What design factors influence wear behavior at the bearing surfaces in total joint replacements?

被引:7
作者
Brown, Thomas D. [1 ]
Bartel, Donald L. [2 ,3 ]
机构
[1] Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
[2] Cornell Univ, Ithaca, NY USA
[3] Hosp Special Surg, New York, NY 10021 USA
关键词
D O I
10.5435/00124635-200800001-00020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bearing surface wear in total joint replacements arises from local stresses that exceed the mechanical strength of the articulating materials. Because both the tensile/compressive principal stresses and maximum shear stress near the bearing surface increase when contact stresses increase, minimizing contact stresses has been a central design goal, especially in total knees. Wear rates increase with factors such as increased sliding distance in metal-on-polyethylene bearings, or suboptimal fluid film lubrication in the case of hard-on-hard total hip implants. These factors in turn depend directly on implant design. Advanced preclinical assessment technologies such as laboratory physical simulators and finite element analyses have provided means by which the dependence of wear rate on mechanical design factors can be quantified. However, untoward complexities occurring in vivo, such as impingement or third-body challenge, can appreciably compromise wear performance even for implants that arc: well-designed in terms of bearing surface stress minimization.
引用
收藏
页码:S101 / S106
页数:6
相关论文
共 19 条
[1]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[2]  
BARTEL DL, 1995, CLIN ORTHOP RELAT R, P76
[3]   THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[4]   Molecular chain stretch is a multiaxial failure criterion for conventional and highly crosslinked UHMWPE [J].
Bergström, JS ;
Rimnac, CM ;
Kurtz, SM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (02) :367-375
[5]   Robust optimization of total joint replacements incorporating environmental variables [J].
Chang, PB ;
Williams, BJ ;
Santner, TJ ;
Notz, WI ;
Bartel, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (03) :304-310
[6]   Design and analysis of robust total joint replacements: Finite element model experiments with environmental variables [J].
Chang, PB ;
Williams, BJ ;
Bhalla, KSB ;
Belknap, TW ;
Santner, TJ ;
Notz, WI ;
Bartel, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03) :239-246
[7]   Metal-on-metal hip joint tribology [J].
Dowson, D ;
Jin, ZM .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :107-118
[8]   Surface damage to an Oxinium femoral head prosthesis after dislocation [J].
Evangelista, G. T. ;
Fulkerson, E. ;
Kummer, E. ;
Di Cesare, P. E. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04) :535-537
[9]   Presidential guest lecture - Tribology of alternative beatings [J].
Fisher, John ;
Jin, Zhongmin ;
Tipper, Joanne ;
Stone, Martin ;
Ingham, Eileen .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :25-34
[10]   Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes [J].
Kurtz, SM ;
Ochoa, JA ;
Hovey, CB ;
White, CV .
JOURNAL OF BIOMECHANICS, 1999, 32 (09) :967-976