Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model

被引:19
作者
Seeley, Mark A. [1 ]
Fabricant, Peter D. [2 ]
Lawrence, J. Todd R. [3 ]
机构
[1] Geisinger Med Ctr, 100 N Acad Ave, Danville, PA 17821 USA
[2] Hosp Special Surg, 535 E 70th St, New York, NY 10021 USA
[3] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
关键词
FOREARM FRACTURES; RISK-FACTORS; EMERGENCY-MEDICINE; PEDIATRIC FOREARM; CLOSED REDUCTION; CHILDREN; REDISPLACEMENT; SIMULATION; MANIPULATION; EDUCATION;
D O I
10.1007/s11999-017-5336-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Questions/purposes Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. Methods A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the realism of simulation. Eighteen participants consented to participate in the study (eight attending pediatric orthopaedic surgeons, six junior residents, four senior residents). The performances of junior residents (Postgraduate Year [PGY] 1-2), senior residents (PGY 3-5), and attending surgeons were compared using one-way ANOVA with Tukey's-adjusted pairwise comparisons. Results The majority of participants (15 of 18) felt that the model looked, felt, and moved like a human forearm. All participants strongly agreed that the model taught the basic steps of fracture reduction and should be implemented in orthopaedic training. Attending surgeons reduced fractures in less time than junior residents (60 +/- 27 seconds versus 460 +/- 62 seconds; mean difference, 400 seconds; 95% CI, 335-465 seconds; p < 0.001). Residual angulation was greater for junior residents when compared with attending surgeons on AP (7 degrees +/- 5 degrees versus 0.7 degrees +/- 0.9 degrees; mean difference, 6.3 degrees; 95% CI, 3 degrees-11 degrees; p = 0.003) and lateral (27 degrees +/- 7 degrees versus 7 degrees +/- 5 degrees; mean difference, 20 degrees; 95% CI, 13 degrees-27 degrees; p = 0.001) radiographs. Similarly, residual displacement was greater for junior residents than either senior residents (mean difference, 16 mm; 95% CI, 2-34 mm; p = 0.05) or attending surgeons (mean difference, 15 mm; 95% CI, 3-27 mm; p = 0.02) on lateral images. There were no differences identified in secondary performance variables (number of fluoroscopic images, casting time, and cast index) between groups. Conclusions This is the first distal radius fracture reduction model to incorporate an elbow and shoulder and allow quantitative assessment of the fracture reduction. This simulator may be useful in an orthopaedic resident training program to help them reach a defined minimum level of competency. This simulator also could easily be integrated in other accreditation and training programs, including emergency medicine.
引用
收藏
页码:2298 / 2305
页数:8
相关论文
共 25 条
[1]   The role of simulation in developing surgical skills [J].
Akhtar K.S.N. ;
Chen A. ;
Standfield N.J. ;
Gupte C.M. .
Current Reviews in Musculoskeletal Medicine, 2014, 7 (2) :155-160
[2]   Risk factors in redisplacement of distal radial fractures in children [J].
Alemdaroglu, Kadir Bahadir ;
Iltar, Serkan ;
Cimen, Oguzhan ;
Uysal, Mehmet ;
Alagoez, Ender ;
Atlihan, Dogan .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06) :1224-1230
[3]  
Asadollahi S, 2015, J PEDIATR ORTHOPED, V35, P224, DOI 10.1097/BPO.0000000000000239
[4]   Pediatric Distal Radius and Forearm Fractures [J].
Bae, Donald S. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (10) :1911-1923
[5]   Determining content for a simulation-based curriculum in pediatric emergency medicine: results from a national Delphi process [J].
Bank, Ilana ;
Cheng, Adam ;
McLeod, Peter ;
Bhanji, Farhan .
CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2015, 17 (06) :662-669
[6]   Integrating the accreditation council for graduate medical education core competencies into the model of the clinical practice of emergency medicine [J].
Chapman, DM ;
Hayden, S ;
Sanders, AB ;
Binder, LS .
ANNALS OF EMERGENCY MEDICINE, 2004, 43 (06) :756-769
[7]   No time to train the surgeons - More and more reforms result in less and less time for training [J].
Chikwe, J ;
de Souza, AC ;
Pepper, JR .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 328 (7437) :418-419
[8]   ACGME and ABOS Changes for the Orthopaedic Surgery PGY-1 (Intern) Year [J].
Dougherty, Paul J. ;
Marcus, Randall E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (11) :3412-3416
[9]   Development of a Model for Teaching Manipulation of a Distal Radial Fracture [J].
Egan, Ciara ;
Egan, Roisin ;
Curran, Padraig ;
Bryan, Keith ;
Fleming, Patrick .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (05) :433-438
[10]  
Fabricant Peter D, 2013, J Grad Med Educ, V5, P19, DOI 10.4300/JGME-D-12-00081.1