRANES
    HERBERT, TJ
    ELSON, EL
    WEBB, WW
    FEDERATION PROCEEDINGS, 1974, 33 (05) : 1303 - 1303
  • [4] Breaking the Concentration Limit in Fluorescence Fluctuation Spectroscopy with Camera-Based Detection
    Huang, Yu-Kai
    Hedde, Per Niklas
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (17)
  • [5] Characterization of lipid bilayer phases by confocal microscopy and fluorescence correlation spectroscopy
    Korlach, J
    Schwille, P
    Webb, WW
    Feigenson, GW
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (15) : 8461 - 8466
  • [6] An evolutionary approach to camera-based projector calibration
    Johnson, Clayton Matthew
    Bhat, Anu
    Thibault, William C.
    GECCO 2006: GENETIC AND EVOLUTIONARY COMPUTATION CONFERENCE, VOL 1 AND 2, 2006, : 1871 - +
  • [7] Raman Spectroscopy of Supported Lipid Bilayer Nanoparticles
    Ahmed, Selver
    Wunder, Stephanie L.
    Nickolov, Zhorro S.
    SPECTROSCOPY, 2011, : 8 - 20
  • [8] Quantifying the Diffusion of Lipids in the Proximal/Distal Leaflets of a Supported Lipid Bilayer by Two-Dimensional Fluorescence Lifetime Correlation Spectroscopy
    Otosu, Takuhiro
    Yamaguchi, Shoichi
    JOURNAL OF PHYSICAL CHEMISTRY B, 2018, 122 (45): : 10315 - 10319
  • [9] Camera-based calibration techniques for seamless multiprojector displays
    Brown, M
    Majumder, A
    Yang, RG
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2005, 11 (02) : 193 - 206
  • [10] Auto calibration for multiple camera-based surveillance system
    Kwon, O
    Kim, S
    Shin, J
    Paik, J
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING 2005, PTS 1-4, 2005, 5960 : 1371 - 1380